The PerkinElmer N5374099 Intracooler is a specialized subambient cooling system designed for compatible PerkinElmer differential scanning calorimeters and thermal analysis instruments. Manufactured for PerkinElmer by PolyScience, the Intracooler provides closed-loop mechanical refrigeration that extends the low-temperature capabilities of compatible DSC and thermal analysis systems without requiring liquid nitrogen for routine subambient operation.
Available used and refurbished from American Instrument Exchange, the PerkinElmer N5374099 is designed for use with compatible PerkinElmer Pyris and legacy thermal analysis instruments. Depending on the instrument and configuration, PerkinElmer Intracooler systems can extend DSC operation to temperatures as low as approximately -65°C. A 90-day warranty is included.
Specialized subambient cooling system for thermal analysis
PerkinElmer model N5374099
Manufactured for PerkinElmer by PolyScience
Designed for compatible PerkinElmer DSC and thermal analyzers
Supports low-temperature DSC operation without routine liquid nitrogen cooling
Compatible with selected Pyris 1 DSC, Pyris 6 DSC, DSC 7, TMA 7, and DMA 7 systems
Closed-loop mechanical refrigeration
Automatic coolant circulation
Designed to connect directly to compatible analyzer cooling hardware
Compact floor or under-bench installation
230 V, 50/60 Hz configuration
Used, refurbished, and tested by American Instrument Exchange
90-day warranty included
The PerkinElmer N5374099 Intracooler differs substantially from a conventional laboratory recirculating chiller. Rather than serving as a general-purpose source of chilled fluid for multiple laboratory instruments, the Intracooler was engineered specifically to extend the subambient operating range of compatible PerkinElmer thermal analysis systems.
The system uses mechanical refrigeration and a dedicated circulating cooling arrangement to remove heat from the analyzer. When installed with the appropriate PerkinElmer hardware, the Intracooler allows thermal analysis experiments to begin substantially below room temperature.
This capability is particularly valuable in differential scanning calorimetry, where transitions such as glass transitions, crystallization events, melting behavior, and other thermal phenomena may occur below ambient temperature.
The N5374099 therefore should be evaluated primarily as a thermal-analysis accessory rather than as a conventional laboratory chiller.
| Specification | Details |
|---|---|
| Manufacturer | PerkinElmer |
| Manufactured By | PolyScience |
| Model / Part Number | N5374099 |
| Equipment Type | Thermal analyzer Intracooler |
| Cooling Type | Mechanical refrigeration |
| Application | Subambient thermal analysis |
| Compatible Instrument Family | Selected PerkinElmer Pyris and legacy thermal analyzers |
| DSC Operating Capability | Down to approximately -65°C with compatible Intracooler configuration |
| Coolant Operation | Closed-loop circulation |
| Exterior Dimensions | Approx. 15 in. W × 20 in. D × 22.25 in. H |
| Electrical Requirements | 230 V, 50/60 Hz, 7.5 A |
| Installation | Typically adjacent to or below compatible analyzer |
| Warranty | 90 days |
The PerkinElmer N5374099 Intracooler is primarily intended for subambient thermal analysis. Its most important application is extending the temperature range of compatible differential scanning calorimeters so researchers can investigate thermal transitions that occur below room temperature.
Typical DSC applications can include polymer characterization, glass-transition measurements, crystallization studies, melting-point and phase-transition analysis, pharmaceutical characterization, materials research, and evaluation of thermal properties across a broad temperature range.
Intracooler systems can also be used with certain compatible PerkinElmer thermomechanical and dynamic mechanical analysis instruments.
Because the N5374099 was engineered around specific PerkinElmer analyzer configurations, buyers should verify compatibility with their exact instrument and required mounting or connection hardware before purchase.
The PerkinElmer N5374099 is particularly relevant for materials-science laboratories, polymer research facilities, pharmaceutical laboratories, chemical R&D groups, quality-control departments, academic research laboratories, thermal analysis facilities, and industrial materials-testing environments.
It can be especially valuable for laboratories that routinely perform DSC experiments below room temperature but do not need the substantially lower temperatures or operating complexity associated with liquid-nitrogen cooling.
Laboratories already operating compatible legacy PerkinElmer thermal analyzers may also find a refurbished Intracooler useful for replacing an aging or failed cooling system while extending the service life of otherwise functional analytical equipment.
The N5374099 is designed specifically to provide subambient cooling for compatible PerkinElmer thermal analyzers.
It is important to distinguish between the temperature capability of the Intracooler hardware and the resulting operating range of the complete analytical system. PerkinElmer's Intracooler configurations were designed to extend compatible DSC and thermal analysis instruments to specific subambient operating temperatures.
With the appropriate Intracooler configuration and compatible analyzer, DSC operation can extend to approximately -65°C.
Actual minimum achievable temperature depends on the thermal analyzer, Intracooler configuration, ambient laboratory conditions, electrical supply, cooling interface, and condition of the complete system.
For that reason, laboratories should evaluate the N5374099 according to the requirements of the complete PerkinElmer thermal analysis system rather than treating it as a standalone general-purpose -65°C chiller.
The PerkinElmer Intracooler uses closed-loop mechanical refrigeration to continuously remove heat from the cooling interface connected to the thermal analyzer.
Unlike conventional laboratory recirculating chillers, where maximum pump flow and pressure are often primary selection criteria, the N5374099 was designed around the cooling requirements and interface of specific PerkinElmer analytical instruments.
The cooling system automatically circulates coolant through the appropriate chamber or cooling assembly to maintain the subambient conditions required by the analyzer.
This dedicated design is one reason instrument compatibility is more important than general pump specifications when selecting an Intracooler.
Buyers replacing an existing PerkinElmer cooling system should verify the analyzer model, existing connections, mounting hardware, and required accessories before purchase.
This used PerkinElmer N5374099 Intracooler is refurbished and tested by American Instrument Exchange before shipment. Our technicians inspect the refrigeration system, circulation components, electrical system, condenser, controls, coolant connections, and other accessible components for proper operation.
The Intracooler is operated for extended periods to evaluate refrigeration performance, circulation, temperature pull-down, and overall system stability.
Because the N5374099 is designed to operate as part of a PerkinElmer thermal analysis system, standalone testing cannot duplicate every analytical application or instrument configuration. If your laboratory has a specific analyzer or target operating condition, please provide that information before shipment.
When practical, American Instrument Exchange will incorporate customer-requested operating conditions into final testing.
A 90-day warranty is included with this refurbished PerkinElmer Intracooler.
The PerkinElmer N5374099 should be selected differently from a conventional recirculating chiller. The primary consideration is compatibility with the thermal analyzer rather than general cooling capacity, reservoir volume, or maximum pump flow.
PerkinElmer designed Intracoolers for specific DSC, TMA, and DMA systems. Laboratories should therefore confirm the exact analyzer model and required cooling interface before purchasing a replacement unit.
Temperature requirements are equally important. An Intracooler can provide convenient mechanical refrigeration for many routine subambient thermal-analysis experiments, avoiding the need for liquid nitrogen during procedures that remain within its operating capability.
Applications requiring substantially lower temperatures may require a different cooling configuration, while laboratories simply needing coolant for general analytical instruments should consider a conventional recirculating chiller instead.
American Instrument Exchange can help determine whether an available refurbished Intracooler or general-purpose laboratory chiller is the more appropriate solution based on your instrument and temperature requirements.
American Instrument Exchange stocks a range of laboratory circulators, including dedicated analytical instrument cooling systems, recirculating chillers, refrigerated circulators, and heated circulating baths. Laboratories using the PerkinElmer N5374099 may also want to compare available thermal analysis instruments, laboratory water baths, and other refurbished analytical and laboratory equipment.
The N5374099 is a specialized refrigeration system used to provide subambient cooling for compatible PerkinElmer differential scanning calorimeters and other thermal analysis instruments.
No. Although it uses refrigeration and circulating coolant, the N5374099 was designed specifically as an accessory for compatible PerkinElmer thermal analysis equipment.
PerkinElmer Intracoolers were designed for selected Pyris 1 DSC, Pyris 6 DSC, DSC 7, TMA 7, and DMA 7 systems. Exact compatibility and required hardware should be verified for the individual analyzer before purchase.
The achievable analytical operating temperature depends on the specific Intracooler and analyzer configuration. Compatible PerkinElmer systems equipped with the appropriate Intracooler configuration can support DSC operation to approximately -65°C.
For many routine subambient DSC applications within its temperature capability, an Intracooler can provide mechanical refrigeration without routine liquid-nitrogen cooling. Experiments requiring substantially lower temperatures may still require another cooling method.
The N5374099 was supplied as a PerkinElmer thermal analysis accessory and manufactured for PerkinElmer by PolyScience.
This American Instrument Exchange unit is configured for 230 V, 50/60 Hz electrical service and is rated at 7.5 A.
Yes. This used PerkinElmer N5374099 Intracooler is refurbished and tested by American Instrument Exchange and includes a 90-day warranty.
CLICK HERE to see the PerkinElmer Intracooler Chiller on our YouTube channel
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.