Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

VWR 89511-412 Forced Air Laboratory Oven

Fully Tested & Warrantied*
Brand : VWR
Product Code : SKU 3731C OVEN
Sold Out
⚠

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

VWR 89511-412 Forced Air Laboratory Oven – Used and Refurbished

The VWR 89511-412 Forced Air Laboratory Oven is a precision temperature-controlled drying and heating oven designed for laboratory applications requiring consistent heat distribution, rapid temperature recovery, and dependable thermal processing. Featuring a 104-liter (3.7 cu. ft.) stainless steel chamber, operating temperatures from 50°C to 250°C, and a microprocessor-based PID temperature controller, this VWR forced convection oven provides reliable performance for research, pharmaceutical, biotechnology, and industrial laboratories.

Unlike conventional gravity convection ovens, the VWR 89511-412 uses mechanically circulated heated air to distribute thermal energy throughout the chamber. This forced-air design promotes faster drying, improved temperature uniformity, and more consistent heating of compatible laboratory materials.

The oven incorporates adjustable shelving, a digital temperature controller with integrated timer, independent overtemperature protection, and dual-sensor safety features. Its stainless steel interior with rounded corners facilitates cleaning and helps maintain a durable working environment for routine laboratory applications.

This VWR 89511-412 Forced Air Oven is offered used and refurbished by American Instrument Exchange. Our experienced technicians inspect and test laboratory heating equipment before shipment, providing customers with substantial savings compared to purchasing new.

A 90-day warranty is included with this refurbished laboratory oven.

Key Features

  • VWR forced air laboratory drying oven, catalog number 89511-412

  • 104-liter (3.7 cu. ft.) stainless steel chamber

  • Temperature operating range of 50–250°C

  • Forced-air circulation for rapid and uniform heating

  • Microprocessor-based PID temperature controller

  • Digital temperature setting with 0.1°C resolution

  • Manufacturer-rated temperature fluctuation of ±0.4°C

  • Temperature uniformity of ±3.5°C under specified test conditions

  • Approximately 18-minute heat-up time under manufacturer test conditions

  • Approximately 3-minute temperature recovery time

  • Integrated timer for controlled heating procedures

  • Independent overtemperature protection

  • Dual-sensor safety features

  • Stainless steel interior with rounded corners for easier cleaning

  • Adjustable wire shelves for flexible sample placement

  • 120V electrical configuration

  • cCSAus-certified model design

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The VWR 89511-412 is a laboratory forced convection oven developed for applications requiring controlled heating, drying, and thermal conditioning.

Its 104-liter chamber provides substantial usable space for sample containers, laboratory glassware, metal components, and other compatible materials.

The oven uses an internal circulation fan to distribute heated air throughout the chamber, helping reduce temperature differences between locations and promoting consistent thermal exposure.

This approach is particularly beneficial when processing multiple samples simultaneously or performing procedures that require repeatable temperature conditions.

The integrated PID controller continuously adjusts heating output to maintain the selected temperature, while the timer provides convenient control over routine laboratory heating procedures.

The combination of chamber capacity, temperature performance, and straightforward operation makes the VWR 89511-412 suitable for a wide range of laboratory drying and heat-treatment applications.

Common Applications

The VWR 89511-412 is used for drying laboratory glassware, removing moisture from compatible samples, conditioning materials, heating laboratory components, and performing controlled thermal treatments.

Additional applications include drying powders and granules, preparing analytical samples, evaluating material stability, curing compatible coatings and resins, and conducting research involving elevated-temperature exposure.

The oven is also useful for industrial quality-control testing, materials science research, pharmaceutical development, and general laboratory drying procedures.

All samples and materials must be compatible with the oven's temperature range, forced-air environment, and safety requirements.

Key Specifications

Specification Details
Manufacturer VWR International
Catalog Number 89511-412
Equipment Type Forced Air Laboratory Oven
Chamber Capacity 104 L (3.7 cu. ft.)
Temperature Range 50–250°C
Temperature Setting Resolution 0.1°C
Temperature Fluctuation ±0.4°C
Temperature Uniformity ±3.5°C
Uniformity Test Method Manufacturer Rating Based on 27 Sensors
Heat-Up Time Approximately 18 Minutes
Temperature Recovery Time Approximately 3 Minutes
Temperature Controller Microprocessor-Based PID
Timer Integrated
Air Circulation Mechanically Forced Convection
Chamber Material Stainless Steel
Interior Width 18.3 in. (46.5 cm)
Interior Depth 14.5 in. (36.8 cm)
Interior Height 23.9 in. (60.7 cm)
Exterior Width 25.2 in. (64.0 cm)
Exterior Depth 25.2 in. (64.0 cm)
Exterior Height 32.3 in. (82.0 cm)
Shelving Adjustable Wire Shelves
Temperature Safety Overtemperature Protection and Dual-Sensor Safety
Electrical Requirements 120V AC
Frequency Verify Unit Nameplate
Shipping Weight Approximately 147.7 lb
Certification cCSAus-Certified Model Design
Stand and Casters Optional; Not Assumed Included
Condition Used / Refurbished
Warranty 90 Days

Specifications are based on VWR manufacturer documentation for catalog number 89511-412. Temperature uniformity, fluctuation, heat-up time, and recovery time represent manufacturer-rated performance under defined test conditions. Actual performance depends on chamber loading, operating temperature, ambient conditions, and equipment condition.

Ideal Laboratory Types

The VWR 89511-412 is well suited to pharmaceutical research laboratories, biotechnology facilities, analytical chemistry departments, academic research institutions, materials science laboratories, industrial quality-control facilities, and environmental testing laboratories.

Its 3.7 cu. ft. capacity makes it particularly useful for laboratories requiring a mid-sized drying oven capable of processing multiple samples or larger laboratory components.

Forced Air Circulation and Drying Performance

The primary advantage of the VWR 89511-412 is its forced-air convection system.

An internal fan circulates heated air throughout the chamber, promoting heat transfer between the air and the materials being processed.

Compared with gravity convection ovens, which rely primarily on natural air movement, forced-air systems can provide faster drying and more consistent temperature distribution.

Air circulation also helps remove moisture from exposed sample surfaces, making the oven useful for drying compatible glassware, containers, powders, and laboratory materials.

Drying efficiency depends on sample geometry, moisture content, loading arrangement, and the selected temperature.

Temperature Uniformity and Stability

The VWR 89511-412 is designed to provide consistent chamber temperatures during laboratory heating procedures.

The manufacturer specifies temperature fluctuation of approximately ±0.4°C and temperature uniformity of ±3.5°C under defined testing conditions.

Temperature fluctuation describes changes in temperature over time at a measurement location, while uniformity describes differences between locations within the chamber.

The manufacturer's uniformity specification is based on measurements from 27 sensors distributed throughout the chamber.

These performance characteristics are particularly important for laboratories performing material conditioning, sample drying, and repeatable thermal treatments.

Actual temperature performance should be evaluated under the conditions relevant to the laboratory's intended applications.

Rapid Heat-Up and Temperature Recovery

The VWR forced-air design supports efficient heating and recovery following door openings.

The manufacturer lists an approximately 18-minute heat-up time and a 3-minute recovery time under specified testing conditions.

Rapid temperature recovery is useful when laboratory personnel must load or unload samples during routine operations.

The oven's heating system and forced-air circulation work together to restore the selected chamber temperature after temporary disturbances.

Actual recovery times vary with chamber loading, operating temperature, ambient conditions, and the duration of door openings.

PID Temperature Controller

The VWR 89511-412 incorporates a microprocessor-based proportional-integral-derivative (PID) temperature controller.

PID control continuously adjusts heating output to reduce deviations between the selected temperature and measured chamber temperature.

This helps maintain stable operating conditions and reduces unnecessary temperature fluctuations.

The digital interface allows operators to select temperatures with 0.1°C setting resolution.

This resolution describes the controller's adjustment increment and should not be confused with absolute temperature accuracy or chamber uniformity.

Integrated Timer and Process Control

The oven includes an integrated timer to support routine laboratory heating and drying procedures.

Timed operation is useful for applications requiring a defined heating interval after the desired operating conditions have been established.

Laboratories can use the timer in conjunction with the temperature controller to develop consistent procedures for compatible materials.

The timer's exact operating modes should be confirmed against the installed controller and manufacturer instructions.

Overtemperature Protection and Safety Features

The VWR 89511-412 incorporates independent overtemperature protection and dual-sensor safety features.

These systems are intended to help protect the oven and its contents from excessive temperatures resulting from certain operating faults.

The manufacturer also identifies cCSAus certification for this oven series.

The safety features should be inspected during refurbishment and operated according to the manufacturer's instructions.

The oven is intended for compatible nonhazardous drying and heating applications. It should not be used for processing flammable solvents, explosive materials, or substances that can generate hazardous vapors unless the manufacturer expressly approves the application.

Stainless Steel Chamber and Adjustable Shelving

The VWR 89511-412 features a stainless steel interior designed for durability and routine laboratory cleaning.

Rounded interior corners help reduce areas where residues and debris can accumulate.

Adjustable wire shelves allow operators to configure the chamber for different sample heights and loading requirements.

Proper spacing between samples is important for maintaining effective air circulation.

Overloading the shelves or blocking air passages can reduce heating uniformity and increase drying time.

The exact number of shelves included with the refurbished oven should be confirmed before purchase.

VWR Forced Air Oven vs. Gravity Convection Oven

Forced-air and gravity convection ovens are designed for different laboratory heating requirements.

The VWR 89511-412 uses mechanical air circulation to promote faster heat transfer and more uniform chamber conditions.

Gravity convection ovens rely on natural air movement and may be preferred for certain delicate materials that should not be exposed to continuous airflow.

For routine drying, heat treatment, and material conditioning, forced-air circulation often provides advantages in processing speed and temperature consistency.

Laboratories should select the appropriate oven type based on sample sensitivity, drying requirements, and operating temperature.

Energy Efficiency and Operating Considerations

The VWR 89511-412 uses controlled electrical heating and chamber insulation to maintain the selected operating temperature.

Its PID controller regulates heating output as needed rather than applying maximum heat continuously.

Efficient chamber loading and minimizing unnecessary door openings can help reduce energy consumption and improve processing consistency.

The oven's actual electrical consumption depends on operating temperature, ambient conditions, loading, and heating duration.

Laboratories should confirm the individual unit's current and power requirements before installation.

Refurbishment and Testing by American Instrument Exchange

American Instrument Exchange inspects, tests, and reconditions used laboratory ovens before shipment.

For the VWR 89511-412, relevant testing includes evaluating the heating system, verifying temperature controller operation, inspecting the circulation fan, and checking the timer and safety controls.

The chamber, door gasket, shelving, electrical connections, and internal air passages should also be inspected.

Temperature performance can be evaluated using independent calibrated measurement equipment to verify heating operation and stability.

Customers requiring documented temperature uniformity testing, calibration records, or confirmation of particular accessories should discuss these requirements with AIE before purchasing.

This refurbished VWR forced air oven includes a 90-day warranty from American Instrument Exchange.

Shipping and Installation

The VWR 89511-412 measures approximately 25.2 inches wide, 25.2 inches deep, and 32.3 inches high.

The manufacturer lists a shipping weight of approximately 147.7 pounds.

The oven requires a stable, heat-resistant supporting surface or an appropriate manufacturer-compatible stand.

Installation requires suitable 120V electrical service, adequate ventilation, and appropriate clearance around the cabinet.

The manufacturer's operating instructions should be consulted for minimum side, rear, and overhead clearances.

Optional stands and casters are available for this oven family but should not be assumed included with the refurbished unit.

Before operation, laboratories should inspect the interior, confirm the circulation fan operates correctly, and verify that the temperature controller and overtemperature protection function as intended.

Related Equipment

Laboratories using the VWR 89511-412 may also require other laboratory drying ovens, vacuum ovens, laboratory incubators, laboratory water baths, and laboratory glassware washers.

American Instrument Exchange supplies used and refurbished laboratory heating, drying, and temperature-control equipment for pharmaceutical, biotechnology, academic, and industrial laboratories.

VWR 89511-412 Forced Air Oven FAQs

What is the VWR 89511-412 used for?

The VWR 89511-412 is a forced-air laboratory oven used for drying compatible samples, removing moisture, heating laboratory materials, and performing controlled thermal treatments.

What is the chamber capacity?

The oven has a 104-liter chamber, equivalent to approximately 3.7 cubic feet.

What is the temperature range?

The manufacturer specifies an operating temperature range of 50–250°C.

What is the advantage of forced-air circulation?

Forced-air circulation promotes faster heat transfer, more consistent chamber temperatures, and improved moisture removal compared with conventional gravity convection heating.

What is the temperature uniformity?

VWR specifies temperature uniformity of approximately ±3.5°C under defined manufacturer testing conditions.

Does the oven have a digital temperature controller?

Yes. The 89511-412 incorporates a microprocessor-based PID temperature controller with 0.1°C setting resolution.

Does the oven have a timer?

Yes. The oven includes an integrated timer for laboratory heating and drying procedures.

How quickly does the oven heat up?

The manufacturer lists an approximately 18-minute heat-up time under specified test conditions. Actual heat-up time depends on the selected temperature and operating conditions.

What are the interior dimensions?

The chamber measures approximately 18.3 inches wide, 14.5 inches deep, and 23.9 inches high.

What electrical service does the oven require?

The manufacturer specifies 120V electrical service. The exact current and frequency requirements should be verified on the individual unit's nameplate.

Can the VWR 89511-412 be used to dry flammable solvents?

No. This standard forced-air laboratory oven should not be used to dry materials that release flammable or explosive vapors unless the manufacturer specifically approves the application.

Are shelves included?

The manufacturer supplies adjustable wire shelves with this oven series. The number and condition of shelves included with the refurbished unit should be confirmed before purchase.

Does the refurbished oven include a warranty?

Yes. American Instrument Exchange includes a 90-day warranty on refurbished laboratory equipment.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.