Plas-Labs 856-HYPO Hypoxia Chamber Glove Box
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Plas-Labs 856-HYPO Hypoxia Chamber is an advanced controlled-atmosphere glove box designed for hypoxia research, physiological oxygen cell culture, tumor-cell studies, stem-cell research, and other biological applications requiring precise control of oxygen, carbon dioxide, and temperature. Unlike a conventional laboratory glove box used simply to isolate materials from room air, the 856-HYPO actively monitors and automatically controls the internal environment to create repeatable experimental conditions for oxygen-sensitive cell culture research.
The system provides an oxygen control range of 0–25%, a carbon dioxide range of 0–20%, and temperature control from ambient to 40°C. Dedicated O₂ and CO₂ sensors continuously monitor chamber conditions, while a platinum RTD measures temperature. A Peltier thermoelectric system provides temperature control without relying on a conventional compressor-based refrigeration system.
An 8-inch color touchscreen provides centralized control of the chamber environment. Password-protected PID controls allow researchers to establish experimental setpoints, while on-screen and Ethernet-based data logging help document environmental conditions during long-term studies.
The 856-HYPO also incorporates dedicated connections for nitrogen, carbon dioxide, oxygen, and inert gas, giving researchers substantial flexibility in establishing different controlled-atmosphere conditions.
A transparent transfer chamber allows cultures, media, consumables, and other materials to enter and leave the glove box while minimizing disruption of the primary chamber atmosphere. Glove-port access allows researchers to manipulate cells and samples without routinely exposing them to ambient laboratory oxygen.
This Plas-Labs 856-HYPO Hypoxia Chamber is used and refurbished by American Instrument Exchange. AIE technicians inspect and test the environmental controls, chamber integrity, transfer system, sensors, touchscreen, gas connections, and other installed functions before shipment. This unit includes new gloves and a 90-day warranty.
Plas-Labs model 856-HYPO
Controlled-atmosphere hypoxia glove box
Designed for tumor-cell, stem-cell, and tissue-culture research
Oxygen control from 0–25%
Oxygen accuracy approximately ±0.25%
Carbon dioxide control from 0–20%
CO₂ accuracy approximately ±0.2%
Temperature control from ambient to 40°C
Temperature accuracy approximately ±0.3°C
8-inch color touchscreen
Password-protected configurable PID control
O₂ and CO₂ sensors
Platinum RTD temperature sensor
Peltier thermoelectric temperature-control system
Nitrogen, CO₂, O₂, and inert-gas connections
One-touch on-screen data logging
Ethernet connection for data logging
Internal air-circulation fan
Transparent transfer chamber
Glove-port access for continuous controlled-atmosphere manipulation
New gloves included with this AIE unit
115–120 V, 60 Hz electrical configuration
Used and refurbished by American Instrument Exchange
90-day warranty included
Oxygen concentration is an important experimental variable in cell biology.
Although standard cell culture is frequently performed in incubators exposed to approximately atmospheric oxygen conditions, cells within living tissues often experience substantially different oxygen concentrations.
Cancer cells, stem cells, primary cells, and other biological systems may change their metabolism, signaling, gene expression, differentiation, proliferation, or stress responses when oxygen availability changes.
A conventional controlled-oxygen incubator can establish reduced oxygen while cultures remain inside the incubator.
The problem arises when cultures are removed for feeding, passaging, microscopy, sampling, or experimental manipulation.
The Plas-Labs 856-HYPO addresses this limitation by turning the controlled atmosphere into the actual working environment.
Researchers manipulate cultures through glove ports while oxygen, CO₂, and temperature remain controlled around the samples.
The Plas-Labs 856-HYPO is well suited to hypoxia research, physiological oxygen cell culture, tumor biology, cancer-cell research, stem-cell research, regenerative medicine, developmental biology, metabolic studies, tissue engineering, organoid research, spheroid culture, primary-cell research, ischemia studies, drug discovery, translational research, and other experiments where oxygen concentration can influence biological behavior.
The system can also support controlled-atmosphere experiments that require simultaneous regulation of oxygen, carbon dioxide, and temperature.
The 856-HYPO is particularly useful for cancer research laboratories, stem-cell laboratories, biotechnology companies, pharmaceutical R&D groups, academic research institutions, regenerative medicine programs, tissue-engineering laboratories, drug-discovery groups, translational research centers, and other laboratories investigating oxygen-sensitive biological systems.
It is especially valuable when maintaining controlled oxygen during active manipulation is important to experimental design.
| Specification | Details |
|---|---|
| Manufacturer | Plas-Labs |
| Model | 856-HYPO |
| AIE Inventory Number | 2739F |
| Equipment Type | Hypoxia / Controlled-Atmosphere Glove Box |
| Primary Application | Hypoxia & Physiological Oxygen Research |
| Oxygen Range | 0–25% |
| Oxygen Accuracy | Approx. ±0.25% |
| Carbon Dioxide Range | 0–20% |
| CO₂ Accuracy | Approx. ±0.2% |
| Temperature Range | Ambient to 40°C |
| Temperature Accuracy | Approx. ±0.3°C |
| Environmental Controller | Configurable PID |
| User Interface | 8" Color Touchscreen |
| O₂ Sensor | Included |
| CO₂ Sensor | Included |
| Temperature Sensor | Platinum RTD |
| Temperature Control | Thermoelectric / Peltier |
| Internal Circulation | Fan |
| Data Logging | On-Screen / Ethernet |
| Gas Connections | N₂, CO₂, O₂ & Inert Gas |
| Interior Dimensions | 41"W × 28"D × 26"H |
| Exterior Dimensions | 55"W × 35"D × 38"H |
| Transfer Chamber | Approx. 12"L × 11" ID |
| Glove Port Diameter | Approx. 8.75" |
| Electrical | 115–120 V, 60 Hz, 12 A |
| Gloves | New Gloves Included |
| Condition | Used / Refurbished |
| Warranty | 90 Days from American Instrument Exchange |
The defining feature of the 856-HYPO is its ability to automatically establish and maintain controlled oxygen concentrations.
Plas-Labs specifies an oxygen range from 0 to 25% with approximately ±0.25% accuracy.
This broad range allows researchers to investigate a variety of oxygen environments, from pronounced hypoxia through physiological oxygen concentrations and up to approximately atmospheric conditions.
Rather than manually purging the chamber and estimating the resulting oxygen level, the 856-HYPO uses an oxygen sensor and electronic control system to monitor and regulate the chamber atmosphere.
Hypoxia research does not always mean pushing oxygen concentration toward zero.
Many tissues in the human body naturally experience oxygen concentrations substantially below atmospheric levels.
Researchers may therefore establish moderate oxygen conditions intended to better represent the physiological environment experienced by cells in vivo.
These conditions are sometimes described as physiological oxygen or physoxia.
The 856-HYPO allows researchers to establish these intermediate oxygen concentrations while continuing to manipulate cultures within the same controlled atmosphere.
Reduced oxygen plays an important role in cellular signaling, metabolism, gene expression, angiogenesis, differentiation, stress responses, and disease progression.
The 856-HYPO allows researchers to expose cells to controlled hypoxic conditions and perform manipulations without routinely returning the cultures to atmospheric oxygen.
This can reduce an important uncontrolled variable in experiments where oxygen exposure itself affects cellular response.
The 856-HYPO provides independent CO₂ control from 0 to 20%, with manufacturer-specified accuracy of approximately ±0.2%.
CO₂ control is especially important for mammalian cell culture using bicarbonate-buffered media.
Maintaining the appropriate CO₂ environment helps support stable media pH while cultures remain inside the chamber.
Because the entire working environment is controlled, cultures can remain under the selected CO₂ conditions during many manipulations rather than being moved to an open laboratory bench.
Plas-Labs specifies a temperature range from ambient to 40°C with approximately ±0.3°C accuracy.
A platinum RTD provides temperature sensing.
Maintaining controlled temperature throughout the chamber allows cell culture manipulations to take place without the temperature changes associated with repeatedly transferring vessels between an incubator and room-temperature work surface.
The 856-HYPO uses a thermoelectric assembly based on Peltier technology.
A Peltier system moves heat electronically rather than using a conventional compressor-based refrigeration circuit.
This approach is well suited to a controlled glove-box environment because it allows precise temperature management within a compact system.
The actual achievable chamber temperature remains dependent on ambient conditions because the specified range begins at ambient temperature.
An 8-inch color touchscreen serves as the primary interface for environmental control.
Researchers can view chamber conditions, establish operating parameters, access control functions, and review logged information from one centralized display.
The touchscreen simplifies management of what would otherwise require separate oxygen, CO₂, and temperature controllers.
The 856-HYPO uses configurable proportional-integral-derivative, or PID, control.
PID control continuously compares measured chamber conditions with the selected setpoint and adjusts the system accordingly.
This allows the chamber to automatically maintain oxygen, carbon dioxide, and temperature rather than relying on repeated manual adjustments.
Administrator settings are password protected to help prevent unintended changes to experimental parameters.
The 856-HYPO incorporates on-screen data logging.
This allows researchers to monitor environmental conditions during an experiment and provides a record of chamber performance over time.
An Ethernet connection also supports external data-logging workflows.
For long-term hypoxia studies, documenting oxygen, CO₂, and temperature conditions can provide valuable context when reviewing experimental results.
Nitrogen is typically used to reduce oxygen concentration within the chamber.
Introducing nitrogen displaces oxygen-containing room air until the controller reaches the selected oxygen setpoint.
The oxygen sensor then provides feedback to the control system so the desired atmosphere can be maintained.
Gas supply, regulator pressure, tubing, and connections should be configured according to Plas-Labs requirements.
The system also provides a dedicated oxygen connection.
This gives researchers greater flexibility in controlling oxygen concentration and recovering from conditions below the desired setpoint.
The combination of nitrogen and oxygen connections allows the chamber controller to actively manage a broad oxygen range.
A dedicated CO₂ connection supplies the gas needed for controlled cell-culture conditions.
The CO₂ sensor provides feedback to the controller so the selected concentration can be maintained.
This capability distinguishes the 856-HYPO from basic low-oxygen glove boxes that simply purge the chamber with nitrogen without regulating the CO₂ environment required for mammalian cell culture.
In addition to the dedicated nitrogen, oxygen, and carbon dioxide connections, the chamber provides an inert-gas hookup.
This expands the system's flexibility for specialized controlled-atmosphere research.
The appropriate gas configuration depends on the experimental application and should follow manufacturer recommendations and laboratory safety procedures.
An internal circulation fan helps distribute the controlled atmosphere throughout the chamber.
Air circulation is important because localized pockets with different oxygen, CO₂, or temperature conditions could otherwise develop around equipment, culture vessels, or chamber surfaces.
Consistent circulation helps the sensors and control system maintain a more representative chamber environment.
The primary chamber measures approximately 41 inches wide × 28 inches deep × 26 inches high.
This provides a substantial workspace for culture vessels, racks, media, pipettes, small instruments, and other experimental materials.
The large chamber is especially useful when researchers need to perform complete workflows rather than simply incubate samples.
Equipment placement should preserve adequate internal air circulation and access to the glove ports.
Researchers access the chamber through approximately 8.75-inch glove ports.
Integrated gloves allow cells and samples to be manipulated without opening the chamber to ambient laboratory air.
This physical barrier is one of the principal advantages of a hypoxia glove box over a conventional controlled-oxygen incubator.
Routine procedures such as media changes, sampling, passaging, and preparation can potentially remain within the controlled atmosphere.
This AIE unit includes new gloves.
The 856-HYPO incorporates a transparent transfer chamber measuring approximately 12 inches long with an approximately 11-inch internal diameter.
The transfer chamber allows cultures, media, supplies, and other materials to enter or leave without opening the entire main chamber.
This helps minimize disruption to established oxygen, CO₂, and temperature conditions.
A vacuum gauge assists with monitoring transfer-chamber operation.
The transfer chamber incorporates a white leveling tray designed to help facilitate movement of liquids and culture materials.
This is particularly useful in cell-culture workflows where media bottles, culture vessels, and other liquid-containing items need to move between the laboratory and controlled chamber.
Appropriate transfer procedures should be established to minimize spills and atmospheric disturbance.
Tumor-cell biology is one of the principal applications identified by Plas-Labs for the 856-Series.
Solid tumors can contain regions with substantially reduced oxygen availability.
Researchers studying tumor metabolism, angiogenesis, invasion, therapeutic response, cell signaling, and other processes may therefore need to expose cultures to controlled hypoxic conditions.
The 856-HYPO allows those cultures to remain under the selected oxygen environment during both incubation and manipulation.
Plas-Labs also specifically identifies stem-cell research as an intended application.
Oxygen concentration can influence stem-cell maintenance, proliferation, differentiation, metabolism, and other biological responses.
A controlled hypoxia workstation allows researchers to investigate these processes while minimizing unintended exposure to atmospheric oxygen during routine handling.
Cancer research often involves studying how cells respond to reduced oxygen.
Hypoxia can affect gene expression, metabolism, angiogenic signaling, drug sensitivity, and other aspects of tumor biology.
By precisely controlling oxygen while also maintaining CO₂ and temperature, the 856-HYPO provides a platform for investigating these responses under defined environmental conditions.
Three-dimensional cell cultures such as organoids and spheroids can develop oxygen gradients that differ from conventional monolayer cultures.
Researchers investigating these models may benefit from controlling the oxygen concentration surrounding the culture.
The 856-HYPO also allows researchers to manipulate these cultures without automatically returning them to atmospheric oxygen.
Suitability depends on the specific experimental model and culture protocol.
Tissue engineering and regenerative medicine research frequently investigates how environmental conditions influence cell growth, differentiation, extracellular matrix formation, and tissue development.
Controlled oxygen can be an important variable in these experiments.
The 856-HYPO provides a workspace in which researchers can maintain selected oxygen, CO₂, and temperature conditions throughout multiple experimental steps.
Drug response can vary with cellular oxygen conditions.
A compound tested exclusively under atmospheric oxygen may produce different responses when cells are cultured under physiologically relevant or hypoxic conditions.
The 856-HYPO allows researchers to incorporate oxygen concentration as a controlled experimental variable during drug-screening and translational studies.
A standard CO₂ incubator primarily controls temperature, humidity, and carbon dioxide while cultures remain inside the cabinet.
Once cultures are removed, they are exposed to room conditions.
The 856-HYPO controls the entire working chamber.
Researchers can therefore manipulate cultures through glove ports while oxygen, CO₂, and temperature remain controlled around the samples.
This is especially important when transient oxygen exposure could affect experimental results.
A tri-gas incubator adds oxygen control to conventional CO₂ incubation.
For experiments that only require controlled oxygen during incubation, a tri-gas incubator may be sufficient.
The 856-HYPO becomes particularly useful when researchers need to feed, passage, sample, observe, or otherwise manipulate cultures without leaving the controlled atmosphere.
The appropriate choice depends on how much of the experimental workflow needs to remain under controlled oxygen.
The Plas-Labs hypoxia and anaerobic systems should not be treated as interchangeable.
An anaerobic chamber is designed to establish extremely low oxygen conditions for oxygen-sensitive organisms or materials and may incorporate catalyst systems specifically intended to remove trace oxygen.
The 856-HYPO is designed to precisely regulate oxygen across a broad 0–25% range while simultaneously controlling CO₂ and temperature for hypoxia and cell-culture research.
This makes it much better suited to experiments requiring defined intermediate oxygen concentrations.
A nitrogen dry box typically uses nitrogen purging to reduce oxygen and moisture for materials handling, electronics, chemical research, or storage.
The 856-HYPO is fundamentally different.
It actively measures and controls oxygen, CO₂, and temperature and is specifically designed around biological research.
Researchers looking for controlled physiological cell-culture conditions should therefore distinguish a true hypoxia workstation from a basic nitrogen-purged glove box.
A general isolation glove box provides a physical barrier between the operator, sample, and surrounding laboratory.
The 856-HYPO adds active environmental control.
Sensors continuously measure chamber conditions while the PID controller manages gases and temperature to maintain selected experimental parameters.
This makes it an environmental research platform rather than simply a sealed enclosure.
The Plas-Labs 856-HYPO is not a Class II biological safety cabinet.
A biosafety cabinet uses defined HEPA-filtered airflow patterns to provide personnel, environmental, and product protection for appropriate biological procedures.
The 856-HYPO is primarily designed to create a controlled oxygen, CO₂, and temperature environment for research.
Its enclosed glove-box format should not be assumed to provide biosafety-cabinet-level containment for infectious aerosols or other biological hazards.
Appropriate biological risk assessment and containment equipment should be used when hazardous biological materials are involved.
The standard 856-HYPO should also be distinguished from Plas-Labs glove boxes specifically designed around HEPA-filtered containment.
The core 856-Series specifications emphasize environmental gas and temperature control rather than HEPA-filtered hazardous-particle containment.
It should therefore not automatically be selected for toxic powders, hazardous aerosols, or other applications requiring validated HEPA containment.
The primary value of the 856-HYPO is precise environmental control for hypoxia research.
The standard 856-HYPO specifications center on oxygen, CO₂, and temperature.
Humidity control should not be assumed unless the individual unit has a compatible optional humidity-control system installed.
Researchers performing extended cell-culture procedures should consider evaporation, culture-vessel design, and their specific humidity requirements when planning experiments.
A hypoxia workstation becomes especially valuable when oxygen exposure during manipulation matters to the experiment.
If cultures only need reduced oxygen during incubation, a tri-gas incubator may provide a simpler solution.
If cells need to remain at a defined oxygen concentration while they are fed, passaged, sampled, observed, or prepared for downstream analysis, a glove-box workstation such as the 856-HYPO provides much greater workflow control.
The system's 0–25% oxygen range also allows one workstation to support multiple experimental oxygen conditions.
American Instrument Exchange inspects and tests used hypoxia glove boxes before shipment.
For this Plas-Labs 856-HYPO, AIE technicians inspect the chamber, glove ports, new gloves, seals, transfer chamber, vacuum gauge, touchscreen, environmental controller, oxygen sensor, CO₂ sensor, platinum RTD, circulation fan, Peltier temperature-control system, gas connections, Ethernet interface, electrical components, and other installed functions.
The enclosure is visually inspected for cracks, damaged seals, and other conditions that could affect chamber integrity.
AIE also performs pressure-decay testing by pressurizing the chamber and monitoring whether it maintains pressure appropriately.
Environmental controls are operated to verify proper response and performance.
Accessible interior and exterior surfaces are thoroughly cleaned before shipment.
Hypoxia workstations are sophisticated controlled-environment systems, and purchasing a used and refurbished unit can significantly reduce the cost of adding physiological oxygen research capability to a laboratory.
The Plas-Labs 856-HYPO combines oxygen control, CO₂ control, temperature regulation, glove-port access, controlled material transfer, touchscreen operation, PID control, and data logging in one integrated system.
For cancer biology, stem-cell research, tissue engineering, organoid research, drug discovery, and other oxygen-sensitive applications, this provides substantially greater environmental control than a conventional incubator or basic glove box.
American Instrument Exchange inspects, tests, and cleans this system before shipment and includes new gloves and a 90-day warranty.
The Plas-Labs 856-HYPO measures approximately 55 inches wide × 35 inches deep × 38 inches high, including its 12-inch-long transfer chamber.
The internal chamber measures approximately 41 inches wide × 28 inches deep × 26 inches high.
The North American configuration requires 115–120 V, 60 Hz electrical service and is rated at approximately 12 A.
Before delivery, laboratories should confirm available bench or stand space, doorway clearance, electrical service, gas supplies, regulator requirements, ventilation considerations, and access around the transfer chamber.
Nitrogen, CO₂, O₂, and any other required gases should be supplied using appropriate regulators and laboratory gas-handling practices.
After installation, environmental controls and chamber integrity should be evaluated before critical experiments are begun.
Laboratories using a Plas-Labs 856-HYPO Hypoxia Chamber may also require CO₂ incubators, tri-gas incubators, biosafety cabinets, inverted microscopes, centrifuges, laboratory refrigerators, laboratory freezers, ultra-low freezers, cryogenic storage systems, water baths, shakers, and other equipment supporting mammalian cell culture and biological research.
American Instrument Exchange supplies used and refurbished hypoxia chambers, glove boxes, incubators, biosafety cabinets, cold-storage equipment, centrifuges, and other laboratory equipment for biotechnology, pharmaceutical, academic, medical, and research laboratories.
The Plas-Labs 856-HYPO is a controlled-atmosphere glove box designed to automatically regulate oxygen, carbon dioxide, and temperature for hypoxia and physiological oxygen research.
Plas-Labs specifies an oxygen control range of 0–25%.
The manufacturer specifies oxygen accuracy of approximately ±0.25%.
The 856-HYPO provides CO₂ control from 0–20%.
Plas-Labs specifies approximately ±0.2% CO₂ accuracy.
The chamber controls temperature from ambient to approximately 40°C.
The manufacturer specifies approximately ±0.3°C temperature accuracy.
The system uses a platinum RTD temperature sensor with a sealing gland.
It uses a thermoelectric Peltier assembly.
Yes. The 856-HYPO uses an 8-inch color touchscreen for monitoring and controlling chamber conditions.
Yes. The environmental control system uses configurable PID control with password-protected administrator settings.
Yes. It provides one-touch on-screen data logging and an Ethernet connection for external data-logging applications.
The chamber provides dedicated connections for nitrogen, carbon dioxide, oxygen, and inert gas.
Yes. An air-circulation fan helps distribute the controlled atmosphere throughout the chamber.
The chamber measures approximately 41"W × 28"D × 26"H.
The complete system measures approximately 55"W × 35"D × 38"H, including the transfer chamber.
Yes. It incorporates a transparent transfer chamber approximately 12 inches long with an 11-inch internal diameter.
It allows cultures, media, supplies, and other materials to enter and leave while minimizing disruption to the controlled atmosphere in the main chamber.
Yes. Plas-Labs specifically identifies tumor-cell and cancer-cell research as intended applications.
Yes. Stem-cell research is another principal application identified by Plas-Labs.
Yes. Its broad oxygen range allows researchers to establish moderate physiological oxygen conditions as well as more pronounced hypoxia.
Yes. Integrated glove ports allow researchers to work with cultures while they remain inside the controlled chamber atmosphere.
A tri-gas incubator maintains controlled oxygen while cultures are inside the incubator. The 856-HYPO also provides a working chamber where researchers can manipulate cultures without routinely returning them to ambient laboratory conditions.
No. It is primarily a hypoxia and physiological oxygen workstation designed to regulate oxygen across a broad 0–25% range while also controlling CO₂ and temperature.
No. A nitrogen dry box primarily reduces oxygen and moisture through gas purging. The 856-HYPO actively senses and controls oxygen, CO₂, and temperature for biological research.
HEPA filtration is not listed as a standard feature of the manufacturer's 856-Series hypoxia chamber. HEPA capability should not be assumed unless an optional system is specifically installed on the individual unit.
Humidity control is not part of the standard 856-Series specifications. Any optional humidity-control equipment should be verified on the individual system.
No. It is a controlled-atmosphere hypoxia glove box and should not be substituted for a Class II biosafety cabinet when appropriate biological containment is required.
The North American 856-Series configuration requires 115–120 V, 60 Hz electrical service and is rated at approximately 12 A.
Yes. American Instrument Exchange lists this particular unit with new gloves.
Yes. This unit is used and refurbished by American Instrument Exchange.
AIE technicians inspect and test the chamber, seals, transfer system, environmental controller, touchscreen, O₂ and CO₂ sensors, temperature-control system, circulation fan, gas connections, and other installed functions. AIE also performs a pressure-decay test to evaluate chamber integrity.
Yes. American Instrument Exchange includes a 90-day warranty with this refurbished Plas-Labs 856-HYPO.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.