NuAire PharmaGard NU-PR797-400 Isolator
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The NuAire PharmaGard NU-PR797-400 is a 4-foot positive-pressure Compounding Aseptic Isolator designed for sterile preparation of non-hazardous pharmaceutical compounds. Unlike negative-pressure containment isolators intended for hazardous drugs, the PR797 is engineered primarily around product protection. Its positive-pressure, HEPA-filtered environment helps prevent room contaminants from entering the isolator while providing an ISO Class 5 environment for sterile compounding.
The NU-PR797-400 uses a recirculating airflow design with HEPA-filtered unidirectional air supplied to both the primary work chamber and adjoining interchange chamber. Approximately 20 air changes per minute continuously sweep these areas with filtered air.
An important feature of the PharmaGard design is its positive-pressure cascade. The main work chamber operates at a higher positive pressure than the interchange chamber, while the interchange remains positively pressurized relative to the surrounding room. This staged pressure relationship helps prevent contaminants from migrating inward toward sterile preparations.
Because the PR797 recirculates HEPA-filtered air and is designed for sterile non-hazardous drug preparation, it does not require the high-volume facility exhaust connection associated with NuAire's negative-pressure total-exhaust hazardous-drug isolators.
This particular American Instrument Exchange NU-PR797-400 includes an adjustable-height stand, waste-disposal ports, and new gloves. The system is used and refurbished by AIE, inspected and tested before shipment, and includes a 90-day warranty.
NuAire PharmaGard model NU-PR797-400
4-foot Compounding Aseptic Isolator
Positive-pressure design for sterile non-hazardous drug compounding
Recirculating HEPA-filtered airflow
ISO Class 5 primary work chamber
ISO Class 5 interchange chamber
Approximately 20 HEPA-filtered air changes per minute
Positive-pressure cascade from work chamber to interchange to room
HEPA-filtered unidirectional airflow
Welded Type 304 stainless steel pressure-tight enclosure
Two glove ports with flexible sleeves and gloves
Separate controlled interchange chamber
Sliding interchange work tray
Hinged polycarbonate viewing window
Pressure monitoring for work and interchange chambers
Adjustable-height stand included with this AIE unit
Waste-disposal ports included
New gloves included
115 V, 60 Hz electrical configuration
Used and refurbished by American Instrument Exchange
90-day warranty included
Sterile pharmaceutical compounding requires protection of the preparation from microorganisms, airborne particles, and other sources of contamination.
The NuAire PharmaGard PR797 creates an enclosed, HEPA-filtered environment specifically designed around this requirement.
Rather than relying on an open-front clean-air workspace, the PharmaGard physically separates the operator from the controlled environment using a sealed enclosure, glove ports, and a separate transfer chamber.
The work chamber is maintained at positive pressure relative to the surrounding room.
If small leakage paths exist, the pressure differential encourages clean filtered air to move outward rather than allowing potentially contaminated room air to enter the sterile work area.
NuAire further divides the interior into two pressure zones. The primary work chamber operates at a higher positive pressure than the adjoining interchange, creating a pressure cascade that provides additional protection for the critical compounding area.
The NuAire PharmaGard NU-PR797-400 is designed for sterile compounding of non-hazardous medications and pharmaceutical preparations.
Typical applications include preparation of sterile injectable medications, IV admixtures, parenteral nutrition solutions, antibiotic preparations, ophthalmic medications, sterile irrigation solutions, and other non-hazardous compounded sterile preparations.
The system is particularly useful when a pharmacy wants the physical separation and controlled material-transfer advantages of an isolator rather than an open-front primary engineering control.
The PR797-400 is well suited to hospital pharmacies, healthcare systems, sterile compounding pharmacies, ambulatory care facilities, academic medical centers, pharmaceutical research environments, veterinary pharmacies, and other facilities preparing sterile non-hazardous pharmaceutical products.
Its nominal 4-foot size provides a relatively compact footprint while maintaining a separate ISO Class 5 interchange and a substantial primary compounding area.
| Specification | Details |
|---|---|
| Manufacturer | NuAire |
| Product Family | PharmaGard |
| Model | NU-PR797-400 |
| AIE Inventory Number | 2742C |
| Equipment Type | Compounding Aseptic Isolator (CAI) |
| Nominal Width | 4 ft |
| Pressure Configuration | Positive Pressure |
| Airflow Configuration | Recirculating |
| Primary Application | Sterile Non-Hazardous Drug Compounding |
| Work Zone Classification | ISO Class 5 |
| Interchange Classification | ISO Class 5 |
| Airflow | HEPA-Filtered Unidirectional |
| Air Changes | Approx. 20 per Minute |
| Supply HEPA Efficiency | 99.99% at 0.3 Micron |
| Enclosure Construction | Welded 16-Gauge Type 304 Stainless Steel |
| Work Zone Dimensions | Approx. 35.25"W × 23.25"D × 27.375"H |
| Interchange Dimensions | Approx. 14.125"W × 24"D × 27.375"H |
| Overall Isolator Dimensions | Approx. 50"W × 32.5"D × 48"H |
| Viewing Window | Hinged Polycarbonate |
| Glove Ports | Two |
| Internal Electrical Outlet | Hospital-Grade Duplex |
| Electrical | 115 V, 60 Hz |
| Blower / Lighting Load | Approx. 3 A |
| Internal Outlet Capacity | Approx. 3 A |
| Total Electrical Load | Approx. 6 A |
| Heat Rejection | Approx. 539 BTU/hr |
| Net Isolator Weight | Approx. 425 lb |
| Stand | Adjustable-Height Stand Included with AIE Unit |
| Waste Disposal Ports | Included with AIE Unit |
| Gloves | New Gloves Included |
| Condition | Used / Refurbished |
| Warranty | 90 Days from American Instrument Exchange |
Positive pressure is the defining characteristic of the NU-PR797.
The controlled environment inside the isolator operates above the pressure of the surrounding room.
This means the natural direction of leakage is outward.
Potentially contaminated room air is therefore discouraged from entering through small leakage paths and reaching sterile preparations.
This design makes positive pressure particularly appropriate for non-hazardous sterile compounding, where protecting the medication from environmental contamination is the primary airflow objective.
NuAire takes the positive-pressure concept one step further by establishing different pressure levels within the isolator.
The main compounding chamber operates at the highest positive pressure.
The adjoining interchange chamber is also positively pressurized relative to the room, but at a lower pressure than the main work chamber.
The resulting pressure relationship is:
Work Chamber → Interchange Chamber → Surrounding Room
This means airflow naturally tends to move away from the most critical sterile compounding zone.
When the internal interchange door is opened, the higher pressure in the work chamber helps prevent contaminants from the interchange from migrating toward the critical compounding area.
The primary work chamber provides HEPA-filtered unidirectional airflow designed to maintain ISO Class 5 conditions.
Maintaining this level of airborne particulate cleanliness is fundamental to aseptic pharmaceutical compounding.
Filtered air continuously moves through the work area, helping sweep airborne contamination away from critical sites.
Proper technique remains essential. Operators should avoid blocking airflow pathways or placing unnecessary materials within the work chamber.
The interchange is also designed to maintain ISO Class 5 conditions.
This is an important advantage over a simple pass-through chamber.
Materials entering the isolator move first into a HEPA-filtered controlled environment before being transferred into the primary work area.
The positive-pressure relationship between the two chambers provides an additional level of protection for the primary compounding zone.
NuAire specifies approximately 20 HEPA-filtered air changes per minute within both the primary work zone and interchange chamber.
This continuous supply of filtered air helps maintain ISO Class 5 conditions and minimize cross-contamination.
The system is designed around true unidirectional airflow rather than simply mixing filtered air throughout the chamber.
The PR797 differs significantly from a total-exhaust isolator.
After HEPA-filtered supply air passes through the work area, the airflow is divided toward the front and rear, moves beneath the work tray and through the rear airflow pathway, and is recirculated through the supply filtration system.
Additional HEPA-filtered room air is introduced to maintain positive pressure.
This recirculating design reduces the facility infrastructure required for installation compared with a total-exhaust isolator.
Because the PR797 is a positive-pressure recirculating isolator for non-hazardous drugs, it does not require the approximately 425 CFM hard-ducted exhaust connection associated with the 4-foot negative-pressure NTE797 total-exhaust model.
This can significantly simplify installation.
Facilities still need to evaluate room HVAC, heat load, placement, electrical service, and applicable pharmacy requirements, but the PR797 does not depend on a high-static-pressure building exhaust system for its basic airflow operation.
Supply air passes through high-efficiency particulate air filtration before entering the controlled work environment.
The HEPA filter removes airborne particles that could otherwise contaminate sterile preparations.
Maintaining filter integrity is therefore essential to the product-protection function of the isolator.
HEPA filter integrity should be evaluated during certification and after filter replacement or other service that could affect the filtration system.
The PR797 uses unidirectional HEPA-filtered airflow within both controlled chambers.
Organized airflow helps move airborne particles away from critical preparation sites while reducing turbulence and cross-contamination.
Materials should be arranged so they do not unnecessarily obstruct airflow.
Even inside an isolator, good aseptic technique and appropriate material placement remain essential.
A major distinction between the PharmaGard and an open-front laminar airflow workbench is the physical barrier separating the operator from the controlled environment.
The user performs compounding procedures through integrated glove ports.
This reduces direct interaction between room air, personnel, and the sterile work zone.
The barrier design also allows the isolator to maintain a controlled pressure relationship independent of many of the airflow disturbances associated with an open front.
Two glove ports provide access to the main compounding chamber.
Flexible sleeves and gloves allow pharmacists and technicians to manipulate syringes, vials, IV bags, tubing, and other materials without opening the work area.
This helps maintain the controlled internal environment throughout normal compounding operations.
Gloves should be inspected routinely for tears, punctures, deterioration, or other damage.
This AIE unit includes new gloves.
Materials enter and leave the isolator through the separate interchange chamber.
Internal and external sealed doors isolate the interchange from both the primary work zone and surrounding room.
The chamber allows medications, supplies, syringes, IV bags, and other materials to be introduced without opening the main compounding chamber directly to the pharmacy.
This controlled transfer process is central to maintaining the isolator's pressure cascade and ISO Class 5 environment.
The interchange incorporates a sliding work tray that facilitates movement of materials between the transfer chamber and primary work zone.
This allows operators to transfer supplies while minimizing awkward manipulation through the glove ports.
The tray and transfer surfaces should be cleaned according to the pharmacy's established procedures.
The PharmaGard provides pressure monitoring so operators can verify the pressure relationship between the controlled environment and surrounding room.
Pressure monitoring is particularly important because positive pressure is fundamental to the PR797's product-protection strategy.
A loss of appropriate positive pressure may indicate blower problems, filter loading, open doors, damaged seals, or another condition requiring investigation.
The interchange pressure is also monitored.
This allows personnel to confirm that the intended pressure cascade is being maintained.
Both the main chamber and interchange should remain appropriately pressurized during normal operation.
Changes in either chamber's pressure can affect the direction of airflow when the internal transfer door is opened.
The NU-PR797 uses welded 16-gauge Type 304 stainless steel pressure-tight construction.
Stainless steel provides a durable, cleanable surface suitable for repeated pharmacy cleaning and disinfection.
Welded construction reduces joints and potential leakage paths while creating a robust barrier around the controlled environment.
The stainless interior also withstands the repeated cleaning required in sterile compounding workflows.
A large transparent polycarbonate front window provides visibility across the primary work area.
The window is hinged so it can be opened for cleaning, maintenance, and equipment access.
During normal operation, the window remains closed so the isolator can maintain its positive-pressure environment.
The clear window allows pharmacists and technicians to maintain visual contact with materials and equipment throughout the compounding process.
The most important application distinction for the PR797 is that it is designed for sterile, non-hazardous pharmaceutical preparations.
The positive-pressure airflow configuration prioritizes protection of the preparation from environmental contamination.
Examples may include appropriate sterile IV admixtures, antibiotics, parenteral nutrition preparations, ophthalmic preparations, and other non-hazardous compounded sterile products.
The pharmacy remains responsible for determining whether each drug and procedure is appropriate for a positive-pressure CAI.
The enclosed ISO Class 5 work zone can support preparation of appropriate sterile IV medications.
Glove-port access allows technicians to manipulate vials, syringes, needles, IV bags, and transfer devices without exposing the critical work area directly to room air.
The barrier and positive-pressure environment provide an alternative workflow to open-front laminar airflow workstations.
Appropriate non-hazardous parenteral nutrition preparations can also be supported within the PR797.
The spacious work area provides room for bags, syringes, containers, and other necessary components.
An IV bar can support hanging containers during preparation.
The exact workflow should be established according to facility procedures and current sterile compounding requirements.
The PR797 may also support appropriate sterile ophthalmic medications, irrigation solutions, and other non-hazardous preparations requiring an ISO Class 5 primary engineering control.
The isolator does not determine whether a particular formulation is suitable for compounding. That decision remains part of the pharmacy's professional, regulatory, and procedural responsibilities.
This particular AIE NU-PR797-400 includes waste-disposal ports.
Integrated waste handling can reduce the need to move used materials back through the normal transfer pathway.
This can simplify workflow and help maintain organization within the controlled environment.
Waste disposal should follow the pharmacy's procedures for the materials being handled.
This AIE unit includes an adjustable-height stand.
An adjustable stand can improve ergonomics by allowing the glove-port and work-surface height to be better matched to individual operators.
This is particularly useful in pharmacies where several technicians of different heights use the same isolator.
Proper working height can reduce shoulder, arm, and back strain during repetitive compounding procedures.
A hospital-grade duplex outlet is provided on the rear wall of the work area.
This allows compatible equipment to be powered inside the isolator.
NuAire specifies approximately 3 A of available capacity for the internal duplex outlet on the standard 115 V configuration.
Equipment introduced into the controlled work zone should be suitable for the environment and should not obstruct critical airflow.
The difference between the PR797 and NTE797 is essential when selecting a PharmaGard isolator.
The NU-PR797 is positive pressure, recirculating, and intended for sterile non-hazardous drug preparation.
The NU-NTE797 is negative pressure, total exhaust, and designed for sterile hazardous-drug compounding.
The PR797 prioritizes protection of the sterile product from the surrounding environment.
The NTE797 additionally prioritizes containment of hazardous material to protect personnel and the environment.
These two isolators should not be treated as interchangeable.
The PR797 remains a positive-pressure CAI for sterile non-hazardous drug compounding.
For hazardous-drug compounding, negative-pressure Compounding Aseptic Containment Isolators are required instead.
NuAire's hazardous-drug PharmaGard family includes negative-pressure configurations specifically designed for those applications.
A PR797 should not be selected merely because it provides ISO Class 5 conditions if the drug being compounded requires hazardous-drug containment.
A laminar airflow workbench provides HEPA-filtered clean air over an open work area.
The PR797 adds a physical barrier between the operator and sterile compounding environment.
Glove ports replace direct open-front access, while a controlled interchange manages material transfer.
The isolator can therefore maintain a distinct controlled internal environment with a positive-pressure cascade.
Both approaches can provide ISO Class 5 environments when appropriately designed, installed, certified, and used, but their workflows and facility requirements differ.
A Class II biological safety cabinet uses open-front inflow and HEPA-filtered downflow to provide product, personnel, and environmental protection for appropriate biological applications.
The PR797 is a closed positive-pressure Compounding Aseptic Isolator designed primarily for sterile non-hazardous pharmaceutical compounding.
Because the PR797 maintains positive pressure, it should not be treated as a hazardous-drug containment substitute for an appropriate negative-pressure engineering control.
The PharmaGard PR797 is much more specialized than a general-purpose laboratory glove box.
A conventional glove box may simply isolate materials from the room or maintain a controlled gas atmosphere.
The PR797 incorporates pharmacy-specific HEPA-filtered unidirectional airflow, ISO Class 5 work and transfer environments, positive-pressure staging, glove-port access, pressure monitoring, stainless steel construction, and controlled material transfer.
It is best described as a Compounding Aseptic Isolator rather than simply a glove box.
This distinction is particularly important when selecting the PR797.
Positive pressure is excellent for protecting sterile non-hazardous preparations because contaminants in the room are discouraged from entering the isolator.
The same pressure direction is not appropriate when the primary concern is containing hazardous pharmaceutical contamination.
A hazardous compound should not automatically be handled in the PR797 simply because the system provides an ISO Class 5 sterile environment.
Hazard assessment and pharmacy requirements determine the appropriate engineering control.
NuAire designed the PR797 specifically as a Compounding Aseptic Isolator for sterile non-hazardous drug compounding under USP <797> workflows.
The isolator provides an ISO Class 5 primary engineering control when appropriately installed, certified, maintained, cleaned, and operated.
Compliance of an individual pharmacy involves considerably more than the equipment itself.
Facility design, placement, environmental monitoring, certification, cleaning procedures, beyond-use dating, personnel training, garbing, material transfer, and other requirements must all be addressed according to current standards.
A refurbished PharmaGard should be appropriately certified after installation before being placed into regulated sterile compounding service.
Certification verifies factors such as HEPA filter integrity, airflow velocity and uniformity, chamber pressure, pressure cascade, particulate cleanliness, and other performance characteristics.
Final performance can be influenced by installation conditions, room HVAC, filter condition, maintenance, and equipment placement.
Regular recertification should follow applicable pharmacy standards and facility procedures.
The supply HEPA filtration system is critical to maintaining ISO Class 5 conditions.
Filter leaks or damaged seals can allow contamination into the sterile environment.
HEPA filter integrity testing should therefore form part of appropriate certification and preventative maintenance.
Filters should also be evaluated after relocation or service that could affect their integrity.
The stainless steel interior, removable work surfaces, viewing window, gloves, interchange, and other exposed surfaces require regular cleaning and disinfection according to the pharmacy's established procedures.
The barrier system reduces direct environmental exposure but does not eliminate the need for rigorous aseptic technique.
Material transfer, glove disinfection, surface cleaning, and operator practices remain important components of contamination control.
American Instrument Exchange inspects and tests used NuAire PharmaGard isolators before shipment.
For this NU-PR797-400, AIE technicians inspect the stainless steel enclosure, viewing window, glove ports, new gloves, interchange chamber, transfer mechanism, controls, pressure monitoring, blower operation, lighting, electrical components, HEPA filter housings, adjustable-height stand, waste-disposal system, and other installed components.
The glovebox is visually inspected for damaged seals, cracks, or other conditions that could affect chamber integrity.
AIE also performs pressure-decay testing to evaluate whether the enclosure maintains pressure appropriately.
Accessible interior and exterior surfaces are thoroughly cleaned before shipment.
Final site certification should be performed after installation before the isolator is placed into regulated sterile compounding service.
The NuAire PharmaGard PR797-400 combines a physical barrier, positive-pressure protection, HEPA-filtered unidirectional airflow, ISO Class 5 work and transfer areas, controlled material transfer, stainless steel construction, and pharmacy-oriented ergonomics in one compact 4-foot system.
For hospitals, pharmacies, healthcare facilities, and research organizations preparing sterile non-hazardous pharmaceutical products, purchasing a used and refurbished PharmaGard can significantly reduce the cost of acquiring a specialized Compounding Aseptic Isolator.
This particular AIE unit also includes an adjustable-height stand, waste-disposal ports, and new gloves.
American Instrument Exchange inspects, tests, and cleans the system before shipment and includes a 90-day warranty.
The NU-PR797-400 isolator itself measures approximately 50 inches wide × 32.5 inches deep × 48 inches high and weighs approximately 425 pounds before its supporting base is included.
This AIE unit includes an adjustable-height stand, which increases the installed overall dimensions and total system weight.
The isolator requires 115 V, 60 Hz electrical service.
Unlike the negative-pressure total-exhaust NTE797, the PR797 does not require a high-volume hard-ducted exhaust connection for normal operation.
Before delivery, customers should confirm doorway and elevator clearance, installed height, electrical service, room HVAC conditions, floor loading, service access, and sufficient space around the unit for cleaning, maintenance, and certification.
After installation, the system should be appropriately certified before use for regulated sterile compounding.
Facilities using a NuAire PharmaGard NU-PR797-400 may also require pharmacy refrigerators, laboratory refrigerators, laboratory freezers, ultra-low freezers, clean benches, biosafety cabinets, negative-pressure hazardous-drug isolators, centrifuges, pharmaceutical storage equipment, and other equipment supporting sterile pharmaceutical preparation.
American Instrument Exchange supplies used and refurbished pharmacy isolators, biosafety cabinets, clean benches, laboratory cold storage, and other equipment for hospitals, pharmacies, pharmaceutical companies, biotechnology facilities, academic medical centers, and research laboratories.
The NU-PR797-400 is a 4-foot positive-pressure Compounding Aseptic Isolator designed for sterile preparation of non-hazardous drugs.
Yes. Both the primary work chamber and interchange are maintained under positive pressure relative to the surrounding room.
Positive pressure helps prevent potentially contaminated room air from entering the sterile compounding environment.
The primary work chamber operates at the highest positive pressure, the interchange is at a lower positive pressure, and the surrounding room is at the lowest pressure. This encourages airflow away from the critical work zone.
Yes. It recirculates HEPA-filtered air through the controlled work environment.
The standard PR797 does not require the high-volume hard-ducted exhaust connection needed by a negative-pressure total-exhaust NTE797.
Yes. Both the work chamber and interchange are designed to provide ISO Class 5 HEPA-filtered environments.
NuAire specifies approximately 20 HEPA-filtered air changes per minute in both the work zone and interchange.
It is designed for sterile non-hazardous pharmaceutical preparations.
The PR797 is a positive-pressure CAI for non-hazardous sterile compounding. Hazardous drugs require an appropriate negative-pressure containment primary engineering control.
A CAI, such as the PR797, provides an aseptic environment for sterile non-hazardous compounding. A Compounding Aseptic Containment Isolator, or CACI, adds negative-pressure containment for hazardous-drug applications.
The PR797 is positive pressure and recirculating for sterile non-hazardous drugs. The NTE797 is negative pressure and total exhaust for sterile hazardous-drug compounding.
Yes. The ISO Class 5 interchange allows materials to enter and leave the controlled work environment without directly opening the primary compounding chamber to the room.
The work zone is approximately 35.25"W × 23.25"D × 27.375"H.
The interchange is approximately 14.125"W × 24"D × 27.375"H.
Yes. This particular American Instrument Exchange PR797-400 includes an adjustable-height stand.
Yes. AIE lists this unit with new gloves.
Yes. Waste-disposal ports are included on this particular AIE unit.
Yes. A hospital-grade duplex outlet is located on the back wall of the work area.
No. It is a closed positive-pressure Compounding Aseptic Isolator specifically designed for sterile pharmaceutical compounding.
No. Although it uses glove-port access, the PR797 is specifically engineered as a pharmacy Compounding Aseptic Isolator.
Yes. Appropriate sterile non-hazardous IV preparations are a principal application of the PR797.
It may be used for appropriate sterile non-hazardous parenteral nutrition preparations when incorporated into a compliant pharmacy workflow.
NuAire designs and markets the PR797 specifically for sterile non-hazardous compounding under USP <797>. Compliance of an actual pharmacy installation also depends on certification, facility design, procedures, environmental monitoring, personnel practices, and other applicable requirements.
No. The PR797 is a positive-pressure CAI for sterile non-hazardous preparations. NuAire uses negative-pressure CACI models for hazardous-drug applications.
Yes. Appropriate site certification should be completed after installation and before the unit is used for regulated sterile compounding.
The standard four-foot model operates on 115 V, 60 Hz electrical service.
The isolator itself weighs approximately 425 pounds before the supporting base is added.
Yes. This unit is used and refurbished by American Instrument Exchange.
AIE technicians inspect the enclosure, glove system, transfer chamber, controls, pressure monitoring, blower, lighting, electrical systems, HEPA housings, stand, waste-disposal components, and other installed features. AIE also performs pressure-decay testing to evaluate chamber integrity.
Yes. American Instrument Exchange includes a 90-day warranty with this refurbished PharmaGard PR797-400.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.