Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Lancer ULTIMA 815LX Undercounter Laboratory Glassware Washer

Fully Tested & Warrantied*
Brand : Lancer
Product Code : SKU 2712BBB GL WASH
Sold Out
⚠

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Lancer ULTIMA 815LX Undercounter Laboratory Glassware Washer – Used and Refurbished

The Lancer ULTIMA 815LX Undercounter Glassware Washer is a high-performance laboratory washer and dryer designed for automated cleaning, rinsing, and drying of reusable laboratory glassware. Featuring a 140-liter (4.9 cu. ft.) stainless steel chamber, two independent washing levels, programmable wash cycles, direct-injection cleaning capabilities, and integrated forced-air drying, the 815LX provides a comprehensive glassware cleaning solution in a compact, space-saving design.

Manufactured by Getinge Lancer, the ULTIMA 815LX is designed for laboratories requiring consistent cleaning performance, flexible rack configurations, and reliable processing of glassware used in research, analytical testing, pharmaceutical development, and quality control.

Unlike basic laboratory glassware washers, the 815LX incorporates heated forced-air chamber drying to reduce residual moisture after washing and rinsing. An optional HEPA-filtered injector drying system is available for more effective drying of narrow-neck glassware when the appropriate accessories are installed.

The washer also features a 3.5-inch color touchscreen, a programmable PROLUX controller, and capacity for up to 40 wash programs, including four preset and 36 user-defined programs.

This Lancer ULTIMA 815LX is offered used and refurbished by American Instrument Exchange. Refurbished equipment is inspected and tested before shipment and includes a 90-day warranty, providing laboratories with a cost-effective alternative to purchasing a new glassware washer.

Key Features

  • Lancer ULTIMA 815LX undercounter laboratory glassware washer and dryer

  • 140-liter (4.9 cu. ft.) stainless steel wash chamber

  • Compact 24-inch-wide design for laboratory casework

  • Two independent washing levels

  • Direct-injection washing with compatible racks and accessories

  • Integrated heated forced-air chamber drying

  • Optional HEPA-filtered injector drying for narrow-neck glassware

  • 3.5-inch color touchscreen interface

  • PROLUX programmable microprocessor controller

  • 40-program capacity: four preset and 36 user-defined programs

  • Maximum wash temperature of 95°C on applicable configurations

  • Maximum wash temperature of 85°C on 120V configurations

  • High-capacity 350 L/min (92 gal/min) recirculation pump

  • Automatic chemical dosing through peristaltic pumps

  • Compatible with purified-water rinsing

  • Approximately 12 liters (3.1 gallons) of water per fill

  • Stainless steel spray arms and wash chamber

  • Self-diagnostic functions and operating alarms

  • Counterbalanced fold-down door for convenient loading

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Lancer ULTIMA 815LX is a programmable laboratory washer and dryer designed to automate the cleaning of reusable glassware and other compatible laboratory equipment.

Manual glassware washing can require substantial technician time, particularly when processing narrow-neck bottles, flasks, graduated cylinders, and vessels with difficult-to-reach interior surfaces.

The 815LX addresses these challenges through controlled wash programs, powerful water circulation, chemical dosing, and interchangeable rack configurations.

Its two-level washing system allows laboratories to accommodate different glassware types within a compact chamber. When equipped with appropriate injection racks, the washer can direct cleaning solution into the interiors of narrow-neck vessels.

The integrated forced-air drying system provides an additional processing stage after washing and rinsing, helping reduce residual moisture and improve turnaround time.

Common Applications

The Lancer ULTIMA 815LX is suitable for cleaning compatible laboratory bottles, beakers, Erlenmeyer flasks, graduated cylinders, test tubes, volumetric glassware, sample preparation containers, and reusable laboratory utensils.

Common applications include pharmaceutical research, biotechnology, analytical chemistry, microbiology, environmental testing, industrial quality control, and academic laboratory operations.

The types of glassware that can be processed depend on the installed racks, injection accessories, selected wash programs, and material compatibility.

Key Specifications

Specification Details
Manufacturer Getinge Lancer
Series ULTIMA
Model 815LX
Equipment Type Undercounter Laboratory Glassware Washer/Dryer
Installation Undercounter; Optional Base Cabinet Configuration
Chamber Capacity 140 L (4.9 cu. ft.)
Exterior Dimensions 24"W × 29.1"D × 33.5"H
Interior Dimensions 21.1"W × 20.5"D × 19.6"H
Chamber Material 304L Stainless Steel
Spray Arms 316L Stainless Steel
Washing Levels 2
Controller PROLUX Programmable Controller
Display 3.5" Color Touchscreen
Wash Programs 4 Preset + 36 User-Defined
Maximum Wash Temperature 95°C on Applicable Configurations
Maximum Temperature, 120V 85°C
Drying System Heated Forced-Air Chamber Drying
Optional Drying HEPA-Filtered Injector Drying
Drying Heater 2.4 kW
Wash Water Heating 6 kW on Applicable Configurations
Recirculation Pump 350 L/min (92 gal/min)
Water Consumption Approximately 12 L (3.1 gal) per Fill
Water Supply Pressure 29–87 psi (200–600 kPa)
Water Supply Cold and Purified/DI Water Connections
Chemical Dosing Automatic Peristaltic Pumps
Noise Level Approximately 60 dB(A) or Less
Net Weight Approximately 187 lb (85 kg)
Electrical Options 120V or 208V, Configuration-Dependent
Electrical Phase Single-Phase or Three-Phase, Depending on Version
Racks and Inserts Verify Included Accessories
Condition Used / Refurbished
Warranty 90 Days

Specifications are based on Getinge Lancer ULTIMA 815LX technical documentation. The exact electrical configuration, included racks, drying accessories, and optional equipment should be verified on the individual refurbished washer.

Ideal Laboratory Types

The Lancer ULTIMA 815LX is well suited to pharmaceutical research laboratories, biotechnology facilities, analytical chemistry departments, molecular biology laboratories, environmental testing facilities, academic research institutions, and industrial quality-control laboratories.

Its compact design is particularly useful for facilities requiring automated glassware cleaning and drying without dedicating substantial floor space to a larger freestanding washer.

Integrated Forced-Air Drying

One of the principal advantages of the ULTIMA 815LX is its integrated forced-air drying system.

After the washing and rinsing stages, heated air circulates through the chamber to help remove residual moisture from compatible glassware.

The manufacturer specifies a 2.4 kW heating and blower system for chamber drying.

This feature can reduce the need for separate drying equipment and help laboratories return cleaned glassware to service more quickly.

Drying performance depends on the selected program, glassware geometry, rack arrangement, and operating conditions.

Optional HEPA-Filtered Injector Drying

The 815LX was also offered with an optional HEPA-filtered injector drying system.

When installed with compatible injection racks, this system can direct filtered heated air into narrow-neck bottles and flasks.

This is particularly useful for vessels that may retain moisture after conventional chamber drying.

The HEPA-filtered injector drying system is an optional feature and should not be assumed included with every 815LX.

Customers should confirm whether this accessory is installed on the refurbished unit before purchase.

Two-Level Direct-Injection Washing

The ULTIMA 815LX supports washing on two independent levels.

With compatible injection racks, cleaning solution can be delivered directly into laboratory bottles, flasks, and other narrow-neck vessels.

This targeted washing action is useful for glassware that may be difficult to clean using external spray coverage alone.

The washer also incorporates stainless steel spray arms for cleaning accessible exterior and interior surfaces.

Interchangeable racks allow the chamber to be configured for different laboratory applications.

PROLUX Touchscreen Controller

The Lancer 815LX ULTIMA features a 3.5-inch color touchscreen interface and PROLUX programmable controller.

The controller supports four preset wash programs and up to 36 user-defined programs.

Operators can configure parameters for prewashing, detergent washing, rinsing, purified-water rinsing, and drying.

The system also includes password-protected programming levels, operating alarms, and self-diagnostic functions.

These capabilities help laboratories establish repeatable cleaning procedures appropriate for their applications.

High-Temperature Washing and Rinsing

The 815LX supports elevated-temperature washing and rinsing.

On applicable electrical configurations, the manufacturer specifies a maximum wash temperature of 95°C.

The 120V version is limited to approximately 85°C.

Elevated-temperature processing can improve removal of certain residues and support appropriately developed cleaning procedures.

However, maximum temperature capability does not automatically establish that a cleaning or disinfection cycle has been validated for a particular laboratory application.

Automatic Detergent and Acid Dosing

The ULTIMA 815LX incorporates automatic peristaltic dosing pumps for compatible cleaning and neutralizing agents.

Automated chemical dosing helps deliver repeatable amounts of detergent and acid during selected program stages.

This can improve cleaning consistency and reduce the need for manual chemical measurement.

Appropriate chemical selection and concentration depend on the glassware materials, residue types, water quality, and cleaning requirements.

The dosing pumps, tubing, and chemical connections should be inspected before operation.

Water Circulation and Cleaning Performance

The 815LX uses a high-capacity recirculation pump rated at approximately 350 liters per minute, equivalent to 92 gallons per minute.

This system delivers wash water through the chamber spray assemblies and compatible injection racks.

The manufacturer specifies approximately 12 liters of fresh water per fill.

The total water consumed during a complete cleaning program depends on the number of washing and rinsing stages selected.

Proper loading, detergent selection, water quality, and rack configuration are important factors in achieving consistent cleaning results.

Purified-Water Rinsing

The Lancer 815LX supports purified or deionized-water rinse stages when connected to an appropriate water supply.

Purified-water rinsing can help reduce mineral deposits and other residues on cleaned laboratory glassware.

This is particularly useful in analytical chemistry, pharmaceutical research, and other applications where residual contamination may affect downstream results.

The laboratory's water supply must meet the manufacturer's pressure, flow, and connection requirements.

Stainless Steel Construction

The ULTIMA 815LX features a 304L stainless steel chamber and door, with 316L stainless steel spray arms.

These materials provide durability and resistance to many cleaning chemicals used in laboratory washing applications.

The chamber and door are insulated to help reduce heat loss and operating noise.

The counterbalanced fold-down door also provides a convenient loading platform for the lower wash level.

Rack and Glassware Compatibility

The Lancer ULTIMA series supports a range of interchangeable washing racks and baskets.

Available configurations include general-purpose baskets, injection racks, and specialized holders for different glassware types.

The appropriate rack system is particularly important for narrow-neck flasks, volumetric glassware, and other vessels requiring internal spray coverage.

Customers should verify the exact racks, baskets, injector nozzles, and accessories included with the refurbished washer.

Lancer 815LX vs. 810LX

The Lancer ULTIMA 815LX and 810LX share a similar compact footprint, chamber capacity, and two-level washing configuration.

The principal distinction is the 815LX's integrated forced-air drying capability.

The 815LX also supports optional HEPA-filtered injector drying for compatible narrow-neck glassware.

For laboratories requiring washing and rinsing only, the 810LX may be sufficient.

For facilities seeking a more complete washing and drying workflow, the 815LX offers additional flexibility.

Refurbishment and Testing by American Instrument Exchange

American Instrument Exchange inspects, tests, and reconditions used laboratory glassware washers before shipment.

For the Lancer ULTIMA 815LX, relevant testing includes operating programmed wash cycles, evaluating water circulation and drainage, verifying heating performance, inspecting the touchscreen controller, and checking the door seal and safety interlocks.

The forced-air drying system, blower, dosing pumps, spray assemblies, water connections, and available rack accessories should also be evaluated.

Customers requiring documented temperature testing, confirmation of specific wash programs, or verification of optional HEPA-filtered injector drying should discuss these requirements with AIE before purchase.

The refurbished Lancer ULTIMA 815LX includes a 90-day warranty.

Shipping and Installation

The Lancer ULTIMA 815LX measures approximately 24 inches wide, 29.1 inches deep, and 33.5 inches high, with a manufacturer-listed weight of approximately 187 pounds.

The washer is designed for installation beneath compatible laboratory countertops and may also be installed with an appropriate optional base cabinet.

Installation requires suitable electrical service, water supply connections, and drainage.

Electrical requirements vary significantly by configuration. Manufacturer documentation identifies 120V single-phase and 208V single- or three-phase versions.

Customers should confirm the individual washer's electrical rating before installation.

The laboratory should also provide sufficient clearance for the fold-down door, loading operations, plumbing, and service access.

Related Equipment

Laboratories using the Lancer ULTIMA 815LX may also require other laboratory glassware washers, laboratory autoclaves and sterilizers, water purification systems, laboratory ovens, and laboratory glassware.

American Instrument Exchange supplies used and refurbished glassware washers and related laboratory equipment for biotechnology, pharmaceutical, academic, and industrial laboratories.

Lancer ULTIMA 815LX FAQs

What is the Lancer ULTIMA 815LX used for?

The 815LX is an automated laboratory glassware washer and dryer designed to clean, rinse, and dry compatible reusable laboratory glassware.

Does the Lancer 815LX include a drying system?

Yes. The ULTIMA 815LX includes heated forced-air chamber drying as a standard feature.

Does the 815LX have HEPA-filtered drying?

HEPA-filtered injector drying was offered as an optional feature. Its presence should be confirmed on the individual unit.

What is the chamber capacity?

The 815LX has a 140-liter chamber, equivalent to approximately 4.9 cubic feet.

How many wash programs does the 815LX support?

The ULTIMA version supports four preset programs and up to 36 user-defined programs.

What is the maximum wash temperature?

Applicable configurations reach 95°C, while the 120V version is limited to approximately 85°C.

Can the 815LX wash narrow-neck laboratory flasks?

Yes, when equipped with compatible direct-injection racks and accessories.

Does the washer support deionized-water rinsing?

Yes. The 815LX supports purified-water rinse stages when connected to an appropriate water supply.

What is the difference between the 815LX and 810LX?

The 815LX adds integrated forced-air drying and offers optional HEPA-filtered injector drying.

Are washing racks included?

The exact racks, baskets, injectors, and other accessories included with the refurbished unit should be confirmed before purchase.

Does the refurbished Lancer 815LX include a warranty?

Yes. American Instrument Exchange includes a 90-day warranty on refurbished equipment.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.