NuAire PharmaGard NU-NTE797-400 Isolator
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The NuAire PharmaGard NU-NTE797-400 is a 4-foot negative-pressure, total-exhaust Compounding Aseptic Containment Isolator designed for sterile compounding of hazardous drugs, including chemotherapy medications and other pharmaceutical preparations requiring both aseptic conditions and enhanced personnel containment.
Unlike a positive-pressure compounding isolator intended primarily for non-hazardous sterile preparations, the PharmaGard NTE797 maintains its work area under negative pressure. This helps prevent hazardous airborne contaminants from escaping the isolator while HEPA-filtered unidirectional airflow maintains an ISO Class 5 environment for sterile compounding.
The NU-NTE797-400 uses a total-exhaust design. Air passing through the work area is exhausted through HEPA filtration rather than recirculated within the cabinet, and contaminated ducts and plenums are maintained under negative pressure. The system requires connection to an appropriate facility exhaust system.
A separate negative-pressure interchange chamber allows medications, supplies, and other materials to be transferred into and out of the primary work area while helping maintain both containment and cleanliness. The work zone and interchange receive HEPA-filtered unidirectional airflow at approximately 20 air changes per minute.
With a welded Type 304 stainless steel pressure-tight enclosure, glove-port access, hinged polycarbonate viewing window, removable stainless steel work tray, hospital-grade electrical outlet, pressure monitoring, and approximately 35.25-inch-wide primary work zone, the 4-foot NTE797-400 provides a compact hazardous-drug compounding station for hospital pharmacies, oncology pharmacies, healthcare facilities, and pharmaceutical research environments.
This NuAire PharmaGard NU-NTE797-400 is used and refurbished by American Instrument Exchange. AIE technicians inspect and test the isolator and installed systems before shipment. The unit is thoroughly cleaned and includes a 90-day warranty.
NuAire PharmaGard model NU-NTE797-400
4-foot Compounding Aseptic Containment Isolator
Negative-pressure design for hazardous-drug containment
Total-exhaust airflow configuration
Designed for aseptic compounding of hazardous and chemotherapy drugs
ISO Class 5 HEPA-filtered work zone
ISO Class 5 HEPA-filtered interchange chamber
Approximately 20 HEPA-filtered air changes per minute
99.99% efficient supply and exhaust HEPA filtration
Welded Type 304 stainless steel pressure-tight construction
Separate negative-pressure interchange chamber
Large oval glove ports
Flexible sleeve and glove system
Hinged polycarbonate viewing window
Removable stainless steel work tray
Pressure monitoring
Hospital-grade duplex outlet
115 V, 60 Hz electrical configuration
Used and refurbished by American Instrument Exchange
90-day warranty included
Sterile hazardous-drug compounding presents two simultaneous challenges.
The compounded preparation must be protected from environmental contamination, while pharmacists and technicians must be protected from potentially hazardous drugs, aerosols, powders, droplets, and residues generated during compounding.
A positive-pressure sterile environment is useful for product protection, but positive pressure is generally undesirable when hazardous compounds are involved because leakage tends to move outward.
The NuAire NTE797 takes the opposite approach.
Its primary work area operates under negative pressure relative to the surrounding environment, helping ensure that leakage is directed inward rather than allowing hazardous material to migrate into the pharmacy.
At the same time, HEPA-filtered unidirectional supply air creates an ISO Class 5 work environment for aseptic preparation.
The result is a physical barrier system designed to combine sterile compounding conditions with hazardous-drug containment.
The NuAire PharmaGard NTE797-400 is designed primarily for sterile hazardous-drug compounding, including preparation of chemotherapy medications, antineoplastic drugs, hazardous injectable preparations, and other sterile pharmaceutical compounds requiring negative-pressure containment.
It may also be useful in pharmaceutical research, hospital pharmacy operations, oncology centers, compounding pharmacies, veterinary oncology pharmacies, and healthcare research facilities handling sterile hazardous preparations.
The suitability of a particular legacy NTE797 installation should be evaluated against the facility's current procedures, risk assessment, certification requirements, and applicable pharmacy standards.
The NTE797-400 is best suited to hospital pharmacies, oncology pharmacies, healthcare facilities, sterile compounding pharmacies, pharmaceutical research laboratories, cancer treatment centers, veterinary oncology facilities, academic medical centers, and other environments where sterile hazardous preparations are compounded.
Its nominal 4-foot width provides a relatively compact footprint while retaining a separate transfer chamber and substantial primary work area.
| Specification | Details |
|---|---|
| Manufacturer | NuAire |
| Product Family | PharmaGard |
| Model | NU-NTE797-400 |
| Equipment Type | Compounding Aseptic Containment Isolator |
| Nominal Width | 4 ft |
| Pressure Configuration | Negative Pressure |
| Exhaust Configuration | Total Exhaust |
| Primary Application | Sterile Hazardous-Drug Compounding |
| Work Zone Cleanliness | ISO Class 5 |
| Interchange Cleanliness | ISO Class 5 |
| Airflow | HEPA-Filtered Unidirectional |
| Air Changes | Approx. 20 per Minute |
| Supply HEPA Efficiency | 99.99% at 0.3 Micron |
| Exhaust HEPA Efficiency | 99.99% at 0.3 Micron |
| Exterior Dimensions | Approx. 50"W × 32.5"D × 61"H |
| Work Zone Dimensions | Approx. 35.25"W × 23.25"D × 27.375"H |
| Interchange Dimensions | Approx. 14.125"W × 24"D × 27.375"H |
| Standard Exhaust Requirement | Approx. 425 CFM |
| Required Duct Static Pressure | Approx. 2.0" w.g. |
| Construction | Welded 16-Gauge Type 304 Stainless Steel |
| Viewing Window | Hinged, Lockable Polycarbonate |
| Glove Access | Flexible Sleeve / Glove System |
| Electrical | 115 V, 60 Hz |
| Blower / Lights | Approx. 3 A |
| Duplex Outlet Capacity | Approx. 3 A |
| Total Electrical Load | Approx. 6 A |
| Power Cord | 12' Hospital Grade |
| Net Weight | Approx. 465 lb |
| Crated Shipping Weight | Approx. 515 lb |
| Heat Rejection | Approx. 539 BTU/hr |
| Safety Listing | UL / UL-C |
| Condition | Used / Refurbished |
| Warranty | 90 Days from American Instrument Exchange |
Negative pressure is one of the defining characteristics of the NTE797.
The work chamber operates below room pressure so that air tends to move into the isolator rather than outward through potential leakage paths.
This pressure relationship is important when handling hazardous pharmaceutical compounds.
If an aerosol, droplet, or particulate contaminant is generated during compounding, the negative-pressure environment helps prevent that contaminant from migrating into the surrounding pharmacy.
The enclosure's pressure-tight construction, glove access, HEPA filtration, and facility exhaust connection work together as an integrated containment system.
The NTE in NU-NTE797 identifies an important characteristic of this PharmaGard configuration: it is a negative-pressure total-exhaust isolator.
Air passing through the contaminated work area is exhausted from the cabinet rather than recirculated back through the work zone.
The total-exhaust approach is particularly useful for hazardous-drug applications because contaminants removed from the work area are directed through exhaust HEPA filtration and then into the facility exhaust system.
This distinguishes the NTE797 from recirculating isolator configurations.
The NTE797-400 requires connection to an appropriate building exhaust system.
NuAire specifies approximately 425 CFM exhaust for the 4-foot configuration at approximately 2.0 inches water-gauge static pressure.
The facility exhaust blower should be located and configured so contaminated ductwork remains under negative pressure.
Duct size, length, elbows, transitions, static-pressure losses, discharge location, and building HVAC conditions all need to be considered when installing the isolator.
This is not a plug-in recirculating glove box that can simply be placed on a laboratory bench and operated without exhaust infrastructure.
The primary compounding chamber provides HEPA-filtered unidirectional airflow designed to maintain ISO Class 5 conditions.
This clean-air environment is essential for aseptic compounding because it helps protect sterile preparations from airborne particulate contamination.
Filtered supply air continuously sweeps through the work area before entering the exhaust pathway.
Maintaining ISO Class 5 conditions depends on correct airflow, filter integrity, certification, cleaning practices, glove integrity, operator technique, and proper material transfer procedures.
The interchange chamber is also supplied with HEPA-filtered air and designed to maintain ISO Class 5 conditions.
This allows materials to be transferred into and out of the work area through a controlled environment rather than directly opening the primary chamber to the surrounding room.
Internal and external sealed doors separate the interchange from the work zone and pharmacy.
Proper transfer procedures are essential to maintaining both containment and aseptic conditions.
The NTE797 uses pressure relationships between the surrounding room, interchange, and primary work chamber to support hazardous-drug containment.
Both internal areas remain under negative pressure relative to the room.
The pressure arrangement helps prevent hazardous material from escaping outward while the separate interchange reduces the environmental disruption associated with introducing supplies.
Pressure should be monitored and verified during certification because proper differential pressure is fundamental to the isolator's performance.
A Minihelic gauge provides an indication of negative static pressure within the main chamber.
During normal operation, the work chamber is maintained under negative pressure.
Monitoring chamber pressure gives technicians and operators a direct indication that the isolator is operating within its intended pressure relationship.
Unexpected changes in pressure may indicate exhaust problems, filter loading, open doors, airflow imbalance, or another condition requiring investigation.
The NTE797 platform also incorporates a PharmaGard digital monitoring system that uses a pressure transducer to monitor negative pressure.
The monitor provides visual status information for acceptable operation, approaching alarm conditions, and alarm conditions.
This gives the operator an additional means of identifying changes that could compromise containment.
Alarm conditions should be investigated before hazardous compounding continues.
Incoming supply air passes through a HEPA filter rated 99.99% efficient at 0.3 micron.
HEPA filtration removes airborne particulate contamination from the supply air before it reaches the sterile work area.
This filtration contributes to the ISO Class 5 environment required for aseptic preparation.
The supply filter is maintained under negative pressure within the isolator's filter-seal system.
Contaminated air leaving the work area passes through exhaust HEPA filtration before entering the facility exhaust system.
The exhaust HEPA filter is also rated 99.99% efficient at 0.3 micron.
This filtration provides an important layer of containment for hazardous-drug particulates and aerosols.
HEPA filters do not capture all chemical vapors or gases, which is one reason the total-exhaust configuration is particularly useful for hazardous-drug applications.
NuAire designed the NTE797 to provide approximately 20 HEPA-filtered air changes per minute within both the work zone and interchange.
The high rate of filtered air exchange helps maintain clean conditions and remove airborne contaminants from the work area.
Airflow must remain correctly balanced with the facility exhaust system to preserve both the ISO Class 5 environment and the required negative pressure.
The PharmaGard uses HEPA-filtered unidirectional supply airflow across the work area.
Maintaining organized airflow reduces turbulence and helps continuously sweep airborne contamination away from critical compounding areas.
Operators should avoid unnecessary obstruction of airflow pathways with supplies, waste, or equipment.
Good compounding technique remains essential even when working inside an isolator.
The NTE797 uses welded 16-gauge Type 304 stainless steel pressure-tight construction.
Stainless steel provides a durable, cleanable surface appropriate for pharmacy environments and repeated disinfection.
Welded construction also minimizes joints and potential leakage pathways in the containment envelope.
The interior includes a removable stainless steel work tray that facilitates cleaning and access to the spill area beneath the work surface.
Hazardous-drug compounding can involve accidental spills or leakage from syringes, vials, tubing, or other components.
The PharmaGard incorporates a work-surface and spill-trough arrangement intended to help contain liquids within the isolator.
A drain valve facilitates appropriate management of collected material.
Spills involving hazardous drugs should always be managed according to the facility's established hazardous-drug spill procedures.
Operators work through glove ports rather than placing their arms directly into an open cabinet.
This physical barrier is one of the principal differences between a compounding isolator and a conventional biological safety cabinet.
Flexible sleeves and gloves allow pharmacists and technicians to manipulate syringes, vials, IV bags, and other materials while maintaining separation between the operator and controlled work environment.
Gloves and sleeves should be inspected routinely and replaced if punctured, torn, degraded, or otherwise compromised.
NuAire designed the PharmaGard with large oval glove ports to provide access throughout the work area.
The shape helps improve reach and ergonomics during repeated compounding procedures.
Good ergonomics can be particularly important in high-volume pharmacy environments where technicians may perform repetitive manipulations for extended periods.
A large polycarbonate viewing window provides clear visibility throughout the work area.
The window is hinged and can be opened when necessary for cleaning, maintenance, or equipment access.
During normal hazardous-drug compounding, the window remains closed and locked so the pressure-tight barrier and glove-access system can provide the intended containment.
The interchange chamber allows medications, supplies, and other materials to enter or leave the isolator without directly opening the main compounding chamber to the surrounding pharmacy.
This supports both product protection and hazardous-drug containment.
The interchange measures approximately 14.125 inches wide × 24 inches deep × 27.375 inches high.
A sliding work tray helps move materials between the interchange and main work zone.
The NTE797 was purpose-built for hazardous pharmaceutical compounding.
Hazardous drugs can present occupational exposure risks through aerosols, droplets, powders, contaminated surfaces, and accidental releases.
The isolator provides multiple layers of protection: a physical enclosure, negative pressure, glove access, HEPA-filtered airflow, HEPA-filtered exhaust, controlled transfer, and total external exhaust.
These engineering controls must be combined with appropriate pharmacy procedures, personal protective equipment, cleaning, certification, and facility design.
Antineoplastic and chemotherapy medications are a primary application for negative-pressure compounding containment isolators.
Preparation can involve transferring concentrated medications between vials, syringes, infusion bags, and other containers.
Aerosols or droplets generated during these procedures should be contained rather than released into the pharmacy.
The NTE797's negative-pressure work chamber and total-exhaust design were developed specifically for this type of sterile hazardous-drug workflow.
Containment is only one half of the NTE797's function.
The system must also protect the sterile preparation from contamination.
HEPA-filtered unidirectional airflow provides the ISO Class 5 work environment required for aseptic procedures when the isolator is correctly installed, certified, maintained, and operated.
This combination of product protection and hazardous-drug containment distinguishes a CACI from a simple negative-pressure glove box.
The NTE797 is designed to address three protection objectives.
The ISO Class 5 environment helps protect the compounded product.
Negative pressure and physical glovebox separation help protect pharmacy personnel.
HEPA-filtered total exhaust and negative-pressure contaminated plenums help protect the surrounding environment.
Maintaining all three protections depends on correct installation and ongoing certification.
The distinction between these two PharmaGard models is especially important.
The NU-PR797-400 is a positive-pressure, recirculating Compounding Aseptic Isolator intended for sterile non-hazardous preparations.
The NU-NTE797-400 is a negative-pressure, total-exhaust Compounding Aseptic Containment Isolator intended for sterile hazardous-drug compounding.
A positive-pressure PR797 should not be substituted for the NTE797 when negative-pressure hazardous-drug containment is required.
Both a negative-pressure compounding isolator and an appropriate Class II biological safety cabinet can be used within pharmaceutical containment strategies, but their designs differ substantially.
The NTE797 uses a closed barrier with glove ports and a controlled interchange chamber.
A biosafety cabinet uses an open front with carefully controlled inflow and downflow air.
The appropriate Primary Engineering Control depends on the pharmacy workflow, facility design, current standards, risk assessment, and certification requirements.
The NTE797 should not be considered a general laboratory glove box.
It was specifically engineered around sterile hazardous-drug compounding.
Its ISO Class 5 unidirectional airflow, negative-pressure cascade, HEPA filtration, total exhaust, pharmacy-oriented work zone, interchange chamber, glove ports, and stainless steel construction distinguish it from glove boxes intended for inert-atmosphere chemistry or simple material isolation.
The NU-NTE797 is a legacy PharmaGard model originally designed around the sterile compounding and hazardous-drug practices applicable during its production period.
NuAire's current negative-pressure PharmaGard product family has evolved, including newer models specifically engineered around current USP <800> hazardous-drug requirements.
A used NTE797 should therefore not be assumed to satisfy every current USP <797>, USP <800>, state pharmacy, accreditation, or facility requirement solely because of its original design.
Facilities considering a refurbished NTE797 for regulated pharmacy compounding should have the proposed installation and application evaluated against current requirements and should arrange appropriate certification after installation.
Containment isolators depend on correct airflow, HEPA filter integrity, chamber pressure, exhaust balance, and physical barrier integrity.
For this reason, certification after installation is an essential part of putting a refurbished isolator into service.
Testing should evaluate the system according to the facility's applicable standards and intended use.
Certification requirements for regulated sterile compounding should be established by the pharmacy and qualified certification professionals.
Both supply and exhaust HEPA filters are critical to NTE797 performance.
Filter integrity testing helps verify that the filters and their seals are functioning correctly.
A damaged or leaking supply filter could compromise product protection, while a compromised exhaust filter could reduce hazardous-particulate containment.
Filter condition should therefore be evaluated as part of certification and preventative maintenance.
Because the NTE797-400 requires approximately 425 CFM of building exhaust at substantial static pressure, facility planning is important.
The exhaust system must be capable of maintaining required flow under actual duct conditions.
Duct losses, elbows, transitions, vertical runs, roof discharge, and other system components can affect performance.
The exhaust blower and duct system should be designed so contaminated ductwork within the building remains under negative pressure.
American Instrument Exchange inspects and tests used NuAire PharmaGard isolators before shipment.
For the NU-NTE797-400, AIE technicians inspect the stainless steel enclosure, viewing window, glove ports, sleeves, transfer chamber, work tray, controls, pressure monitoring, electrical components, lighting, HEPA filter housings, blower components, alarms, and other installed systems.
Accessible interior and exterior surfaces are thoroughly cleaned.
Because final isolator performance depends on the building exhaust system and installation conditions, site certification should be completed after the NTE797 is installed and connected to its permanent exhaust system.
Hazardous-drug compounding isolators are highly specialized pieces of pharmacy equipment.
The NTE797-400 combines a pressure-tight stainless steel enclosure, negative-pressure containment, ISO Class 5 HEPA-filtered airflow, a controlled interchange, total exhaust, glove-port access, pressure monitoring, and pharmacy-specific ergonomics in one compact 4-foot system.
For facilities where the model remains appropriate for the intended application and current regulatory requirements, purchasing a used and refurbished NTE797-400 can significantly reduce the acquisition cost compared with new pharmacy containment equipment.
American Instrument Exchange inspects, tests, and cleans the isolator before shipment and includes a 90-day warranty.
The NU-NTE797-400 is a substantial containment system weighing approximately 465 pounds before the addition of its supporting base.
The isolator measures approximately 50 inches wide × 32.5 inches deep × 61 inches high.
An appropriate stand or bench support must be provided.
The unit requires 115 V, 60 Hz electrical service and connection to a facility exhaust system capable of approximately 425 CFM at 2.0 inches water-gauge static pressure.
Before purchase, facilities should confirm doorway and elevator clearances, supporting structure, exhaust capacity, duct routing, electrical service, final working height, and access for future filter replacement and certification.
The isolator should be professionally installed, balanced, and certified before use for hazardous-drug compounding.
Facilities using a NuAire PharmaGard NU-NTE797-400 may also require biosafety cabinets, pharmacy refrigerators, laboratory refrigerators, laboratory freezers, ultra-low freezers, centrifuges, clean benches, chemical fume hoods, pharmaceutical isolators, and other equipment used for medication preparation, pharmaceutical research, and controlled laboratory workflows.
American Instrument Exchange supplies used and refurbished pharmacy containment equipment, biosafety cabinets, isolators, laboratory cold storage, and other equipment for hospitals, pharmacies, pharmaceutical companies, biotechnology facilities, academic medical centers, and research laboratories.
The NuAire PharmaGard NU-NTE797-400 is a 4-foot negative-pressure, total-exhaust Compounding Aseptic Containment Isolator designed for sterile compounding of hazardous pharmaceutical preparations.
Yes. Hazardous and chemotherapy drug compounding is a primary application of the NTE797.
Yes. Its primary work area and transfer system operate under negative-pressure conditions designed to help contain hazardous material.
Yes. Contaminated air is HEPA filtered and exhausted rather than recirculated through the work area.
Yes. The NTE797-400 must be connected to an appropriate facility exhaust system.
NuAire specifies approximately 425 CFM at 2.0 inches water-gauge static pressure for the standard 4-foot configuration.
Yes. NuAire designed the work zone to provide ISO Class 5 HEPA-filtered unidirectional airflow.
Yes. The transfer/interchange chamber is also designed to maintain ISO Class 5 conditions.
NuAire specifies approximately 20 HEPA-filtered air changes per minute within both the work zone and interchange.
Yes. Both supply and exhaust filtration are rated 99.99% efficient at 0.3 micron.
The isolator itself measures approximately 50"W × 32.5"D × 61"H.
The primary work area measures approximately 35.25"W × 23.25"D × 27.375"H.
The interchange measures approximately 14.125"W × 24"D × 27.375"H.
It allows materials to be transferred into and out of the controlled work area without directly opening the main compounding chamber to the surrounding room.
The enclosure uses welded 16-gauge Type 304 stainless steel pressure-tight construction.
Yes. Its HEPA-filtered ISO Class 5 work environment is designed to protect sterile compounded preparations from airborne particulate contamination.
Its negative-pressure, enclosed design is intended to help contain hazardous pharmaceutical contaminants and reduce operator exposure when properly installed, certified, and used.
The NTE797 is a negative-pressure total-exhaust containment isolator for hazardous-drug compounding. The PR797 is a positive-pressure recirculating isolator intended for sterile non-hazardous drug preparation.
No. It is a closed Compounding Aseptic Containment Isolator. Its barrier, glove-port, interchange, and airflow design differ from a Class II biosafety cabinet.
No. The total-exhaust NTE797 requires an appropriately designed external exhaust system.
The 4-foot NU-NTE797-400 operates on 115 V, 60 Hz power with an approximately 6 A total electrical rating.
NuAire specifies an approximate net isolator weight of 465 pounds, excluding the supporting base.
No. The NTE797 is a legacy model designed under standards applicable during its production period. A facility should evaluate the proposed installation against current USP requirements, state regulations, accreditation requirements, and its own procedures before using it for regulated compounding.
NuAire's current negative-pressure hazardous-drug isolator family includes newer PharmaGard CACI models designed around current USP <800> requirements.
Yes. Final performance depends on facility exhaust, airflow balance, filter integrity, chamber pressure, and installation conditions. Appropriate certification should be completed after installation and before regulated compounding.
Yes. This unit is used and refurbished by American Instrument Exchange.
AIE inspects the enclosure, transfer chamber, glove system, controls, pressure monitoring, lighting, electrical systems, filtration housings, blower components, alarms, and other installed features before shipment. Final airflow balancing and certification should be performed after installation.
Yes. American Instrument Exchange includes a 90-day warranty with this refurbished NuAire PharmaGard NU-NTE797-400.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.