Sartorius Secura 124-1S Analytical Balance

Fully Tested & Warrantied*
Brand : Sartorius
Product Code : SKU 0704J BALANCE
Sold Out
⚠

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Sartorius Secura 124-1S Analytical Balance – Used & Refurbished

The Sartorius Secura 124-1S Analytical Balance is a high-performance laboratory weighing instrument designed for precise quantitative measurements, reliable documentation, and enhanced protection against common weighing errors. With a maximum capacity of 120 g, 0.1 mg readability, and advanced safety features including isoCAL automatic internal adjustment, SQmin minimum-weight monitoring, and electronic leveling assistance, the Secura 124-1S is particularly well suited for pharmaceutical, biotechnology, chemical, and quality-control laboratories.

Available used and refurbished from American Instrument Exchange, the Sartorius SECURA124-1S combines analytical weighing performance with a color touchscreen, enclosed draft shield, USB connectivity, GLP/GMP documentation capabilities, and integrated weighing applications.

Each refurbished unit is inspected, calibrated, performance tested, and cleaned by American Instrument Exchange and includes a 90-day warranty.

Key Features

  • 120 g maximum weighing capacity

  • 0.1 mg / 0.0001 g readability

  • 0.1 mg repeatability specification

  • ±0.2 mg linearity limit

  • Single-range analytical weighing

  • isoCAL automatic internal adjustment

  • SQmin minimum sample weight monitoring

  • Real-Time Level Support with electronic leveling alerts

  • Color touchscreen interface

  • Enclosed glass draft shield

  • 90 mm diameter weighing pan

  • Approximately 209 mm weighing chamber height

  • USB-Direct connectivity

  • GLP/GMP-oriented documentation functions

  • Password protection and configurable safety settings

  • Below-balance weighing capability

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Sartorius Secura 124-1S belongs to the Secura family of analytical balances, developed to combine accurate mass determination with features that help laboratories prevent weighing errors before they affect analytical results.

The balance provides 120 g maximum capacity with 0.1 mg readability throughout its weighing range.

Unlike basic analytical balances that primarily display mass, the Secura platform incorporates functions designed to monitor instrument readiness, adjustment status, minimum sample weight, and operating conditions.

These capabilities are particularly useful in laboratories where weighing results must be reproducible, documented, and consistent with established quality procedures.

Common Applications

The Sartorius Secura 124-1S is suitable for pharmaceutical quality control, analytical chemistry, reference standards preparation, biotechnology research, chemical formulation, gravimetric analysis, quantitative sample preparation, environmental testing, and laboratory research.

Pharmaceutical laboratories can use the balance to prepare analytical standards, weigh formulation ingredients, and measure samples for quality-control procedures.

Biotechnology laboratories can use it for reagents, compounds, powders, and other research materials requiring four-decimal-place analytical resolution.

Chemical and environmental laboratories can use the Secura 124-1S for quantitative sample preparation and gravimetric procedures where accurate, repeatable mass determination is essential.

Ideal Laboratory Types

The Secura 124-1S is particularly well suited for pharmaceutical manufacturers, biotechnology companies, analytical testing laboratories, contract research organizations, chemical laboratories, quality-control departments, universities, and environmental testing facilities.

Its integrated safety functions make it especially attractive to laboratories that need more than basic analytical weighing but do not require the additional sensitivity of a semi-microbalance.

Analytical Weighing Performance

The Sartorius Secura 124-1S provides 120 g capacity with 0.1 mg readability.

Manufacturer specifications identify repeatability of 0.1 mg and a linearity limit of ±0.2 mg.

This performance places the instrument within the conventional four-decimal-place analytical balance category.

The single-range configuration provides consistent 0.1 mg readability throughout the full 120 g capacity, eliminating the need to switch between different readability ranges.

For laboratories routinely weighing small samples, reference materials, and analytical reagents, this combination provides a practical balance between sensitivity, capacity, and operating convenience.

Minimum Sample Weight & USP Applications

Minimum sample weight is an important consideration when using an analytical balance for pharmaceutical or other quantitative applications.

Although the Secura 124-1S displays measurements in 0.1 mg increments, readability alone does not establish the smallest sample that can be weighed with acceptable uncertainty.

Manufacturer literature for the Secura 124 analytical platform has identified a typical USP minimum weight of approximately 120 mg, although the actual minimum sample weight depends on repeatability and the laboratory's operating conditions.

Laboratories should determine their applicable minimum sample weight through appropriate performance testing and documented procedures rather than relying exclusively on a published typical value.

SQmin Minimum Weight Monitoring

One of the distinguishing features of the Secura 124-1S is Sartorius SQmin technology.

SQmin allows a laboratory to establish a minimum permissible sample weight based on its weighing requirements.

When properly configured, the balance can alert users when the sample mass falls below the established minimum.

This provides an additional safeguard against recording results that do not meet the laboratory's defined minimum-weight criteria.

SQmin is particularly valuable in pharmaceutical quality control, analytical testing, and other applications where minimum sample weight is incorporated into standard operating procedures.

isoCAL Automatic Internal Adjustment

The Sartorius Secura 124-1S incorporates isoCAL automatic internal adjustment.

The system uses an internal reference weight to adjust the balance when specified environmental or operating conditions are met.

For the Secura 124 analytical platform, automatic adjustment can be triggered by temperature changes of approximately 1.5 K or an elapsed interval of approximately four hours, depending on configuration.

Automatic adjustment helps compensate for environmental changes that could otherwise affect measurement accuracy.

External verification using appropriate certified reference weights should still be performed according to laboratory quality procedures.

Real-Time Level Support

Correct leveling is essential for reliable analytical weighing.

The Secura 124-1S incorporates electronic leveling assistance designed to notify the operator when the instrument is not properly leveled.

This feature is especially useful after cleaning, relocation, or adjustment of the balance's installation surface.

Leveling alerts help reduce the possibility of performing sensitive measurements while the balance is improperly positioned.

Controlling Drafts, Vibration & Static

At 0.1 mg readability, environmental conditions can significantly influence weighing performance.

Air movement from HVAC systems, open doors, and nearby personnel can create unstable readings.

Vibration from centrifuges, shakers, pumps, compressors, and unstable laboratory benches can also interfere with sensitive measurements.

Static electricity may affect powders, filters, plastic containers, and other insulating materials.

The Secura 124-1S incorporates an enclosed draft shield to reduce the influence of air movement.

For best results, the balance should be installed on a stable, level weighing surface away from vibration and direct airflow.

Color Touchscreen & Guided Operation

The Secura 124-1S uses a color touchscreen designed to simplify laboratory weighing procedures.

The interface provides access to weighing applications, operating settings, adjustment functions, and instrument information.

Clear visual prompts help users recognize operating conditions requiring attention.

For laboratories with multiple operators, the touchscreen can simplify training and promote more consistent use of weighing procedures.

GLP/GMP Documentation & Data Integrity

The Secura platform was designed with documentation and quality-assurance requirements in mind.

The balance supports GLP/GMP-oriented records, calibration and adjustment information, and electronic transfer of weighing results.

Password protection and configurable safety settings provide additional control over instrument operation.

These features can help laboratories maintain more consistent weighing procedures and reduce the risk of undocumented changes to important settings.

Regulatory compliance ultimately depends on the complete laboratory workflow, software configuration, validation, and operating procedures rather than the balance alone.

USB-Direct Connectivity

The Sartorius Secura 124-1S includes a USB interface with USB-Direct functionality.

This allows weighing results to be transferred to a compatible computer without requiring specialized additional software for basic data transfer.

Electronic transfer can reduce manual transcription and simplify the creation of laboratory records.

For laboratories performing repeated analytical procedures, this can improve workflow efficiency and reduce opportunities for recording errors.

Key Specifications

Specification Sartorius Secura 124-1S
Manufacturer Sartorius
Model SECURA124-1S
Balance Type Analytical Balance
Weighing Range Single Range
Maximum Capacity 120 g
Readability 0.1 mg / 0.0001 g
Repeatability Specification 0.1 mg
Linearity Limit ±0.2 mg
Internal Adjustment Yes, isoCAL
isoCAL Temperature Trigger Approx. 1.5 K
isoCAL Time Trigger Approx. 4 Hours
Recommended External Test Weight 100 g, E2 Class
Weighing Pan Diameter 90 mm
Weighing Chamber Height Approx. 209 mm
Draft Shield Enclosed Glass
Display Color Touchscreen
Minimum Weight Monitoring SQmin
Leveling Assistance Real-Time Level Support
Data Interface USB
Below-Balance Weighing Yes
Overall Dimensions Approx. 216 mm W × 360 mm D × 320 mm H
Operating Temperature 10–30°C
Power Supply AC Adapter, 100–240 VAC, 50/60 Hz
Condition Used & Refurbished
Warranty 90 Days from American Instrument Exchange

Secura 124-1S vs. Secura 224-1S

The Secura 124-1S and Secura 224-1S are both single-range analytical balances with 0.1 mg readability.

The primary difference is maximum capacity.

The Secura 124-1S provides 120 g capacity, while the Secura 224-1S increases capacity to 220 g.

Both models incorporate the Secura platform's advanced safety and adjustment features.

The 124-1S is an excellent choice for laboratories whose samples and weighing vessels remain comfortably within 120 g. The 224-1S is preferable when heavier containers or samples are routinely used.

Secura 124-1S vs. Secura 125-1S

The Secura 124-1S is a conventional analytical balance with 0.1 mg readability.

The Secura 125-1S is a semi-microbalance offering 0.01 mg readability, ten times finer than the 124-1S.

Both have 120 g maximum capacity, but the 125-1S is intended for applications requiring greater sensitivity and lower practical minimum sample weights.

The Secura 124-1S is generally more appropriate for routine analytical weighing where 0.1 mg resolution is sufficient.

Secura vs. Quintix Analytical Balances

The Sartorius Secura and Quintix families share many analytical weighing capabilities, including touchscreen operation and automatic internal adjustment on applicable models.

The Secura series adds an expanded collection of safety-oriented functions, including SQmin minimum-weight monitoring and advanced leveling assistance.

For laboratories primarily interested in routine analytical weighing, a Quintix balance may provide adequate functionality.

For laboratories emphasizing error prevention, documented procedures, and minimum-weight control, the Secura platform offers additional advantages.

Refurbishment & Performance Testing

Each used Sartorius Secura 124-1S offered by American Instrument Exchange undergoes inspection, cleaning, calibration, and functional testing before shipment.

Technicians inspect the housing, touchscreen, draft shield, weighing pan, leveling components, power supply, and installed accessories.

Weighing performance is evaluated with appropriate reference weights at multiple points across the 120 g capacity.

Repeatability testing uses repeated measurements of the same reference load to evaluate consistency.

Linearity testing checks performance at different loads, while corner-load testing evaluates the effect of sample placement on weighing results.

The internal isoCAL system, zero and tare functions, touchscreen controls, and applicable safety features are also checked.

Following final inspection and cleaning, the balance is prepared for shipment.

Refurbished equipment from American Instrument Exchange includes a 90-day warranty unless otherwise specified.

Shipping & Installation Considerations

The Secura 124-1S should be installed on a rigid, level, vibration-resistant weighing surface.

Direct airflow from HVAC outlets, fans, doors, and other sources should be minimized.

After shipment, the balance should be allowed to acclimate to the laboratory environment before critical measurements begin.

The leveling system should be checked, internal adjustment performed as appropriate, and weighing performance verified with suitable reference weights.

For demanding analytical measurements, operators should also consider sample temperature, static electricity, and vibration.

Related Laboratory Equipment

American Instrument Exchange maintains an extensive inventory of used and refurbished laboratory balances, including analytical balances, semi-micro balances, microbalances, and precision balances for applications ranging from routine sample preparation to high-resolution quantitative analysis.

Labs developing complete analytical or sample-preparation workflows can also source centrifuges, water baths, incubators, laboratory refrigerators, laboratory freezers, and other refurbished laboratory equipment from American Instrument Exchange.

Sartorius Secura 124-1S Analytical Balance FAQs

What is the maximum capacity of the Sartorius Secura 124-1S?

The balance has a maximum capacity of 120 g.

What is the readability?

The Secura 124-1S provides 0.1 mg, or 0.0001 g, readability.

Is the Secura 124-1S an analytical or semi-microbalance?

It is an analytical balance. The Secura 125-1S is the related semi-micro model with 0.01 mg readability.

Does the Secura 124-1S have internal calibration?

Yes. The balance incorporates Sartorius isoCAL automatic internal adjustment.

What is SQmin?

SQmin is a minimum-weight monitoring function that can alert operators when the sample weight is below a configured minimum.

What is Real-Time Level Support?

It is an electronic leveling assistance feature that alerts users when the balance is not properly leveled.

Can the Secura 124-1S be used for pharmaceutical weighing?

Yes. Its analytical readability, isoCAL adjustment, SQmin monitoring, and documentation features make it suitable for many pharmaceutical weighing applications, subject to the laboratory's validated procedures.

Does the balance have USB connectivity?

Yes. USB-Direct allows basic weighing-result transfer to compatible computers.

What is the weighing pan diameter?

The balance has a 90 mm diameter weighing pan.

What is the difference between the Secura 124-1S and 224-1S?

Both provide 0.1 mg readability, but the 124-1S has 120 g capacity while the 224-1S provides 220 g capacity.

Does the balance support below-balance weighing?

Yes. The Secura 124-1S supports below-balance weighing for appropriate specialized applications.

Is this Sartorius Secura 124-1S new or refurbished?

This unit is offered used and refurbished by American Instrument Exchange, with performance testing and a 90-day warranty.

Why purchase a refurbished Sartorius Secura 124-1S?

A refurbished Secura 124-1S provides analytical weighing performance, automatic internal adjustment, minimum-weight monitoring, electronic leveling assistance, and modern data-transfer capabilities at a lower acquisition cost than many comparable new analytical balances.

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.