LAUDA UKT Refrigerated Recirculating Chiller
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The LAUDA UKT Refrigerated Recirculating Chiller is a laboratory and process cooling system designed to remove heat from analytical instruments, research equipment, chemical processes, and other temperature-sensitive systems. Part of LAUDA's established UKT series of circulation cooling units, these systems combine mechanical refrigeration, an integrated coolant reservoir, active fluid circulation, and temperature control in a durable platform designed for continuous laboratory and technical use.
Unlike an open cooling-water supply, the LAUDA UKT operates as a recirculating closed-loop system. Coolant is continuously pumped through compatible external equipment and returned to the chiller, providing a stable and reusable source of cooling while reducing dependence on laboratory tap water.
Available used and refurbished from American Instrument Exchange, this LAUDA UKT is inspected and tested for reliable cooling, circulation, and temperature-control performance. A 90-day warranty is included.
Refrigerated recirculating chiller
Part of the established LAUDA UKT circulation cooling series
Designed for closed-loop external cooling
Integrated refrigeration system
Active coolant circulation
Suitable for continuous laboratory and process cooling
Provides consistent cooling independent of seasonal tap-water temperature
Can reduce laboratory water consumption
Designed for analytical instruments and technical equipment
Useful for reaction and process cooling
Compact, self-contained cooling system
Durable legacy LAUDA construction
Used, refurbished, and tested by American Instrument Exchange
90-day warranty included
The LAUDA UKT series was developed as a family of dedicated circulation cooling units for applications requiring reliable removal of operating heat.
Rather than providing an open bath primarily intended for direct sample immersion, UKT systems are designed principally to circulate cooled heat-transfer fluid through compatible external equipment. The coolant absorbs heat from the connected instrument or process before returning to the chiller, where the refrigeration system removes the accumulated heat.
This closed-loop arrangement makes the UKT useful as an alternative to continuous tap-water cooling.
LAUDA produced multiple UKT configurations with different refrigeration capacities, reservoir sizes, circulation pumps, electrical requirements, and cooling arrangements. Models within the family included compact laboratory chillers as well as substantially larger process-cooling systems.
For that reason, buyers should verify the complete model designation and nameplate information of an individual UKT before selecting it for an application with specific cooling-capacity or pump-performance requirements.
| Specification | Details |
|---|---|
| Manufacturer | LAUDA |
| Series | UKT |
| Equipment Type | Refrigerated recirculating chiller |
| Cooling Method | Mechanical refrigeration |
| Circulation | Closed-loop external circulation |
| Internal Reservoir | Yes |
| Heating | Model/configuration dependent |
| Air/Water Cooling | Model/configuration dependent |
| Temperature Range | Model dependent |
| Cooling Capacity | Model dependent |
| Maximum Pump Flow | Model dependent |
| Maximum Pump Pressure | Model dependent |
| Reservoir Capacity | Model dependent |
| Electrical Requirements | Verify individual unit nameplate |
| Exact UKT Submodel | Verify individual unit nameplate |
| Warranty | 90 days |
LAUDA UKT circulation chillers can be used for a wide range of laboratory, research, analytical, and industrial cooling applications.
Typical uses include cooling rotary evaporators, condensers, analytical instruments, reaction systems, vacuum equipment, distillation apparatus, optical equipment, electron microscopes, X-ray equipment, refractometers, cooling traps, and other instruments that generate heat during operation.
A UKT chiller can also supply temperature-controlled coolant to jacketed vessels and experimental systems where process heat must be removed continuously.
Because the system recirculates coolant rather than discharging it after a single pass, it can be especially useful for laboratories looking to replace continuous tap-water cooling with a more consistent closed-loop system.
The LAUDA UKT is suitable for chemistry laboratories, pharmaceutical research facilities, biotechnology companies, analytical laboratories, materials-science groups, industrial R&D departments, process-development laboratories, academic research facilities, and other environments requiring dependable equipment cooling.
It can be particularly valuable in laboratories operating analytical or process equipment continuously, where fluctuations in building cooling-water temperature or pressure could interfere with instrument performance.
The UKT series may also be useful for laboratories maintaining legacy experimental systems originally configured around LAUDA circulation cooling equipment.
LAUDA manufactured the UKT family in several cooling-capacity classes, so temperature range and refrigeration performance depend on the exact UKT model.
This distinction is important when evaluating a used system.
The minimum attainable temperature alone does not determine whether a chiller is suitable for an application. Available cooling capacity decreases as coolant temperature falls, while the connected equipment may continuously add heat to the loop.
A properly selected chiller must therefore provide sufficient cooling capacity at the actual required operating temperature.
Ambient conditions, coolant selection, fluid flow, tubing configuration, reservoir volume, and process heat load can also influence real-world cooling performance.
Customers considering this LAUDA UKT for a specific application should provide American Instrument Exchange with the desired coolant temperature and estimated heat load so that the unit's exact configuration can be evaluated before purchase.
The LAUDA UKT series uses an integrated circulation pump to move temperature-controlled fluid through compatible external equipment.
LAUDA offered UKT models with different pump capacities, and certain versions were specifically identified by a “P” designation indicating a higher-performance pump configuration.
Pump performance should therefore be verified from the exact model rather than inferred from another UKT-series chiller.
Flow rate is particularly important for analytical instruments and processes that require a minimum coolant flow. Pressure capability may also become important when coolant must pass through restrictive tubing, narrow internal passages, elevated equipment, or complex external circuits.
For best results, tubing diameter and length should be selected to minimize unnecessary hydraulic resistance while remaining compatible with the chiller and connected equipment.
This used LAUDA UKT Refrigerated Recirculating Chiller is refurbished and tested by American Instrument Exchange before shipment. Our technicians inspect the refrigeration system, compressor, condenser, circulation pump, reservoir, temperature controller, fluid connections, electrical components, housing, and associated safety systems.
Temperature-controlled equipment is tested using NIST-traceable probes and data loggers. The UKT is operated under simulated laboratory conditions to evaluate cooling, circulation, temperature regulation, controller operation, and overall system performance.
The reservoir and accessible fluid-contact components are cleaned and inspected before shipment.
Customers requiring the chiller for a particular instrument or process are encouraged to provide the required coolant temperature, approximate heat load, minimum flow rate, and any pressure requirements. When practical, American Instrument Exchange can incorporate customer-requested operating conditions into final testing.
A 90-day warranty is included with this refurbished LAUDA recirculating chiller.
The LAUDA UKT is best suited to applications that require continuous closed-loop cooling of external laboratory or process equipment.
Compared with tap-water cooling, a dedicated recirculating chiller provides greater control over coolant temperature and eliminates variations caused by seasonal changes in incoming water temperature. It can also substantially reduce water consumption because the coolant is continuously reused rather than discharged to a drain.
Selecting the correct UKT requires more than simply choosing a desired temperature range. Buyers should consider the amount of heat generated by the connected equipment, required coolant temperature, minimum flow, pressure requirements, reservoir volume, coolant compatibility, ambient conditions, and electrical service.
This is particularly important with the UKT series because LAUDA manufactured several substantially different models under the same product-family designation.
For lower-heat-load analytical applications, a compact UKT model may be sufficient. Larger process equipment, reactors, or multiple connected instruments may require one of the higher-capacity UKT systems.
American Instrument Exchange can help compare this unit with other available LAUDA and laboratory recirculating chillers based on the requirements of the intended application.
American Instrument Exchange stocks a range of laboratory circulators, including LAUDA recirculating chillers, refrigerated/heated bath circulators, immersion coolers, and process temperature-control systems. Laboratories considering this LAUDA UKT may also want to compare available laboratory water baths, reactors and fermenters, evaporators and extractors, and other refurbished laboratory equipment.
The LAUDA UKT series consists of refrigerated circulation cooling units designed to provide closed-loop cooling for compatible laboratory, analytical, and process equipment.
The UKT series is primarily designed as a circulation cooling system for external equipment rather than as a conventional open refrigerated bath for direct sample immersion.
The exact temperature range depends on the specific UKT model and configuration. The complete model designation should be verified before selecting a unit for a particular operating temperature.
Cooling capacity varies significantly across the UKT product family. The exact model must be identified to determine available cooling capacity, particularly at temperatures below ambient.
For many compatible applications, yes. A closed-loop recirculating chiller can provide a consistent source of coolant while reducing or eliminating continuous consumption of laboratory tap water.
Potential applications include analytical instruments, rotary evaporators, condensers, reaction systems, distillation equipment, electron microscopes, X-ray equipment, optical instruments, cooling traps, and other equipment designed for external liquid cooling.
Yes. UKT systems use an integrated pump to circulate coolant through compatible external equipment. Pump flow and pressure depend on the exact model and configuration.
Historical LAUDA documentation indicates that certain UKT models were available in “P” versions equipped with a more powerful circulation pump.
Useful information includes the required coolant temperature, expected heat load, minimum coolant flow, required pressure, coolant type, electrical service, and the equipment being cooled.
Yes. This used LAUDA UKT Refrigerated Recirculating Chiller is refurbished and tested by American Instrument Exchange and includes a 90-day warranty.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.