Mettler MS205DU semi micro balance

Fully Tested & Warrantied*
Brand : Mettler Toledo
Product Code : SKU 0664S BALANCE
Title: $4550.00

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Mettler Toledo MS205DU Dual-Range Semi-Micro Balance – Used & Refurbished

The Mettler Toledo MS205DU Dual-Range Semi-Micro Balance combines 10 µg readability through an 82 g fine range with 0.1 mg readability through its full 220 g weighing range, giving laboratories two useful levels of precision in a single instrument. This dual-range design allows the MS205DU to handle demanding semi-micro measurements while retaining substantially more capacity for routine analytical weighing, tare containers, and larger samples.

Available used and refurbished from American Instrument Exchange, the Mettler Toledo MS205DU incorporates MonoBloc weighing technology, FACT automatic internal adjustment, an enclosed draft shield with ergonomic ErgoDoors, QuickLock removable glass panels, an 80 mm weighing pan, and a robust metal housing. It is particularly well suited for pharmaceutical, biotechnology, chemical, environmental, academic, research, and quality-control laboratories that need microgram-level resolution without sacrificing the flexibility of a 220 g analytical weighing range.

Each balance is inspected, cleaned, calibrated, and tested for weighing performance before shipment and includes a 90-day warranty from American Instrument Exchange.

Key Features

  • Dual-range semi-micro weighing

  • 82 g fine-range capacity with 0.01 mg / 10 µg readability

  • 220 g full-range capacity with 0.1 mg readability

  • Typical repeatability of approximately 0.015 mg at low load

  • Repeatability limit of 0.08 mg at nominal load

  • Fine-range repeatability limit of 0.05 mg at nominal fine-range load

  • Linearity deviation limit of 0.2 mg

  • Typical USP minimum sample weight of approximately 30 mg

  • Typical minimum weight of approximately 3 mg at U=1%, k=2

  • FACT automatic internal adjustment

  • Two internal reference weights

  • MonoBloc weighing technology

  • 80 mm diameter weighing pan

  • Fully enclosed draft shield

  • Ergonomic ErgoDoors

  • QuickLock removable draft-shield glass panels

  • High-contrast display

  • Robust die-cast aluminum housing

  • Compact, space-efficient design

  • Used, refurbished, calibrated, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Mettler Toledo MS205DU is designed for laboratories that need greater sensitivity than a conventional analytical balance while still requiring enough capacity for everyday analytical weighing.

Its dual-range weighing system is the key advantage.

Within the 82 g fine range, the MS205DU provides 0.01 mg, or 10 µg, readability. This allows the balance to resolve extremely small mass differences and supports demanding quantitative applications involving small samples.

Across the balance's full 220 g capacity, readability changes to 0.1 mg, providing the performance expected from a high-quality analytical balance.

This means a laboratory does not necessarily need separate semi-micro and analytical balances for these two types of work.

The MS205DU can perform highly sensitive measurements when required while still accommodating larger samples, weighing vessels, and routine analytical procedures.

For laboratories with varied sample sizes and measurement requirements, this flexibility can make the MS205DU a particularly valuable analytical instrument.

Common Applications

The Mettler Toledo MS205DU is well suited for standards preparation, pharmaceutical formulation, quantitative chemical analysis, gravimetric analysis, sample preparation, reagent weighing, filter weighing, loss-on-drying studies, quality control, research, and other high-accuracy analytical procedures.

Pharmaceutical and biotechnology laboratories can use the MS205DU for reference-standard preparation, active ingredient research, formulation development, analytical sample preparation, and quality-control procedures.

Chemical and environmental laboratories can use its fine range for small samples, residues, filters, compounds, and quantitative analytical work while retaining the ability to weigh larger quantities in the full analytical range.

Academic and research laboratories may find the dual-range architecture particularly useful because a single balance can support both routine analytical weighing and more demanding semi-micro research.

Ideal Laboratory Types

The MS205DU is a strong choice for pharmaceutical, biotechnology, chemical, environmental, academic, forensic, research, quality-control, and analytical testing laboratories.

It is particularly useful when a laboratory sometimes requires 10 µg readability but does not perform enough microgram-level weighing to justify dedicating a separate semi-microbalance to every workstation.

The MS205DU can function as a high-performance analytical balance for routine work and transition into its fine range when smaller samples or greater measurement resolution are required.

This versatility can be especially valuable in multi-user laboratories where sample sizes and analytical requirements change throughout the day.

Dual-Range Semi-Micro Weighing Performance

The defining characteristic of the MS205DU is its dual-range weighing system.

The balance provides:

0.01 mg / 10 µg readability from 0 to 82 g, and

0.1 mg readability through its full 220 g capacity.

This provides two distinct levels of measurement resolution without requiring the operator to switch instruments.

The fine range is ideal for demanding analytical work involving relatively small quantities.

The full range allows larger samples and containers to be weighed while maintaining analytical-balance resolution.

Mettler Toledo specifies a repeatability limit of 0.08 mg at nominal load, while typical repeatability at low load is approximately 0.015 mg under appropriate conditions.

Within the fine range, the specified repeatability limit at nominal fine-range load is approximately 0.05 mg.

Linearity deviation is specified at 0.2 mg.

Understanding the 82 g Fine Range

The 82 g fine range deserves particular attention when selecting the MS205DU.

The balance does not provide 0.01 mg readability throughout its entire 220 g capacity.

Instead, its highest resolution is available within the fine weighing range.

This distinction matters when planning applications.

If the combined weight of the sample and tare container remains within the fine range, the balance can provide 10 µg displayed resolution.

If the working load requires the full weighing range, the MS205DU continues to operate as a high-quality analytical balance with 0.1 mg readability.

Laboratories purchasing a dual-range balance should therefore consider not only the weight of the sample but also the weight of weighing vessels, containers, filters, pans, and other items placed on the balance.

Minimum Sample Weight & USP Applications

Mettler Toledo specifies a typical USP minimum sample weight of approximately 30 mg for the MS205DU under stated reference conditions.

The manufacturer also specifies a typical minimum weight of approximately 3 mg at U=1%, k=2.

These values illustrate one of the principal advantages of semi-micro weighing.

A laboratory working with very small quantities may be unable to achieve the required measurement uncertainty using a conventional analytical or precision balance, even if the instrument displays the desired number of decimal places.

Minimum weight is determined by balance repeatability and the uncertainty requirements of the procedure—not simply by readability.

Actual minimum weight should therefore be established for the individual installed balance under its real operating conditions.

For USP, GMP, GLP, or other regulated procedures, laboratories should determine and document minimum sample weight according to their applicable quality system and weighing requirements.

Controlling Drafts, Vibration & Static

At 10 µg readability, environmental control becomes an important part of obtaining reliable weighing results.

Air movement, vibration, electrostatic charge, temperature gradients, operator technique, and even sample temperature can influence semi-micro measurements.

The MS205DU incorporates an enclosed draft shield to isolate the weighing pan from routine laboratory air movement.

The balance should also be installed on a rigid, stable weighing surface, preferably away from centrifuges, shakers, pumps, compressors, doors, HVAC outlets, and high-traffic areas.

Static electricity can become particularly important when weighing powders, filters, plastic containers, or other low-mass materials.

Where static is a concern, laboratories may need to use appropriate antistatic techniques or equipment.

Samples and containers should also be allowed to equilibrate to the weighing environment whenever practical before critical semi-micro measurements are performed.

FACT Automatic Internal Adjustment

The MS205DU incorporates FACT automatic internal adjustment using two internal reference weights.

FACT helps maintain weighing performance by allowing the balance to automatically test and adjust itself as operating conditions change.

This is especially important for semi-micro weighing because very small environmental changes can become significant at 10 µg resolution.

Internal adjustment also eliminates the need for operators to manually place external calibration weights on the balance every time routine adjustment is required.

FACT should not be confused with external performance verification.

Laboratories operating under USP, GMP, GLP, ISO, or internal quality procedures may still require periodic testing using appropriate traceable external reference weights.

American Instrument Exchange calibrates and evaluates each refurbished MS205DU before shipment and verifies operation of the FACT adjustment system.

ErgoDoors & Draft Shield Design

The MS205DU incorporates Mettler Toledo's ErgoDoor draft-shield system, designed to make repetitive sample handling more convenient.

The doors are arranged so an operator can open the opposite-side door while simultaneously placing or removing a sample with the other hand.

This reduces unnecessary hand movement during repetitive weighing.

The draft-shield doors also remain within the footprint of the balance when opened rather than projecting substantially outward.

This makes the MS205DU well suited for crowded analytical benches where workspace is limited.

The enclosed chamber provides the environmental protection required for high-resolution weighing while retaining convenient access to the weighing pan.

QuickLock Cleaning & Contamination Control

Keeping a semi-microbalance clean is particularly important when working with powders, active pharmaceutical ingredients, chemicals, standards, and other materials that can accumulate inside the weighing chamber.

The MS205DU incorporates QuickLock removable draft-shield panels.

The glass panels can be removed without tools, simplifying routine cleaning of both the glass and the weighing chamber.

This design can be particularly valuable in pharmaceutical, biotechnology, chemical, and multi-user laboratories where the balance may be exposed to different sample types throughout the day.

Easy cleaning helps reduce cross-contamination and prevents accumulated material from interfering with sensitive weighing procedures.

Key Specifications

Specification Mettler Toledo MS205DU
Balance Type Dual-Range Semi-Micro / Analytical Balance
Maximum Capacity 220 g
Fine-Range Capacity 82 g
Full-Range Readability 0.1 mg
Fine-Range Readability 0.01 mg / 10 µg
Repeatability Limit at Nominal Load 0.08 mg
Fine-Range Repeatability Limit 0.05 mg
Typical Repeatability at Low Load Approx. 0.015 mg
Linearity Deviation Limit ±0.2 mg
Typical Linearity Deviation Approx. 0.06 mg
Typical USP Minimum Weight Approx. 30 mg
Typical Minimum Weight (U=1%, k=2) Approx. 3 mg
Adjustment Internal / automatic FACT
Internal Reference Weights 2
Weighing Technology MonoBloc
Weighing Pan 80 mm diameter
Draft Shield Enclosed with ErgoDoors
Usable Draft-Shield Height Approx. 235 mm
Overall Dimensions 247 mm W × 358 mm D × 331 mm H
Balance Weight Approx. 6.8 kg
Display High-contrast display
Housing Die-cast aluminum / polymer components
Standard Model Legal for Trade No

Choosing Between a Semi-Micro and Analytical Balance

A conventional analytical balance generally provides 0.1 mg readability.

That level of resolution is appropriate for a broad range of laboratory procedures, including routine quantitative analysis, reagent preparation, standards preparation, and general analytical work.

A semi-microbalance such as the MS205DU increases resolution to 0.01 mg / 10 µg within its fine range.

That tenfold improvement becomes valuable when working with smaller samples, expensive compounds, reference materials, filters, residues, or procedures where reducing minimum sample weight is important.

The tradeoff is increased environmental sensitivity.

Semi-micro measurements require greater attention to airflow, vibration, static electricity, temperature stability, and operator technique.

The MS205DU provides an attractive compromise because it offers both semi-micro and analytical weighing ranges in the same instrument.

MS205DU vs. a Single-Range Semi-Microbalance

The MS205DU is a dual-range balance.

It provides 10 µg readability through 82 g and then transitions to 0.1 mg readability through its full 220 g capacity.

A single-range semi-microbalance may provide its highest readability throughout its entire weighing range.

The advantage of the MS205DU is flexibility.

Laboratories can perform high-resolution semi-micro work when necessary while retaining a substantially larger analytical weighing range for routine samples and heavier containers.

A single-range model may be preferable when virtually every measurement requires maximum resolution.

The MS205DU is particularly attractive when laboratory workloads regularly alternate between semi-micro and conventional analytical weighing.

MS205DU vs. MS105DU

Both the Mettler Toledo MS205DU and MS105DU are dual-range semi-microbalances providing 0.01 mg readability in their fine ranges and 0.1 mg readability in their full ranges.

The principal difference is capacity.

The MS105DU provides approximately 42 g of fine-range capacity and 120 g maximum capacity.

The MS205DU increases those limits to 82 g fine-range capacity and 220 g maximum capacity.

The MS205DU is therefore better suited for laboratories working with heavier tare containers, larger samples, or procedures where greater working capacity is valuable.

The MS105DU may provide sufficient capacity for laboratories whose semi-micro work primarily involves smaller samples and vessels.

Refurbishment & Performance Testing

Every used Mettler Toledo MS205DU sold by American Instrument Exchange is inspected, cleaned, refurbished as necessary, calibrated, and tested before shipment.

Our technicians use appropriate traceable calibration weights to evaluate critical weighing characteristics including accuracy, repeatability, linearity, corner-load performance, stability, and reduced span across appropriate portions of the weighing range.

For a dual-range semi-microbalance, testing must account for both the 10 µg fine range and the 0.1 mg full analytical range.

The MonoBloc weighing system, FACT automatic internal adjustment, display, controls, ErgoDoors, draft shield, leveling components, weighing pan, and installed interfaces are inspected and tested for proper operation.

The weighing chamber and removable glass panels are thoroughly cleaned, and the balance receives a final operational inspection before shipment.

Each refurbished MS205DU includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation Considerations

Semi-microbalances require careful handling during transportation and installation.

American Instrument Exchange securely prepares the MS205DU for shipment to protect its MonoBloc weighing system, weighing pan, draf

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.