Many laboratory procedures require temperatures below ambient while maintaining the precision and stability expected of a research-grade incubator. Whether performing biochemical oxygen demand (BOD) testing, culturing environmental microorganisms, conducting food quality studies, or evaluating seed germination, laboratories depend on consistent low-temperature incubation to produce accurate and reproducible results. The Thermo Scientific Precision PR505755R Refrigerated Incubator is designed specifically for these applications, combining a spacious 20 cubic foot (566 L) chamber with dependable refrigeration, microprocessor controls, and forced-air air circulation for reliable performance across an operating range of -10°C to +50°C.
Unlike conventional incubators that only provide heating, the PR505755R integrates both refrigeration and heating into a single system, allowing laboratories to maintain stable environmental conditions for a wide variety of microbiological and environmental testing protocols. Its large-capacity chamber accommodates more than 300 standard 300 mL BOD bottles, while features including programmable controls, over- and undertemperature protection, RS-232 communication capability, and corrosion-resistant construction make it an excellent solution for environmental, industrial, and research laboratories. Purchasing a refurbished Thermo Scientific Precision PR505755R from American Instrument Exchange provides an economical alternative to purchasing new while delivering the dependable performance laboratories expect from Thermo Scientific equipment.
20 cu. ft. (566 L) chamber capacity
Operating temperature range of -10°C to +50°C
Microprocessor temperature controller
Forced-air circulation for excellent chamber uniformity
Holds over 300 standard 300 mL BOD bottles
RTD temperature sensor
Digital temperature display with 0.1°C resolution
High- and low-temperature safety protection
RS-232 communication and recorder outputs
Access port for probes and external instrumentation
Four adjustable shelves included (expandable to six)
Corrosion-resistant aluminum chamber interior
Solid insulated door
115V operation
90-day warranty from American Instrument Exchange
Many laboratory protocols require temperatures well below room temperature while maintaining stable environmental conditions throughout extended incubation periods. The PR505755R was engineered to satisfy these requirements by combining precision refrigeration and heating into a single platform. This flexibility allows laboratories to perform refrigerated microbiological studies, BOD testing, environmental analysis, and elevated-temperature incubation without changing equipment.
A microprocessor controller continuously monitors chamber conditions using an RTD temperature sensor while forced-air circulation distributes conditioned air evenly throughout the chamber. This design promotes excellent temperature stability and uniformity across every shelf position, helping ensure that samples receive consistent incubation conditions regardless of their placement inside the chamber.
The Thermo Scientific Precision PR505755R is commonly used for:
Biochemical oxygen demand (BOD) testing
Water and wastewater analysis
Environmental microbiology
Food safety and quality testing
Beverage microbiology
Seed germination studies
Plant physiology research
Entomology
Aquatic organism studies
Pharmaceutical quality control
Industrial quality assurance
Academic microbiology research
Laboratories frequently pair refrigerated incubators like the PR505755R with laboratory refrigerators for media storage, ultralow temperature freezers for long-term sample preservation, biosafety cabinets for aseptic sample preparation, and benchtop centrifuges to support complete microbiology and environmental testing workflows.
The PR505755R is an excellent choice for municipal water and wastewater laboratories, environmental testing facilities, food and beverage quality control laboratories, agricultural research centers, pharmaceutical quality assurance laboratories, public health laboratories, university microbiology departments, and industrial research organizations. Its large-capacity chamber makes it particularly attractive for laboratories processing high sample volumes or conducting multiple long-term incubation studies simultaneously.
One of the defining advantages of the PR505755R is its exceptional capacity for biochemical oxygen demand testing. With room for more than 300 standard 300 mL BOD bottles, laboratories can process large testing batches within a single incubator while maintaining consistent environmental conditions throughout the chamber. This improves workflow efficiency, reduces the need for multiple incubators, and helps ensure comparable incubation conditions across every sample.
The spacious interior is equally well suited for petri dishes, culture bottles, flasks, environmental samples, and other laboratory containers. Four adjustable shelves are supplied as standard, with the option to expand to six shelves as laboratory throughput increases. RS-232 communication capability also allows laboratories to document chamber performance for quality assurance and regulatory compliance.
Consistent temperature control is essential for microbiological testing, environmental studies, and quality control applications where even small fluctuations can influence experimental results. The Thermo Scientific Precision PR505755R utilizes a microprocessor-based control system and precision RTD temperature sensor to maintain accurate chamber temperatures throughout the operating range. Combined with a forced-air circulation system, conditioned air is distributed evenly across every shelf position, helping minimize temperature gradients within the chamber.
Unlike passive convection incubators, forced-air circulation allows the PR505755R to recover more quickly following door openings while maintaining excellent temperature uniformity during extended incubation periods. This level of environmental stability is particularly valuable for laboratories conducting long-term BOD testing, microbiological culture work, and environmental monitoring programs where repeatability is critical.
The Thermo Scientific Precision PR505755R is designed to support a broad range of refrigerated laboratory applications. Its spacious chamber accommodates standard BOD bottles, petri dishes, Erlenmeyer flasks, culture tubes, media bottles, environmental water samples, food products, plant materials, seed trays, and a variety of laboratory containers used in microbiological and environmental testing.
Researchers commonly use refrigerated incubators such as the PR505755R for bacterial and fungal culture, environmental microbiology, water quality analysis, food safety testing, seed germination, aquatic biology studies, entomology research, and pharmaceutical quality assurance. The wide operating temperature range also provides flexibility for laboratories performing both refrigerated incubation and moderate elevated-temperature protocols within a single instrument.
| Specification | Details |
|---|---|
| Manufacturer | Thermo Scientific Precision |
| Model | PR505755R |
| Chamber Type | Refrigerated Incubator |
| Chamber Capacity | 20 cu. ft. (566 L) |
| Temperature Range | -10°C to +50°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Temperature Sensor | RTD |
| Temperature Display Resolution | 0.1°C |
| Air Circulation | Forced Air |
| Interior Material | Corrosion-Resistant Aluminum |
| Shelves Included | 4 Adjustable Shelves |
| Maximum Shelf Capacity | 6 Shelves |
| BOD Bottle Capacity | Over 300 (300 mL Bottles) |
| Communications | RS-232 and Recorder Outputs |
| Access Port | Yes |
| Interior Dimensions (W × D × H) | 20 × 26.5 × 57 in. |
| Exterior Dimensions (W × D × H) | 31 × 34 × 77 in. |
| Electrical Requirements | 115V, 60 Hz |
| Weight | Contact American Instrument Exchange |
Specifications are based on manufacturer documentation. Certain specifications may vary depending on production year and factory-installed options. Please verify installation requirements prior to purchase.
A refrigerated incubator can maintain temperatures below ambient, allowing laboratories to perform applications such as BOD testing, environmental microbiology, seed germination, and food quality studies that cannot be performed in conventional heated incubators.
The chamber accommodates more than 300 standard 300 mL BOD bottles, making it an excellent choice for municipal water laboratories, environmental testing facilities, and laboratories processing large testing volumes.
Yes. The incubator is designed for long-duration laboratory protocols and incorporates a microprocessor controller, forced-air circulation, and temperature safety protection to support continuous operation during extended testing programs.
The PR505755R can be used for environmental water samples, microbiological cultures, food and beverage products, seed germination studies, plant materials, insects, aquatic organisms, pharmaceutical samples, and other materials requiring controlled refrigerated incubation.
Forced-air circulation promotes even temperature distribution throughout the chamber while improving temperature recovery after the door has been opened. This helps maintain consistent incubation conditions regardless of where samples are placed within the chamber.
Yes. Although designed for refrigerated operation, the PR505755R also functions as a heated incubator with an operating range extending to +50°C, allowing laboratories to perform a wide variety of microbiological and environmental protocols using a single instrument.
Yes. RS-232 communication and recorder outputs allow laboratories to connect the incubator to external monitoring or data collection systems for documentation and quality assurance purposes.
A refurbished Thermo Scientific Precision PR505755R from American Instrument Exchange provides a dependable refrigerated incubation platform for microbiology, environmental testing, food quality, agricultural research, and pharmaceutical quality assurance laboratories at a significant savings compared to purchasing new equipment. With its 20 cubic foot chamber, -10°C to +50°C operating range, forced-air circulation, and capacity for more than 300 BOD bottles, the PR505755R is an excellent solution for laboratories requiring precise low-temperature incubation. Every unit is inspected and tested prior to shipment and includes a 90-day warranty for added confidence.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.