The Nuaire LabGard NU-430-400 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment performance. Commonly used for pharmaceutical research, hazardous drug handling, microbiology workflows, biotechnology applications, and laboratory procedures involving volatile toxic chemicals or radionuclides, this refurbished Nuaire biosafety cabinet offers advanced containment performance for laboratories requiring a Class II Type B2 configuration.
At American Instrument Exchange, each biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories outfitting high-containment workflows may also browse additional refurbished biosafety cabinets, autoclaves, laboratory freezers, centrifuges, and CO2 incubators available through American Instrument Exchange.
The Nuaire LabGard NU-430-400 is a 4-foot Class II Type B2 biosafety cabinet engineered for laboratory environments requiring contamination control, sterile airflow, operator protection, and total exhaust containment capability. Unlike recirculating Type A2 biosafety cabinets, the NU-430 series is designed for hard-ducted operation and exhausts 100% of cabinet airflow through a dedicated facility exhaust system without recirculation inside the cabinet workspace.
This configuration may make the NU-430-400 appropriate for laboratory procedures involving volatile toxic chemicals, hazardous drug preparation, radionuclides, pharmaceutical compounding, microbiology workflows, and contamination-sensitive research applications requiring maximum exhaust containment performance.
The NU-430 series is commonly used throughout biotechnology laboratories, pharmaceutical facilities, hospital research environments, cleanrooms, academic research institutions, and government laboratories because of its total exhaust airflow configuration and high-containment capability.
Features may include HEPEX™ airflow construction, stainless steel work surfaces, airflow monitoring systems, ergonomic sash positioning, fluorescent lighting, removable work trays, and heavy-duty cabinet construction depending on the specific configuration of the unit.
The compact 4-foot footprint may make this biosafety cabinet especially appropriate for laboratories requiring total exhaust containment capability while conserving valuable laboratory floor space.
Laboratories outfitting complete containment workflows may also be interested in refurbished ultra-low temperature freezers, laboratory refrigerators, incubators, and laboratory water baths from American Instrument Exchange.
The Nuaire LabGard NU-430-400 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, contamination control, and total exhaust operation. Typical applications include hazardous drug handling, pharmaceutical preparation, microbiology workflows, tissue culture procedures, biotechnology research, biological sample handling, and laboratory procedures involving volatile toxic chemicals or radionuclides.
This biosafety cabinet may also be appropriate for pharmaceutical production facilities, hospital pharmacies, biotechnology laboratories, clinical testing laboratories, academic research facilities, government research institutions, and cleanroom environments requiring a ducted Class II Type B2 biosafety cabinet.
This biosafety cabinet may be suitable for pharmaceutical production facilities, biotechnology laboratories, hospital research environments, academic research facilities, cleanrooms, government laboratories, and containment-focused laboratory applications requiring a ducted Class II Type B2 biosafety cabinet.
Its total exhaust airflow configuration may make it especially appropriate for laboratories requiring additional chemical containment capability beyond standard recirculating biosafety cabinet systems.
|
Specification |
Details |
|
Manufacturer |
Nuaire |
|
Model |
LabGard NU-430-400 |
|
Cabinet Class |
Class II Type B2 |
|
Nominal Width |
4 ft |
|
Airflow Design |
100% total exhaust |
|
Exhaust Requirement |
Hard-ducted facility exhaust connection |
|
Exterior Dimensions |
Approx. 53–54” W × 32–33” D × 61–63” H |
|
Interior Work Area Dimensions |
Approx. 46” W × 23.5” D × 28.5” H |
|
Sash Opening |
10 in |
|
Filtration |
HEPA supply and exhaust filtration |
|
Electrical Requirements |
115V, 60 Hz |
|
Included Accessories |
Stand and new HEPA filters |
|
Warranty |
90-day warranty |
|
Condition |
Refurbished |
American Instrument Exchange has extensive experience refurbishing used biosafety cabinets and laboratory containment equipment for research and pharmaceutical environments.
Each biosafety cabinet is inspected by our technicians to verify proper blower operation, airflow performance, sash operation, control operation, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.
Testing procedures include major functional and airflow verification elements associated with biosafety cabinet performance to help support certification readiness upon installation at your facility. Because this is a ducted Class II Type B2 biosafety cabinet, final certification should be completed after exhaust connection and installation by qualified field technicians in accordance with laboratory requirements.
Class II Type B2 biosafety cabinets should be certified by qualified field technicians after installation and exhaust connection before laboratory use.
American Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, exhaust requirements, airflow requirements, electrical requirements, and certification standards prior to installation.
Certification services are available throughout New England through AIE Laboratory Services, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.
Certification requirements may vary depending on laboratory protocols, facility standards, and application requirements.
Biosafety cabinets are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, exhaust compatibility, electrical compatibility, and final cabinet placement before shipment.
Because this is a ducted Class II Type B2 biosafety cabinet, installation should be coordinated with facility engineering personnel or qualified biosafety cabinet service providers to confirm proper exhaust integration and airflow performance.
Depending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.
A Type B2 biosafety cabinet exhausts 100% of cabinet airflow through a dedicated facility exhaust system without internal recirculation. Type A2 cabinets recirculate a large percentage of filtered air back into the workspace.
The NU-430-400 provides total exhaust containment capability in a more compact 4-foot footprint. Many laboratories prefer smaller B2 cabinets when laboratory space is limited or when workflows do not require a larger 5-foot or 6-foot workspace.
Yes. The NU-430-400 is a hard-ducted Class II Type B2 biosafety cabinet and must be connected to an appropriate facility exhaust system before operation and certification.
Type B2 biosafety cabinets are commonly used for hazardous drug preparation, pharmaceutical compounding, microbiology workflows involving volatile toxic chemicals, radionuclide applications, and laboratory procedures requiring maximum exhaust containment.
American Instrument Exchange technicians inspect blower systems, airflow performance, cabinet controls, sash operation, lighting systems, and overall cabinet condition prior to shipment. Unless otherwise specified, new HEPA filters are installed before delivery.
Yes. Certification services are available through AIE Laboratory Services, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support.
Yes. A 90-day warranty from American Instrument Exchange is included.
Yes. Buyers should confirm exhaust compatibility, airflow requirements, electrical compatibility, doorway clearances, and final cabinet placement prior to shipment and installation.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.