PolyScience 58809TD9A25R1 High-Capacity Recirculating Chiller

The PolyScience 58809TD9A25R1 is a 1.5 HP high-capacity recirculating chiller designed to provide continuous heat removal and temperature-controlled fluid circulation for demanding laboratory, analytical, and industrial equipment. With a 5°C to 35°C operating range and a high-flow turbine pump capable of circulating up to 11 GPM (41.6 L/min), this chiller is well suited for applications requiring substantial coolant flow and reliable continuous cooling.

Available used and refurbished from American Instrument Exchange, the PolyScience 58809TD9A25R1 combines refrigeration, a 13.25 L reservoir, digital monitoring, and high-volume fluid circulation in a self-contained system. It is particularly useful for cooling lasers, electron microscopes, analytical instruments, and other heat-generating equipment where a dedicated recirculating cooling system is preferable to facility water. A 90-day warranty is included.

Key Features

  • 1.5 HP high-capacity recirculating chiller

  • 5°C to 35°C operating temperature range

  • High-flow turbine pump

  • Maximum circulation flow rate of 11 GPM (41.6 L/min)

  • 13.25 L / 3.5 gal reservoir capacity

  • ±0.5°C temperature stability

  • Dual displays for temperature and pressure or flow monitoring

  • User-adjustable operating alarms

  • Designed for continuous external equipment cooling

  • Used, refurbished, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The PolyScience 58809TD9A25R1 is a refrigerated recirculating chiller designed to continuously remove heat from externally connected laboratory and process equipment. Rather than sending facility water through an instrument and then to drain, the chiller cools and recirculates a controlled volume of fluid through a closed cooling loop.

This particular model is configured for relatively high coolant flow. Its turbine pump can circulate up to 11 GPM, making the 58809TD9A25R1 particularly useful for applications with substantial coolant-volume requirements.

The integrated control system provides separate displays for temperature and pressure or flow information, allowing operators to monitor important cooling-system conditions during operation. User-adjustable alarms provide additional protection by alerting operators when operating conditions move outside selected parameters.

With its combination of substantial circulation capacity and a relatively compact footprint, the 58809TD9A25R1 can provide a dedicated cooling solution without requiring an unusually large amount of laboratory floor space.

Key Specifications

Specification Details
Manufacturer PolyScience
Model 58809TD9A25R1
Equipment Type High-capacity recirculating chiller
Chiller Rating 1.5 HP
Temperature Range 5°C to 35°C
Temperature Stability ±0.5°C
Pump Type Turbine pump
Maximum Flow Rate 11 GPM / 41.6 L/min
Reservoir Capacity 3.5 gal / 13.25 L
Display Dual temperature and pressure/flow displays
Alarms User-adjustable
Exterior Dimensions 19 in. W × 30.5 in. D × 26 in. H
Electrical Requirements 430 V, 60 Hz, 17.7 A, 3-phase
Application Type External equipment/process cooling
Warranty 90 days

Common Applications

The PolyScience 58809TD9A25R1 is suitable for laboratory and process equipment that generates substantial heat and requires a continuous supply of circulating coolant. Applications can include lasers, electron microscopes, analytical instrumentation, process equipment, condensers, vacuum systems, and other temperature-sensitive equipment.

Its high-flow turbine pump makes this model particularly appropriate for applications where moving a relatively large volume of coolant is more important than generating very high circulation pressure.

A recirculating chiller can also provide an alternative to once-through facility-water cooling in compatible applications. By continuously cooling and reusing the same heat-transfer fluid, laboratories can reduce water consumption while maintaining more consistent coolant conditions.

Ideal Laboratory Types

The PolyScience 58809TD9A25R1 is well suited for analytical laboratories, materials-science facilities, physics and optics laboratories, industrial research environments, pharmaceutical facilities, electronics research groups, quality-control laboratories, academic research facilities, and other laboratories operating heat-generating instrumentation.

The combination of a high circulation rate and dedicated refrigeration makes this model particularly attractive for laboratories running equipment continuously or managing larger thermal loads.

Temperature Control & Stability

The PolyScience 58809TD9A25R1 provides an operating temperature range from 5°C to 35°C with specified temperature stability of approximately ±0.5°C.

Unlike refrigerated circulators designed to reach very low subzero temperatures, this model is optimized for equipment and process cooling within a narrower range around typical laboratory temperatures. For many instrument-cooling applications, the objective is not to achieve extremely low temperatures but to continuously remove heat while maintaining a consistent coolant supply temperature.

Actual performance will depend on the thermal load generated by the connected equipment, ambient conditions, coolant selection, circulation rate, and installation. Buyers should compare the heat generated by their equipment with the chiller's available cooling performance at their intended operating temperature.

Circulation & Pump Performance

The turbine pump is one of the most important features of the PolyScience 58809TD9A25R1. It provides a maximum circulation flow rate of approximately 11 GPM, equivalent to 41.6 L/min.

This relatively high flow rate makes the chiller useful for equipment requiring substantial coolant movement through a comparatively unrestricted circulation loop. It also distinguishes the unit from positive-displacement chillers, which generally emphasize higher pressure at lower maximum flow rates.

Actual flow through connected equipment will depend on tubing diameter and length, fittings, coolant viscosity, elevation changes, operating temperature, and hydraulic restrictions within the external system.

When selecting a chiller, buyers should therefore consider both flow and pressure requirements rather than assuming that maximum flow alone determines compatibility.

Refurbishment & Testing

This used PolyScience 58809TD9A25R1 Recirculating Chiller is refurbished and tested by American Instrument Exchange before shipment. Our technicians inspect the refrigeration system, circulation pump, reservoir, temperature controller, displays, alarms, electrical components, and fluid connections and operate the system to confirm proper functionality.

Temperature-controlled equipment is tested using NIST-traceable probes and data loggers. Pump operation and fluid circulation are evaluated, while the refrigeration system is operated to verify appropriate cooling and temperature control. The reservoir and fluid-contact areas are also cleaned and inspected prior to shipment.

If your application requires operation at a particular coolant temperature or has specific testing requirements, contact American Instrument Exchange before shipment. When practical, our technicians can incorporate customer-requested conditions into final testing.

A 90-day warranty is included with this refurbished PolyScience recirculating chiller.

Choosing the Right Recirculating Chiller

Selecting the correct recirculating chiller requires matching the system to both the thermal and hydraulic requirements of the equipment being cooled. Important factors include required coolant temperature, cooling capacity, flow rate, pump pressure, reservoir volume, electrical service, and the resistance of the external circulation loop.

The PolyScience 58809TD9A25R1 is particularly well suited for applications requiring high coolant flow within a 5°C to 35°C operating range. Its 11 GPM turbine pump provides considerably more circulation volume than many smaller laboratory chillers.

Electrical requirements are especially important with this unit. The 58809TD9A25R1 requires 430 V, 60 Hz, 17.7 A, three-phase electrical service, so laboratories should verify that appropriate power is available before purchasing or installing the chiller.

Applications requiring substantially lower temperatures, very tight temperature stability, or high-pressure circulation through highly restrictive equipment may be better served by a different circulator configuration.

American Instrument Exchange can help compare available used and refurbished recirculating chillers based on your equipment's target temperature, thermal load, circulation requirements, and available electrical service.

Related Equipment

American Instrument Exchange stocks a variety of laboratory circulators, including high-capacity recirculating chillers, refrigerated circulators, heated circulators, and process temperature-control systems. Laboratories using this PolyScience chiller may also require laboratory water baths, reactors and fermenters, evaporators and extractors, or other refurbished laboratory equipment.

PolyScience 58809TD9A25R1 Frequently Asked Questions

What is the temperature range of the PolyScience 58809TD9A25R1?

The PolyScience 58809TD9A25R1 has an operating temperature range of 5°C to 35°C, making it suitable for a variety of laboratory instrument and process-cooling applications.

What is the maximum flow rate of this PolyScience chiller?

The turbine pump provides a maximum flow rate of approximately 11 GPM, or 41.6 L/min. Actual flow through connected equipment depends on the hydraulic resistance of the complete circulation loop.

What is a turbine-pump recirculating chiller?

A turbine-pump chiller is designed to provide relatively high coolant flow for external equipment and process cooling. It can be particularly useful when substantial fluid circulation is required through a comparatively unrestricted cooling loop.

What types of equipment can the PolyScience 58809TD9A25R1 cool?

Potential applications include lasers, electron microscopes, analytical instruments, process equipment, condensers, vacuum systems, and other heat-generating equipment with compatible cooling requirements.

Can this PolyScience chiller replace facility-water cooling?

In compatible applications, yes. A recirculating chiller continuously cools and reuses its heat-transfer fluid rather than sending facility water through an instrument and then to drain. This can reduce water consumption while providing more consistent coolant conditions.

What electrical service does the PolyScience 58809TD9A25R1 require?

This unit requires 430 V, 60 Hz, 17.7 A, three-phase electrical service. Buyers should verify electrical compatibility before purchasing and arrange installation by qualified personnel as appropriate.

Is this PolyScience chiller appropriate for very low-temperature applications?

No. Its specified operating range begins at 5°C. Laboratories requiring subzero coolant temperatures should select a refrigerated circulator or chiller designed for lower-temperature operation.

Does this refurbished PolyScience chiller include a warranty?

Yes. This used PolyScience 58809TD9A25R1 is refurbished and tested by American Instrument Exchange and includes a 90-day warranty.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.