The Mettler Toledo XPE205 analytical balance is available used and refurbished from American Instrument Exchange, offering 220 g capacity and 0.01 mg readability for reference standards, pharmaceutical formulation, and analytical chemistry. The balance is inspected and tested before shipment and includes a 90-day warranty.
The Mettler Toledo XPE205 analytical balance is a semi-micro analytical laboratory balance designed for reference standards, pharmaceutical formulation, and analytical chemistry. With 220 g capacity and 0.01 mg readability, it combines the advanced workflow features of Mettler Toledo's Excellence Plus platform with a weighing range suited to its intended application.
SmartGrid, StatusLight, LevelGuide, StaticDetect, proFACT and touchscreen controls. This particular unit includes an RS-P42 printer, a useful accessory for paper-based weighing records. Confirm cables and printer operation before ordering. Refurbished balances can offer laboratories a practical way to expand weighing capacity while controlling equipment budgets.
Applications include reference standards, pharmaceutical formulation, and analytical chemistry, gravimetric sample preparation, quantitative laboratory procedures, and routine quality-control measurements. Laboratory users should consider both the net sample mass and the tare vessel when selecting an appropriate capacity.
In pharmaceutical and chemical workflows, consistent taring, careful transfer of powders or liquids, and documented results help reduce variability between operators. Weighing performance should be checked against the uncertainty requirements of the specific method.
The XPE205 may be appropriate for pharmaceutical, biotechnology, chemical, academic, environmental and industrial quality-control laboratories. Its suitability for regulated applications depends on qualification of the individual instrument, calibration records and the laboratory's standard operating procedures.
The stated capacity is 220 g and the displayed increment is 0.01 mg. Readability is not equivalent to accuracy or a validated minimum sample weight. The installed balance should be checked for repeatability, linearity, sensitivity and eccentric loading using suitable reference weights.
This particular unit includes an RS-P42 printer, a useful accessory for paper-based weighing records. Confirm cables and printer operation before ordering. Typical manufacturer performance figures are not substitutes for testing the actual refurbished unit after installation.
For procedures requiring a minimum sample weight, establish the threshold from measured repeatability under actual operating conditions and the applicable uncertainty limits. The smallest display increment alone cannot establish whether a particular sample mass can be weighed with sufficient confidence.
Methods involving small quantities may be affected by electrostatic charge, moisture exchange, container temperature and sample-transfer losses. These effects should be evaluated alongside the balance's mechanical performance.
The Excellence Plus platform includes advanced adjustment and monitoring functions, but the installed configuration and operation should be confirmed for this unit. Adjustment changes the instrument's response; calibration or verification documents performance against known masses. Laboratories should use appropriate traceable reference weights and retain records of test points and acceptance criteria.
Install the balance on a rigid, level surface away from air vents, doors, direct sunlight and vibration-producing equipment. Allow the balance and samples to acclimate before critical measurements. For high-resolution models, keep the draft shield closed and take precautions against static electricity. For larger-capacity models, ensure the bench supports the full gross load and that containers are centered on the weighing pan.
Always wait for a stable indication before recording results. Clean the weighing area regularly and follow manufacturer instructions when removing pans or draft-shield components.
SmartGrid, StatusLight, LevelGuide, StaticDetect, proFACT and touchscreen controls. The user interface can support routine weighing and application-oriented workflows. Verify the installed software functions and communication interfaces before relying on specific features in a laboratory information system.
For documentation, establish a consistent procedure for operator identification, measurement records and adjustment checks. Optional printers, cables and software licenses should be confirmed as part of the included configuration.
| Specification | Details |
|---|---|
| Manufacturer | Mettler Toledo |
| Model | XPE205 |
| Balance type | semi-micro analytical |
| Capacity | 220 g |
| Readability | 0.01 mg |
| Interface / controls | Excellence Plus touchscreen platform |
| Adjustment | proFACT / verify installed configuration |
| Repeatability / linearity | Verify model literature and unit test results |
| Weighing pan dimensions | Confirm installed configuration |
| Exterior dimensions / weight | Confirm installed configuration |
| Included printer | RS-P42 printer listed |
| Power requirements | Confirm instrument label and adapter |
| Condition | Used and refurbished |
| Warranty | 90 days from American Instrument Exchange |
American Instrument Exchange inspects and cleans used laboratory balances and checks applicable weighing functions before shipment. Testing may include zero and tare response, accuracy at multiple loads, repeatability, linearity, corner-load response, and operation of installed displays, controls and adjustment features.
Testing the actual instrument matters because individual refurbished units can differ in condition and installed accessories. Customers with special calibration, qualification or reporting requirements should communicate them before ordering. A 90-day warranty is included from American Instrument Exchange.
Precision weighing mechanisms should be protected against shock during shipping. On arrival, inspect the instrument, install the supplied pan and accessories, level the balance, and allow it to reach room temperature before adjustment and verification.
For critical measurements, perform acceptance testing at the point of use. Confirm the power adapter, cables, draft shield, printer and other accessories included with the specific unit before purchase.
Compare additional laboratory balances, centrifuges, incubators, and laboratory refrigerators from American Instrument Exchange. Laboratories evaluating the XPE205 can also review other XPE models with different weighing capacities and resolutions to select a configuration that matches their sample sizes and methods.
220 g.
0.01 mg. This is the displayed increment, not a guaranteed minimum sample weight.
The XPE platform supports advanced adjustment features; verify operation and configuration of the specific instrument.
The listing identifies an RS-P42 printer. Confirm cables and operating condition.
Applicable weighing and functional checks include repeatability, linearity, zero, tare and corner-load response.
A 90-day warranty from American Instrument Exchange.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.