Lauda WKL600 Recirculating Chiller
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The LAUDA WKL600 is a laboratory recirculating chiller designed to provide reliable cooling and temperature-controlled fluid circulation for laboratory instruments, research equipment, and process applications. With an operating temperature range of -25°C to +40°C, 0.65 kW of cooling capacity at 20°C, and a circulation pump capable of delivering up to 30 L/min, the WKL600 provides a practical dedicated cooling source for a variety of laboratory systems.
Available used and refurbished from American Instrument Exchange, the LAUDA WKL600 is an older-generation recirculating chiller that remains useful for laboratories requiring dependable process cooling without the cost of purchasing a new system. Its air-cooled refrigeration system eliminates the need for condenser cooling water, while its 12 L maximum filling volume and external circulation capability make it suitable for continuous laboratory cooling applications. A 90-day warranty is included.
-25°C to +40°C working temperature range
0.65 kW cooling capacity at 20°C
Maximum circulation flow of 30 L/min
Maximum pump pressure of 1.0 bar
Maximum filling volume of 12 L
Air-cooled refrigeration system
Designed for external laboratory and process cooling
Suitable as an alternative to tap-water cooling for compatible equipment
Used, refurbished, and tested by American Instrument Exchange
90-day warranty included
The LAUDA WKL600 is a refrigerated recirculating chiller designed primarily to remove heat from externally connected laboratory equipment. The system combines refrigeration, a fluid reservoir, temperature control, and a circulation pump in a self-contained unit capable of supplying a continuous stream of temperature-controlled coolant.
Unlike a conventional laboratory water bath, where samples are typically placed directly into a temperature-controlled reservoir, the WKL600 is intended primarily to circulate coolant through external equipment. This makes it useful for instruments and processes that continuously generate heat and require a reliable cooling source.
The WKL600 can also provide an alternative to once-through tap-water cooling. In suitable applications, recirculating coolant reduces dependence on facility water while providing greater control over coolant temperature and circulation conditions.
Although the WKL600 is an older LAUDA platform, its straightforward design and useful cooling and pump specifications can still make it a practical choice for laboratories seeking a cost-effective refurbished recirculating chiller.
| Specification | Details |
|---|---|
| Manufacturer | LAUDA |
| Model | WKL600 |
| Equipment Type | Recirculating chiller |
| Working Temperature Range | -25°C to +40°C |
| Ambient Temperature Range | +5°C to +40°C |
| Temperature Control | ±1.0°C |
| Cooling Capacity at 20°C | 0.65 kW |
| Maximum Pump Flow | 30 L/min |
| Maximum Pump Pressure | 1.0 bar |
| Maximum Filling Volume | 12 L |
| Condenser | Air-cooled |
| Exterior Dimensions | 350 × 480 × 595 mm |
| Exterior Dimensions, Approx. | 13.8 in. W × 18.9 in. D × 23.4 in. H |
| Application | External cooling and fluid circulation |
| Warranty | 90 days |
The LAUDA WKL600 can support a wide variety of laboratory equipment requiring continuous cooling or controlled coolant circulation. Typical applications include rotary evaporators, analytical instruments, refractometers, distillation systems, cooling traps, electron microscopes, X-ray equipment, and other instruments that generate heat during operation.
The WKL600 can also be used as part of a centralized cooling-water system for compatible laboratory equipment. Recirculating a controlled volume of coolant can provide an alternative to continuously sending facility water through laboratory instruments and then to drain.
Because cooling requirements vary substantially between instruments, users should compare the WKL600's available cooling capacity, temperature range, pump flow, and pressure with the requirements of the equipment being connected.
The LAUDA WKL600 is suitable for chemistry laboratories, pharmaceutical and biotechnology facilities, analytical laboratories, materials-science groups, industrial research facilities, quality-control laboratories, academic research departments, and other environments requiring dedicated equipment cooling.
Its relatively straightforward recirculating-chiller configuration can be particularly useful for laboratories replacing an older cooling system or seeking a cost-effective dedicated coolant source for existing analytical or process equipment.
The WKL600 provides a working temperature range from -25°C to +40°C with specified temperature control of approximately ±1.0°C. This range allows the chiller to provide both below-ambient refrigeration and controlled cooling near ambient temperatures.
Cooling capacity is approximately 0.65 kW at a circulating-fluid temperature of 20°C. As with other refrigerated circulators and chillers, available cooling capacity changes with operating temperature. Buyers should therefore evaluate the thermal load generated by the connected equipment at the intended coolant temperature rather than selecting a chiller based only on its minimum temperature specification.
For applications requiring substantially tighter temperature stability or highly dynamic temperature control, a newer-generation laboratory circulator may be more appropriate. For general equipment cooling and heat-removal applications, however, the WKL600 offers useful performance across a broad range of laboratory conditions.
The LAUDA WKL600 provides a maximum circulation flow rate of 30 L/min and maximum pump pressure of 1.0 bar. These specifications allow the chiller to circulate coolant through a range of compatible external laboratory instruments and process systems.
Actual flow at the connected equipment will depend on the complete fluid circuit. Tubing diameter and length, fittings, elevation, coolant viscosity, operating temperature, and internal restrictions within the connected instrument can all reduce flow from the pump's maximum rating.
Before connecting the WKL600, laboratories should verify the allowable pressure and required flow of the equipment being cooled. Proper tubing selection and installation can help maximize heat-transfer performance while avoiding unnecessary restrictions in the circulation loop.
This used LAUDA WKL600 is refurbished and tested by American Instrument Exchange before shipment. Our technicians inspect the refrigeration, circulation, temperature-control, electrical, and user-interface systems and operate the unit to confirm proper functionality.
Temperature-controlled equipment is tested using NIST-traceable probes and data loggers. The pump is evaluated for proper operation and circulation, while the refrigeration system is operated to confirm that the chiller reaches and maintains appropriate temperatures. The reservoir and fluid-contact areas are cleaned and the system is prepared for shipment following testing.
If your application requires operation at a particular coolant temperature or under specific conditions, contact American Instrument Exchange before shipment. When practical, our technicians can incorporate customer-requested operating conditions into final testing.
A 90-day warranty is included with this refurbished LAUDA recirculating chiller.
When selecting a laboratory recirculating chiller, four specifications are particularly important: target coolant temperature, required cooling capacity, circulation flow, and pump pressure. The connected equipment's heat output should be compared with the chiller's available cooling capacity at the intended operating temperature.
The WKL600 is particularly appropriate for moderate cooling loads that fall within its -25°C to +40°C operating range and 0.65 kW cooling capacity at 20°C. Its 30 L/min maximum flow rate also provides substantial fluid circulation for compatible external equipment.
Laboratories requiring much higher heat-removal capacity, extremely tight temperature stability, very low operating temperatures, or sophisticated programmable control may benefit from a newer or higher-capacity circulator. For many straightforward instrument-cooling applications, however, a refurbished WKL600 can provide a cost-effective alternative to purchasing a new recirculating chiller.
American Instrument Exchange can help compare available used and refurbished laboratory circulators based on your required temperature, heat load, pump requirements, and application.
American Instrument Exchange stocks a range of laboratory circulators, including refrigerated circulators, heating circulators, recirculating chillers, and other temperature-control systems. Laboratories using the WKL600 may also require laboratory water baths, evaporators and extractors, reactors and fermenters, or other refurbished laboratory equipment.
The LAUDA WKL600 has a working temperature range of -25°C to +40°C, allowing it to provide refrigerated cooling for a variety of laboratory instruments and processes.
The WKL600 provides approximately 0.65 kW of cooling capacity at a circulating-fluid temperature of 20°C. Available cooling capacity varies with operating temperature and conditions.
The circulation pump provides a maximum flow rate of approximately 30 L/min with a maximum pump pressure of 1.0 bar. Actual flow through connected equipment depends on the hydraulic resistance of the complete circulation loop.
For compatible applications, yes. A recirculating chiller can provide a closed-loop source of temperature-controlled coolant rather than continuously using facility water and sending it to drain. The chiller's cooling capacity and pump performance should first be compared with the requirements of the equipment being cooled.
Yes, provided the cooling requirements of the particular rotary evaporator and condenser are within the WKL600's operating capabilities. Recirculating chillers are commonly used to supply coolant to rotary evaporator condensers.
Yes. For applications that fall within its temperature, cooling-capacity, and circulation specifications, a properly refurbished WKL600 can still provide a practical dedicated cooling solution. Buyers requiring advanced programming, tighter temperature control, or greater cooling capacity may prefer a newer-generation circulator.
Yes. This used LAUDA WKL600 is refurbished and tested by American Instrument Exchange and includes a 90-day warranty.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.