Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

VWR GTVWG30CPGA Glass Door Laboratory Refrigerator

Fully Tested & Warrantied*
Brand : VWR
Product Code : SKU 4393M REFRIG
Sold Out

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

VWR GTVWG30CPGA Glass Door Laboratory Refrigerator

The VWR GTVWG30CPGA Glass Door Laboratory Refrigerator is a full-size upright refrigerator designed for dependable cold storage of reagents, media, biological materials, research samples, and other temperature-sensitive laboratory inventory. Featuring a glass viewing door, spacious upright chamber, adjustable shelving, and laboratory-oriented temperature control, this VWR refrigerator provides convenient refrigerated storage for busy research, biotechnology, pharmaceutical, clinical, and academic laboratories.

The glass-door configuration is particularly useful in laboratories where refrigerated materials are accessed frequently. Users can identify samples, reagents, media, and other inventory before opening the refrigerator, helping reduce unnecessary door-open time and associated temperature disturbances.

This used VWR GTVWG30CPGA refrigerator is refurbished and tested by American Instrument Exchange prior to shipment and includes a 90-day warranty.

Key Features

  • Full-size upright laboratory refrigerator

  • Glass viewing door for easy inventory identification

  • Designed for refrigerated laboratory storage

  • Adjustable shelving for flexible interior organization

  • Forced-air refrigeration supports temperature distribution throughout the chamber

  • Digital temperature monitoring and control

  • Interior lighting for improved visibility

  • Alarm functionality for added sample protection

  • Keyed door lock helps control access to stored materials

  • Casters facilitate positioning and installation

  • Suitable for reagents, media, biological samples, research materials, and other temperature-sensitive inventory

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The VWR GTVWG30CPGA provides laboratories with a combination of substantial refrigerated storage capacity and convenient visual access to stored materials. Unlike household or commercial refrigerators, laboratory refrigerators are designed around the requirements of scientific environments, where temperature monitoring, organized storage, and reliable operation are important considerations.

The unit's glass door allows researchers to locate materials before opening the refrigerator. This can be particularly valuable in shared laboratories, where frequent access by multiple users can otherwise result in extended door openings while samples or reagents are located.

Adjustable shelving provides flexibility for storing bottles, reagent containers, media, sample racks, boxes, and other laboratory materials of different sizes. The upright configuration also makes efficient use of laboratory floor space while providing substantially greater storage capacity than undercounter refrigerators.

For laboratories replacing an aging refrigerator or expanding available cold-storage capacity, a refurbished VWR GTVWG30CPGA can provide a cost-effective alternative to purchasing a comparable new laboratory refrigerator.

Common Applications

The VWR GTVWG30CPGA can be used for refrigerated storage of laboratory reagents, prepared media, buffers, biological samples, research materials, analytical standards, diagnostic materials, and other products requiring controlled refrigerated conditions.

Typical applications include molecular biology, biotechnology research, pharmaceutical development, biomedical research, microbiology, chemistry, clinical research, quality control, analytical testing, and general laboratory cold storage.

Because storage requirements vary considerably among laboratory materials, users should always verify that the refrigerator's operating conditions are appropriate for the specific samples, reagents, or products being stored.

Ideal Laboratory Types

The VWR GTVWG30CPGA is well suited for biotechnology companies, pharmaceutical laboratories, academic research institutions, universities, hospitals, biomedical research facilities, molecular biology laboratories, microbiology laboratories, analytical laboratories, clinical research facilities, and industrial quality-control laboratories.

Its glass-door design is especially useful in shared research environments and laboratories maintaining a large working inventory of frequently accessed reagents and supplies. Being able to visually locate materials before opening the refrigerator can improve workflow while helping reduce unnecessary temperature disturbances.

Temperature Recovery & Uniformity

Reliable temperature performance is an important consideration for any laboratory refrigerator. The VWR GTVWG30CPGA uses forced-air refrigeration to circulate cooled air through the chamber, helping maintain appropriate refrigerated conditions across the storage area.

Forced-air circulation is particularly useful in larger upright refrigerators because stored materials, shelves, and containers can influence airflow throughout the chamber. Maintaining appropriate spacing between stored items helps refrigerated air circulate effectively.

The glass door allows users to identify materials before opening the cabinet, potentially reducing door-open duration. Shorter door openings limit the amount of warmer laboratory air entering the chamber and can help the refrigerator return to its normal operating conditions more quickly following routine access.

Actual temperature performance and recovery will depend on ambient laboratory conditions, refrigerator loading, shelf arrangement, ventilation, door-opening frequency, and equipment condition.

Sample Storage Recommendations

Laboratories should organize the GTVWG30CPGA so refrigerated air can circulate around stored materials. Shelves should not be overloaded or arranged in a manner that substantially restricts airflow.

Frequently accessed reagents and samples can be positioned in easily visible and accessible locations. The glass door makes it possible to identify many stored materials before opening the cabinet, reducing the time required for retrieval.

Temperature-sensitive materials should not be placed directly against interior air outlets or other areas where local conditions may differ from the primary storage space. Laboratories maintaining high-value materials should also consider independent temperature monitoring and documented procedures for responding to temperature alarms, power failures, or refrigeration problems.

The GTVWG30CPGA should not be assumed to be suitable for flammable or volatile materials unless the individual unit is specifically labeled and rated for that purpose. Laboratories storing flammable materials should use equipment specifically designed for flammable-material storage.

Key Specifications

Specification VWR GTVWG30CPGA
Equipment Type Laboratory Refrigerator
Manufacturer VWR
Model GTVWG30CPGA
Configuration Upright
Door Type Glass
Refrigeration Forced-air
Shelving Adjustable
Temperature Control Digital
Interior Lighting Yes
Door Lock Keyed
Casters Yes
Condition Used / Refurbished
Warranty 90 days from American Instrument Exchange

Additional unit-specific specifications, including exact capacity, dimensions, temperature range, electrical requirements, and weight, should be verified from the equipment data plate or documentation for the individual GTVWG30CPGA offered by American Instrument Exchange.

Energy Efficiency & Operating Costs

Laboratory refrigerators typically operate 24 hours per day, making energy consumption and refrigeration efficiency important considerations over the life of the equipment.

Several factors affect actual energy consumption, including ambient laboratory temperature, refrigerator setpoint, frequency and duration of door openings, sample loading, ventilation, condenser condition, and refrigeration-system performance.

The glass-door configuration provides an operational advantage in frequently accessed laboratories because researchers can identify stored materials without opening the refrigerator. Reducing unnecessary door openings can decrease warm-air infiltration and reduce the amount of work required from the refrigeration system to restore chamber conditions.

Routine maintenance is also important. Keeping the condenser and ventilation areas clean and ensuring that door gaskets seal correctly can support efficient refrigeration performance and extend equipment life.

Refurbishment & Testing

This VWR GTVWG30CPGA glass-door laboratory refrigerator is supplied used and refurbished by American Instrument Exchange.

Before shipment, our technicians inspect, clean, and test the refrigerator to verify proper operation. Temperature-controlled laboratory equipment is tested using NIST-traceable temperature probes and data logging equipment as appropriate to confirm temperature performance.

The refrigerator is operated under refrigerated conditions to verify its ability to reach and maintain an appropriate laboratory refrigeration temperature. Temperature controls, displays, alarms, glass door, hinges, handles, door gasket, lock, shelves, interior lighting, electrical components, cabinet components, and refrigeration system are inspected for proper operation and physical condition.

Worn or defective components are repaired or replaced as necessary during the refurbishment process. The interior, shelving, glass door, and exterior cabinet are also thoroughly cleaned before the refrigerator is released for shipment.

Customers with specific temperature-testing or documentation requirements are encouraged to discuss those requirements with American Instrument Exchange before shipment. When practical, our technicians can address application-specific testing requests as part of the refurbishment process.

This refurbished VWR laboratory refrigerator includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation

The VWR GTVWG30CPGA is a full-size upright laboratory refrigerator. Customers should verify the dimensions of the individual unit before delivery and confirm adequate clearance through loading docks, doorways, hallways, elevators, and other areas along the delivery route.

The final installation location should provide adequate ventilation around the refrigerator and sufficient clearance for normal operation and service access. Laboratories should also verify the electrical requirements shown on the unit's data plate before installation.

After transportation and placement, the refrigerator should be allowed to stabilize as appropriate before being loaded with temperature-sensitive materials. Laboratories should confirm satisfactory operating temperature before transferring valuable inventory into the chamber.

American Instrument Exchange can arrange freight transportation throughout the United States and internationally. Customers requiring liftgate service, inside delivery, rigging, or other specialized transportation should discuss those requirements with AIE before shipment.

Related Laboratory Equipment

Laboratories requiring additional refrigerated storage can browse American Instrument Exchange's selection of laboratory refrigerators, including glass-door, solid-door, chromatography, undercounter, and specialty refrigerators from VWR, Thermo Scientific, Fisher Scientific, Panasonic, PHCbi, and other major manufacturers.

For materials requiring frozen storage, AIE also offers refurbished laboratory freezers and ultra-low temperature freezers for -20°C, -30°C, and -80°C applications.

American Instrument Exchange also maintains a large inventory of refurbished centrifuges, CO₂ incubators, and biosafety cabinets for laboratories expanding or replacing essential research equipment.

Frequently Asked Questions

What is the VWR GTVWG30CPGA used for?

The VWR GTVWG30CPGA is designed for refrigerated laboratory storage of compatible reagents, media, biological materials, research samples, analytical materials, and other temperature-sensitive laboratory inventory.

What is the advantage of a glass-door laboratory refrigerator?

A glass door allows users to see stored materials without opening the refrigerator. This can make inventory retrieval faster while reducing unnecessary door openings and associated temperature disturbances.

Is the GTVWG30CPGA a laboratory refrigerator?

Yes. The GTVWG30CPGA is intended for laboratory cold-storage applications rather than ordinary household food storage.

Does this VWR refrigerator have adjustable shelves?

Yes. Adjustable shelving allows laboratories to configure the chamber around bottles, reagent containers, sample racks, media, boxes, and other laboratory materials of different sizes.

Why is forced-air refrigeration useful in a laboratory refrigerator?

Forced-air refrigeration circulates cooled air through the chamber to support temperature distribution around stored materials. Proper loading remains important because densely packed containers can restrict airflow.

Can this refrigerator be used for flammable materials?

The GTVWG30CPGA should not be considered a flammable-storage refrigerator unless the specific unit is expressly labeled and rated for that application. Laboratories storing flammable or volatile materials should use a refrigerator specifically designed for flammable-material storage.

Is a glass-door refrigerator appropriate for frequently accessed reagents?

Yes. Glass-door refrigerators can be particularly convenient for frequently accessed laboratory inventory because researchers can locate materials before opening the door, reducing search time with the cabinet open.

Can this refrigerator be used for general biotechnology research?

Yes. A full-size VWR laboratory refrigerator can provide useful refrigerated storage for biotechnology, molecular biology, pharmaceutical research, academic research, and other life-science applications, provided the temperature requirements of the stored materials fall within the unit's operating capabilities.

How does American Instrument Exchange test refurbished laboratory refrigerators?

American Instrument Exchange operates and tests refurbished temperature-controlled equipment before shipment. NIST-traceable temperature probes and data logging equipment are used as appropriate to verify temperature performance, while refrigeration, electrical, control, alarm, door, gasket, and cabinet components are inspected for proper operation.

Does this refurbished VWR GTVWG30CPGA include a warranty?

Yes. This used and refurbished VWR GTVWG30CPGA glass-door laboratory refrigerator includes a 90-day warranty from American Instrument Exchange unless otherwise noted.

Testing Procedures for Used and Refurbished Laboratory Refrigerators
Ensure Temperature Stability and Cold Storage Accuracy

Used and refurbished laboratory refrigerators from American Instrument Exchange are thoroughly tested to ensure reliable cold storage performance, temperature accuracy, and compliance with laboratory safety and storage standards. Each unit undergoes a detailed inspection and functional verification to meet the requirements of clinical, pharmaceutical, research, and industrial labs.

Why Testing Used Laboratory Refrigerators Is Essential

Before a laboratory refrigerator is reintroduced into any laboratory setting, it must be carefully tested for:

• Temperature uniformity and stability
• Cooling system integrity and compressor function
• Door seal performance and insulation effectiveness
• Electrical safety and compliance with lab standards

Thorough testing minimizes the risk of temperature excursions, product loss, and system failures—especially critical for storing reagents, vaccines, biological samples, pharmaceuticals, and temperature-sensitive materials.

Our structured testing protocol ensures refurbished lab refrigerators deliver consistent, dependable performance across all makes and models.

Key Testing Procedures for Refurbished and Used Laboratory Refrigerators

1. Initial Visual Inspection
• Check exterior surfaces, hinges, and door gaskets for wear, corrosion, or damage
• Inspect power cords, plugs, and control panels for fraying or visible defects
• Verify that shelves, racks, and internal compartments are present and functional

2. Functional Testing
• Power on the refrigerator and verify that display screens, alarms, and controls function properly
• Test door latches and sealing mechanisms to ensure secure closure and insulation
• Run preliminary temperature cycles to observe startup behavior and cooling response

3. Temperature and Stability Testing
• Test internal temperature sensors and controllers using thermometers/probes
• Monitor temperature at multiple points within the chamber over an extended period
• Verify accuracy across user-defined setpoints (e.g., +4°C, +2°C to +8°C range)

4. Cooling System and Compressor Evaluation
• Test compressor startup, cycling, and operating noise levels
• Inspect condenser coils and fans for proper function and cleanliness
• Check refrigerant pressure (if applicable) and confirm there are no leaks or system inefficiencies

5. Electrical Safety and Compliance Checks
• Ensure all internal and external electrical components are properly grounded
• Perform insulation resistance and leakage current tests
6. Final Quality Assurance Checklist
• Run full operational tests over a 24-hour period
• Document temperature logs, control responsiveness, and system performance
• Complete a detailed service report

All refurbished laboratory refrigerators from American Instrument Exchange are backed by our rigorous testing standards and quality commitment. From vaccine storage to reagent preservation, you can count on consistent cold storage performance from day one.

Repair and Refurbishment Protocol for Used Laboratory Refrigerators
Cold Storage Performance from American Instrument Exchange

At American Instrument Exchange, every used laboratory refrigerator we offer is subjected to a comprehensive repair and refurbishment protocol. Whether it’s a general-purpose lab refrigerator, pharmaceutical-grade unit, or undercounter model, our goal is to restore each system to peak performance—ensuring consistent temperature control and reliable to laboratory storage standards.

Why Choose a Refurbished Laboratory Refrigerator from American Instrument Exchange?

• Fully tested for cold storage accuracy and operational safety
• Backed by a warranty
• Cost-effective alternative to new refrigeration equipment
• Sustainably refurbished to reduce environmental impact
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every laboratory refrigerator from American Instrument Exchange follows a detailed, multi-stage process to ensure top-tier performance and reliability:

1. Initial Intake & Inspection

• Visual inspection for dents, corrosion, or structural damage
• Mechanical check of door hinges, gaskets, seals, and internal components
• Documentation of missing parts or areas requiring repair or replacement

2. Cleaning and Decontamination

• Internal and external cleaning using non-abrasive, lab-safe cleaners
• Decontamination/cleaning of all surfaces to remove biological or chemical residues
• Thorough cleaning of shelving, drawers, and removable interior parts

3. Mechanical and Electrical Repairs

• Replacement or repair of worn mechanical parts (door latches, seals, hinges, etc.)
• Inspection and restoration of control interfaces, thermostats, sensors, and displays
• Evaluation of wiring, relays, fuses, and power supply components for safety and integrity

4. Refrigeration System and Compressor Evaluation

• Testing of compressor function, condenser coils, and evaporators
• Inspection for refrigerant leaks and pressure performance (if applicable)
• Verification of proper airflow, fan operation, and defrost cycles

5. Temperature and Performance Testing

• Testing of temperature sensors and control boards
• Verification of temperature stability and uniformity throughout the chamber
• Testing of multiple setpoints (e.g., +2°C to +8°C) over extended operating periods

6. Safety and Compliance Checks

• Inspection of grounding and electrical insulation per lab safety standards
• Testing of alarm systems (if applicable) for temperature excursions or power failure

7. Final Quality Control and Documentation

• Multi-day operational test under real-world conditions
• Final cleaning, inspection, and performance validation
• Detailed service report with temperature logs, repair notes, and certification of refurbishment

Trust the Experts at American Instrument Exchange

With over 50 years of industry experience, American Instrument Exchange is a leading provider of high-quality refurbished laboratory equipment. Our proven laboratory refrigerator refurbishment protocol ensures consistent, accurate cold storage—so you can safeguard your samples, reagents, and research materials with confidence.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.