Plas-Labs 830-ABB.CLC HEPA-Filtered Glove Box
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Plas-Labs 830-ABB.CLC Glove Box is a negative-pressure laboratory containment enclosure equipped with a closed-loop HEPA filtration system. Designed for precision weighing, particulate containment, and handling appropriate hazardous or sensitive materials, this system provides a draft-free working environment while continuously circulating the chamber atmosphere through two HEPA filters.
Unlike a conventional laboratory glove box that relies primarily on a sealed enclosure, the Plas-Labs 830-ABB.CLC incorporates an enclosed blower, dual HEPA filters, and Magnehelic pressure gauges. These components help maintain negative-pressure conditions, capture airborne particulates, and allow operators to monitor chamber pressure and filter resistance.
The glove box features a transparent acrylic enclosure, two glove ports, and a vacuum-capable transfer chamber. Its spacious interior accommodates analytical balances, precision balances, moisture analyzers, sample preparation equipment, and other laboratory instruments requiring protection from drafts or controlled particulate handling.
The closed-loop filtration arrangement recirculates filtered air within the enclosure rather than relying on continuous exhaust to the surrounding laboratory. This distinguishes the CLC configuration from the manufacturer's open-exhaust models and makes understanding the intended application especially important.
This Plas-Labs 830-ABB.CLC is used and refurbished by American Instrument Exchange. AIE inspects and tests the chamber, filtration system, blower, gauges, seals, and other installed components before shipment. New gloves and a 90-day warranty are included.
Plas-Labs model 830-ABB.CLC
Negative-pressure laboratory glove box
Closed-loop, double-HEPA filtration system
Two cylindrical 8-inch-diameter HEPA filters
Enclosed recirculation blower
Two Magnehelic pressure gauges
Monitoring of chamber pressure and filter pressure drop
Non-hygroscopic prefilters
Clear acrylic enclosure with removable top
Two glove ports with new gloves included
Adjustable glove clamps
Separate cylindrical transfer chamber
Gas-purging valves
Pressure-relief valve
Hospital-grade electrical outlet strip
Draft-free working environment for precision weighing
Used and refurbished by American Instrument Exchange
90-day warranty included
Precision weighing and the handling of potentially hazardous powders present two different laboratory challenges.
Air currents can interfere with analytical balance readings, particularly when measuring small sample masses. At the same time, weighing or transferring certain powders can generate airborne particles that should remain contained within a controlled workspace.
The Plas-Labs 830-ABB.CLC addresses these challenges by combining a glove-access enclosure with negative-pressure operation and closed-loop HEPA filtration.
Researchers can handle samples through glove ports while minimizing direct exchange with the surrounding laboratory. The integrated blower continuously circulates the chamber atmosphere through HEPA filters, and pressure gauges provide a means of monitoring system conditions.
The result is a specialized glove box suitable for appropriately assessed weighing and particulate-handling applications.
The Plas-Labs 830-ABB.CLC can support analytical and microbalance weighing, pharmaceutical powder handling, materials science research, particulate sample preparation, asbestos-related analytical procedures, environmental sample analysis, polymer research, dry-weight measurements, moisture-content studies, and other applications requiring a draft-free enclosure with particulate filtration.
Its suitability for hazardous substances depends on the specific material, exposure risk, filtration performance, and laboratory containment requirements.
This system is particularly useful for analytical chemistry laboratories, pharmaceutical research facilities, environmental testing laboratories, materials science departments, industrial quality-control facilities, academic research institutions, and laboratories performing precision weighing or particulate-sensitive sample preparation.
It may also be useful for research involving potentially hazardous powders when the laboratory's risk assessment establishes that the enclosure and filtration configuration provide appropriate protection.
| Specification | Details |
|---|---|
| Manufacturer | Plas-Labs |
| Model | 830-ABB.CLC |
| AIE Inventory Number | 2739E |
| Equipment Type | Negative-Pressure HEPA-Filtered Glove Box |
| Filtration Configuration | Closed-Loop Recirculating |
| Main Filtration | Two Cylindrical HEPA Filters |
| HEPA Filter Diameter | 8" Each |
| Prefiltration | Non-Hygroscopic Prefilters |
| Air Circulation | Enclosed Blower |
| Pressure Monitoring | Two Magnehelic Gauges |
| Chamber Construction | 3/8" Clear Acrylic |
| Interior Dimensions, Manufacturer 830-ABB | 35"W × 29"D × 30"H |
| Exterior Dimensions, Manufacturer 830-ABB Base | 49"W × 30"D × 31"H |
| Additional CLC Filtration Height | Approximately 15.5" |
| Approx. Overall Height with CLC Package | 46.5" |
| Manufacturer Chamber Volume | 17.6 cu ft |
| Transfer Chamber | 12"L × 11" ID |
| Glove Access | Two Ports |
| Gloves | New Gloves Included |
| Gas-Purging Valves | Four |
| Electrical Outlet Strip | Hospital Grade |
| North American Electrical | 115–120 V, 60 Hz, Up to 12 A |
| Condition | Used / Refurbished |
| Warranty | 90 Days from American Instrument Exchange |
The most important distinguishing feature of the 830-ABB.CLC is its closed-loop filtration package.
An enclosed blower continuously circulates the internal chamber atmosphere through two cylindrical HEPA filters.
The filters capture airborne particulates passing through the filtration system, helping reduce particle concentrations within the enclosure.
Unlike an open-exhaust system, the CLC arrangement returns filtered air to the chamber.
This design provides continuous particulate filtration without requiring the entire circulating airflow to be exhausted through the building ventilation system.
However, recirculation does not remove all types of contaminants. HEPA filters capture particles, not gases or chemical vapors.
The CLC configuration is designed for negative-pressure operation.
Maintaining the chamber below surrounding room pressure helps reduce the tendency for airborne particulates to escape through minor leakage paths.
This is an important distinction from positive-pressure glove boxes, which are generally configured to protect sensitive products from contamination entering the enclosure.
Negative pressure can support containment, but the actual protection provided depends on enclosure integrity, airflow performance, filtration, glove condition, and appropriate testing.
The Model 830-ABB.CLC should not automatically be considered a certified pharmaceutical containment isolator or biosafety cabinet.
The CLC package includes two Magnehelic gauges.
One monitors chamber pressure, while the other measures pressure differential associated with the filtration system.
These readings help operators evaluate whether the enclosure is operating under the intended conditions and whether filter resistance is increasing.
As particulate loading increases, pressure drop across a filter may change.
Monitoring these gauges supports maintenance planning and provides useful information about system operation.
The filtration package includes two cylindrical HEPA filters, each approximately eight inches in diameter, together with non-hygroscopic prefilters.
The prefilters capture larger particles before they reach the main HEPA filtration stages.
This can help reduce unnecessary loading of the HEPA filters.
Filter replacement intervals depend on the materials handled, operating hours, particulate loading, and pressure readings.
The installed filters should be evaluated for condition and application suitability before use with hazardous materials.
Plas-Labs developed the 830 Series in part to improve the performance of analytical balances and microbalances.
Small air currents can cause instability in sensitive weighing instruments, making readings difficult to reproduce.
The enclosed glove box minimizes drafts from laboratory ventilation systems, doors, and nearby personnel movement.
This can help create a more stable weighing environment for small samples.
The manufacturer also recommends using a marble support block beneath sensitive balances to improve stability.
A marble block should be considered an optional accessory unless specifically included with the AIE unit.
The spacious working chamber can accommodate analytical balances, precision balances, and suitable moisture analyzers.
Glove-port access allows operators to introduce or manipulate samples while minimizing disturbance to the chamber atmosphere.
The enclosure may be particularly useful when both weighing stability and particulate containment are important.
Balance installation should account for instrument dimensions, electrical requirements, vibration isolation, and airflow from the internal recirculation system.
Certain pharmaceutical powders require precautions during weighing, transferring, or sample preparation.
The 830-ABB.CLC provides a negative-pressure enclosure with HEPA particulate filtration that may be suitable for appropriately assessed powder-handling tasks.
However, the presence of HEPA filtration alone does not establish a particular occupational exposure limit, containment performance level, or suitability for highly potent pharmaceutical compounds.
Applications involving hazardous drugs or potent active pharmaceutical ingredients should be evaluated against the laboratory's required containment performance and applicable regulations.
The 830 Series is also intended for analytical procedures involving environmental samples, polymers, adhesives, powders, and other materials.
The glove-box enclosure helps reduce external drafts and limits uncontrolled particle movement during sample preparation.
Its transfer chamber allows materials to be introduced without opening the entire enclosure.
The standard 830 Series incorporates a cylindrical transfer chamber measuring approximately 12 inches long with an 11-inch internal diameter.
The transfer chamber provides a controlled pathway for moving samples, containers, and small equipment into or out of the main enclosure.
Using the transfer chamber can reduce disturbance to the internal atmosphere compared with opening the main enclosure directly.
Operators should follow the appropriate transfer and pressure-equalization procedures for the installed configuration.
The chamber uses 3/8-inch-thick clear acrylic construction.
This provides excellent visibility of instruments, samples, and working surfaces.
The removable upper section also facilitates installation of larger instruments that may be difficult to pass through the transfer chamber.
The acrylic enclosure should be cleaned using materials compatible with the manufacturer's recommendations.
Chemical compatibility is particularly important because Plas-Labs specifically advises against using the 830 Series with aromatic hydrocarbons.
Two glove ports allow researchers to manipulate samples while remaining physically separated from the chamber interior.
The standard 830 Series uses ambidextrous Hypalon gloves with adjustable clamps.
The adjustable clamps help maintain a secure glove-to-port connection as components experience normal wear.
This particular AIE unit includes new gloves.
Glove compatibility should always be evaluated for the chemicals and materials being handled.
The standard 830 Series includes a small pressure-relief valve designed to reduce glove resistance caused by pressure differences.
This helps make the glove box more comfortable to operate while supporting pressure management.
The relief valve is not a substitute for proper pressure control, and the CLC system should be operated according to the manufacturer's instructions.
A hospital-grade electrical outlet strip allows compatible instruments to operate within the enclosure.
This can support analytical balances, small measurement instruments, and other laboratory devices.
Electrical equipment should be selected according to the intended materials and atmospheric conditions.
The enclosure should not be assumed suitable for flammable or explosive atmospheres.
The standard Plas-Labs 830-ABB is a compact acrylic glove box with glove access and a transfer chamber.
The 830-ABB.CLC adds the closed-loop filtration package.
This includes a blower, two cylindrical HEPA filters, prefilters, and two Magnehelic gauges.
The CLC configuration is therefore more appropriate for applications requiring recirculating particulate filtration and negative-pressure operation.
The added filtration assembly also increases the overall height of the system.
Plas-Labs offers both closed-loop and open-exhaust filtration configurations.
The closed-loop CLC system continuously filters and recirculates the chamber atmosphere.
Open-exhaust configurations move air through the enclosure and discharge it through an appropriate exhaust arrangement, potentially connected to facility ventilation.
This distinction matters when selecting equipment for materials that generate vapors or gases.
Because the CLC system recirculates air, it should not be selected as a general-purpose chemical fume hood.
The Plas-Labs 830-ABB.CLC and 850-NB serve different laboratory purposes.
The 830-ABB.CLC is a negative-pressure, HEPA-filtered enclosure designed for particulate containment and draft-free precision weighing.
The 850-NB is an inert-atmosphere nitrogen dry box equipped with a molecular-sieve drying train for reducing moisture.
The 850-NB is generally better aligned with protecting air- or moisture-sensitive materials, while the 830-ABB.CLC emphasizes particulate filtration and containment.
Neither should be substituted for the other without evaluating the actual application.
A conventional filtered balance enclosure often has an open front or partially open sash.
The 830-ABB.CLC provides glove-port access within a more completely enclosed working chamber.
This can reduce direct interaction between the operator and the chamber atmosphere.
However, a closed glove box is not automatically superior for every application. The appropriate system depends on required airflow, containment performance, ergonomic access, and the materials being handled.
HEPA filtration is designed to remove airborne particles.
It does not reliably remove chemical vapors, gases, or all hazardous contaminants.
The manufacturer identifies applications involving certain potentially hazardous materials but also specifically warns that the 830 Series is not recommended for aromatic hydrocarbons.
Laboratories should therefore evaluate chemical compatibility and containment requirements before using the system with hazardous substances.
For volatile chemicals, an appropriately designed and exhausted chemical fume hood may be necessary.
American Instrument Exchange inspects and tests used glove boxes before shipment.
For this Plas-Labs 830-ABB.CLC, AIE technicians inspect the acrylic enclosure, removable top, seals, glove ports, new gloves, transfer chamber, blower, HEPA filtration assemblies, prefilters, Magnehelic gauges, electrical components, and other installed features.
The chamber is visually inspected for cracks, damaged seals, and other conditions that could affect operation.
AIE also performs pressure-decay testing to evaluate chamber integrity.
The blower and filtration system are operated to assess basic function, and the unit is cleaned before shipment.
Customers requiring specific filter-integrity testing, containment verification, or application-specific certification should discuss those requirements with AIE before purchase.
The 830-ABB.CLC combines a draft-free weighing environment with negative-pressure operation and closed-loop HEPA filtration.
Its large transparent chamber provides room for analytical balances and other laboratory instruments, while glove-port access and a transfer chamber allow materials to be handled with reduced disturbance to the enclosure atmosphere.
The dual HEPA filtration system and Magnehelic gauges provide capabilities not found on a basic unfiltered glove box.
Purchasing a used and refurbished unit from American Instrument Exchange can provide substantial savings compared with acquiring a new system.
This unit includes new gloves and a 90-day warranty.
The manufacturer's standard 830-ABB enclosure measures approximately 49 inches wide × 30 inches deep × 31 inches high, including its transfer chamber.
The closed-loop filtration package adds approximately 15.5 inches to the height, producing an estimated overall height of 46.5 inches.
Before delivery, laboratories should confirm available bench or stand space, electrical service, doorway clearance, and access for filter maintenance.
The North American 830 Series is specified for 115–120 V, 60 Hz electrical service, with a maximum rating of 12 A.
The system should be inspected and its negative-pressure and filtration performance verified after installation, particularly before handling hazardous materials.
Laboratories using a Plas-Labs 830-ABB.CLC may also require analytical balances, precision balances, other glove boxes, biosafety cabinets, chemical fume hoods, and laboratory ovens.
American Instrument Exchange supplies used and refurbished laboratory glove boxes, containment enclosures, balances, fume hoods, biosafety cabinets, and other equipment for pharmaceutical, industrial, academic, and research laboratories.
The Plas-Labs 830-ABB.CLC is a negative-pressure glove box equipped with a closed-loop, double-HEPA filtration system for appropriate particulate-handling and precision weighing applications.
CLC refers to the manufacturer's closed-loop filtration configuration, which continuously circulates and filters the internal chamber atmosphere.
The standard CLC package includes two cylindrical HEPA filters, each approximately eight inches in diameter.
Yes. Two Magnehelic gauges monitor chamber pressure and pressure differential across the filtration system.
The standard CLC configuration recirculates filtered air within the enclosure. It is not the same as the manufacturer's open-exhaust configuration.
Yes. The 830 Series was developed to provide a draft-free environment for analytical balances, microbalances, and related weighing instruments.
Potentially, depending on the material and required containment performance. The installed system should be evaluated and qualified for the specific hazard before use.
No. HEPA filtration captures airborne particulates and should not be relied upon for chemical vapor removal.
No. Plas-Labs specifically advises against using the 830 Series with aromatic hydrocarbons.
Yes. The standard cylindrical transfer chamber measures approximately 12 inches long and 11 inches in internal diameter.
The manufacturer's standard 830-ABB enclosure measures 49"W × 30"D × 31"H. The CLC filtration package adds approximately 15.5 inches to the overall height.
Yes. American Instrument Exchange lists new gloves as included.
The 830-ABB.CLC emphasizes negative-pressure particulate containment and HEPA filtration. The 850-NB emphasizes inert gas and moisture removal using a molecular-sieve drying train.
No. The 830-ABB.CLC is a laboratory glove box and should not be assumed to meet Class II biosafety cabinet standards.
Yes. American Instrument Exchange includes a 90-day warranty.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.