Mettler Toledo ME303E Precision Balance
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Mettler Toledo ME303E Precision Balance is a refurbished precision laboratory balance offering 320 g weighing capacity and 0.001 g readability. It is designed for routine reagent preparation, media components, and general laboratory quality control. American Instrument Exchange provides inspected, tested laboratory weighing equipment backed by a 90-day warranty.
The backlit LCD, integrated RS232 connection, robust metal base and ten application modes make the ME303E suitable for everyday weighing. For laboratories evaluating a used balance, the key purchasing considerations are not only capacity and readability, but also the condition of the weighing mechanism, installed accessories, adjustment system and performance after shipment.
The Mettler Toledo ME303E Precision Balance addresses the need for dependable mass determination in routine reagent preparation, media components, and general laboratory quality control. Its 0.001 g display increment helps operators resolve small changes in load, while the 320 g weighing range determines the size of samples and containers it can accommodate. Selecting the correct combination is essential: an instrument with high resolution but insufficient capacity may not support the intended vessels, while a larger-capacity model with coarse readability may not suit sensitive procedures.
Manufacturer specifications explicitly identify external adjustment; the previous AIE listing incorrectly claimed internal calibration. The ME303E is a 1 mg precision balance rather than a 0.1 mg analytical balance. These characteristics distinguish the model from generic digital scales and should be considered alongside adjustment requirements, installation conditions and available interfaces. A refurbished balance can provide a cost-effective solution for laboratories replacing aging equipment, expanding capacity or equipping additional workstations.
Typical uses include routine reagent preparation, media components, and general laboratory quality control, preparation of working solutions, weighing laboratory consumables, and documenting masses for repeatable experimental procedures. Weighing powders, ingredients, containers and formulation components often requires a balance that can accommodate both the sample and its vessel without sacrificing useful resolution.
The Mettler Toledo ME303E Precision Balance can also support training, method development and quality-control checks when the selected test masses are appropriate for its operating range. Before adopting a new method, confirm that the instrument's actual repeatability and measurement uncertainty meet the procedure's acceptance criteria.
Research institutions, pharmaceutical and biotechnology facilities, chemical laboratories, environmental testing groups, universities and industrial quality-control departments may find this model useful. Its suitability depends on the actual sample sizes, laboratory throughput and degree of documentation required.
For shared laboratories, written operating instructions help standardize taring, adjustment and cleaning practices between users. Regulated facilities should incorporate the balance into their existing equipment qualification, calibration and record-retention procedures rather than assuming that a manufacturer's feature list alone establishes compliance.
The published capacity is 320 g, with 0.001 g readability. Available technical information identifies repeatability as 0.7 mg typical and linearity as Verify unit; where a value is marked for verification, it should not be treated as a guaranteed specification for the particular refurbished instrument. Repeatability describes variation across repeated weighings of the same load, while linearity evaluates agreement across the instrument's range.
A displayed increment does not equal guaranteed accuracy. Select an appropriate operating range and determine acceptable weighing uncertainty through reference-weight verification and repeatability studies. For small portions, the balance may need finer resolution than a routine formulation task. The most useful performance test for a prospective application is one that uses representative masses, suitable reference weights and the same environmental conditions expected during normal operation.
The backlit LCD, integrated RS232 connection, robust metal base and ten application modes make the ME303E suitable for everyday weighing. Manufacturer specifications explicitly identify external adjustment; the previous AIE listing incorrectly claimed internal calibration. The ME303E is a 1 mg precision balance rather than a 0.1 mg analytical balance.
Typical settling time is 1.5 seconds; manufacturer-listed USP minimum weight is 1.4 g, subject to site-specific testing. Confirm model suffixes and the installed hardware before relying on optional accessories or special weighing modes. A similar-looking balance from the same manufacturer may have a different adjustment system, range or communications package.
The listed adjustment approach is External adjustment. Adjustment brings the balance's response into agreement with its reference, whereas calibration or performance verification documents how the instrument behaves against known test masses. The two procedures are related but should not be treated as interchangeable.
Use suitable reference weights, allow adequate warm-up and follow the applicable manufacturer procedure. For laboratories using the instrument in regulated or high-precision applications, document the weight identification, test points, environmental conditions and acceptance limits. After relocation or shipping, repeat relevant checks before reporting critical measurements.
Choose a level, vibration-resistant bench away from fans, frequently opened doors and temperature swings. Even robust top-loading balances perform better when protected from unnecessary air movement and bench vibration. For routine precision weighing, place the vessel near the center of the pan, tare consistently, and avoid overloading the instrument. Heavy vessels should be lowered gently to protect the weighing cell and prevent shock loading.
An appropriate work surface, stable temperature and controlled handling technique are often as important as nominal resolution. If a reading drifts or fails to settle, investigate airflow, vibration, electrostatic effects, warm samples and incorrect leveling before concluding that the weighing mechanism requires adjustment.
Routine use begins with confirming a stable zero indication, selecting the required unit, placing a clean vessel on the pan and applying tare before adding the sample. Record results only after the stability indication or equivalent measurement criterion is satisfied. Where the instrument supports counting, percent weighing, formulation or data transfer, configure those functions to match the laboratory's procedure.
For electronic records, verify the interfaces physically installed on this refurbished unit and the compatibility of any printer or computer connection. Manual transcription may be adequate for low-throughput work, but documented data transfer can reduce recording errors when a compatible interface is available. Optional hardware should not be assumed to be included.
| Specification | Details |
|---|---|
| Manufacturer / model | Mettler Toledo ME303E Precision Balance |
| Equipment type | precision balance |
| Maximum capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | 0.7 mg typical |
| Linearity | Verify unit |
| Adjustment | External adjustment |
| Weighing pan | 120 mm diameter |
| Minimum sample weight | Determine under actual laboratory conditions |
| Power supply | Confirm label and included adapter |
| Exterior dimensions / weight | Confirm installed configuration |
| Condition | Used and refurbished |
| Warranty | 90 days from American Instrument Exchange |
Specifications are based on available manufacturer or model references and existing AIE product information. Optional equipment and performance of an individual used unit should be confirmed before ordering.
American Instrument Exchange inspects and cleans used laboratory balances and evaluates relevant weighing functions before shipment. Checks may include display and keypad operation, zero and tare response, repeatability with repeated reference loads, linearity at multiple points, and corner-load behavior. Installed adjustment systems, draft shields and communications features are checked as applicable.
The purpose of refurbishment is to provide an operational instrument with documented functional checks, not to imply that every used unit is identical to a new factory instrument. Customers with specialized qualification or acceptance requirements should communicate those needs before purchase. A 90-day warranty is included from American Instrument Exchange.
Protect the weighing platform and mechanism from shock in transit. On arrival, inspect the pan and level feet, allow the instrument to reach room conditions, and complete a reference-weight check before putting it into routine use. Place the balance on a stable surface, install the pan and included accessories, check leveling and perform adjustment or external verification as appropriate.
Before ordering, confirm the supplied power adapter, pan, draft shield, interface accessories and any calibration weights needed for the laboratory's procedures. Shipping arrangements should account for the sensitivity of the weighing mechanism and the possibility of fragile enclosure components.
Explore additional laboratory balances from American Instrument Exchange, including analytical, semi-micro and precision models. Laboratories expanding sample-preparation capabilities can also source centrifuges, water baths, incubators, laboratory refrigerators and laboratory freezers.
The stated maximum capacity or operating range is 320 g. Include the tare vessel when calculating the load.
The model displays mass in 0.001 g increments within its applicable weighing range.
It is designed for those types of applications, provided its actual repeatability, capacity and uncertainty meet the laboratory's method requirements.
The documented adjustment approach is External adjustment. Confirm the actual installed configuration and perform external verification according to laboratory procedures.
Measure repeatability under the laboratory's conditions and apply the relevant uncertainty or method criteria. Display readability alone is not sufficient.
American Instrument Exchange evaluates applicable weighing and operating functions, including repeatability, linearity, corner-load response, controls and installed adjustment features.
Yes. A 90-day warranty is included from American Instrument Exchange.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.