Tuttnauer Valueklave 1730 Manual Tabletop Autoclave
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Facilities that need reliable steam sterilization in an exceptionally compact tabletop format can benefit from the Tuttnauer Valueklave 1730 Manual Autoclave, also identified in current Tuttnauer literature as the 1730MK Valueklave. With a 7.5-liter chamber, quick-cycle performance, straightforward manual controls, three instrument trays, and standard 120 V operation, the Valueklave 1730 provides a practical sterilization solution for laboratories, veterinary facilities, medical and dental practices, educational institutions, and other professional environments with modest load requirements.
American Instrument Exchange is a distributor of brand-new Tuttnauer autoclaves and sterilizers, supplying laboratories and professional facilities throughout Massachusetts, New England, the Northeast, and across the United States. The Tuttnauer Valueklave 1730 is supplied new from the manufacturer and includes the applicable Tuttnauer manufacturer’s warranty.
The Valueklave 1730 is the smallest-capacity model in Tuttnauer’s manual autoclave lineup. Its compact 7.5-liter chamber and quick-cycle design make it particularly attractive for organizations that process small instrument loads and want to minimize both equipment footprint and cycle turnaround. For facilities that do not need the larger chamber capacity of a 2340M or 2540M, the Valueklave offers a focused combination of speed, simplicity, and economy.
Brand-new Tuttnauer manual tabletop steam autoclave
Compact 7.5-liter / 2-gallon chamber
Approximately 6.7-inch-diameter × 13.4-inch-deep chamber
Three instrument trays
Capacity for two half-size standard cassettes
Quick-cycle KwiKlave-style heating performance
Approximately 12-minute standard unwrapped cycle from a cold start
Approximately 9-minute standard unwrapped cycle from a hot start
Straightforward manual/electromechanical controls
Durable stainless steel chamber and door
Double locking safety system
Automatic overheat protection
Low-water protection
120 V, 50–60 Hz operation
Approximately 1,350 W power requirement
Extremely compact benchtop footprint
Brand new from Tuttnauer
Includes Tuttnauer manufacturer’s warranty
The Tuttnauer Valueklave 1730 is a compact manual steam autoclave designed for facilities that need dependable routine sterilization without the chamber capacity, electrical demand, or footprint of a larger sterilizer.
Tuttnauer currently identifies the platform as the 1730MK Valueklave, reflecting its place within the company’s quick-cycle MK family. The system combines a small 7.5-liter chamber with a relatively high-powered heating system for its size, allowing it to reach sterilization conditions quickly and support rapid turnaround of appropriate unwrapped instrument loads.
The chamber measures approximately 170 mm in diameter by 340 mm deep, or about 6.7 inches in diameter by 13.4 inches deep. This compact chamber is designed for relatively small instrument quantities rather than bulk laboratory loads.
Three trays provide multiple loading levels within the chamber. Tuttnauer lists capacity for two half-size standard cassettes, making the Valueklave particularly suitable for clinics, small laboratories, and other facilities processing limited instrument loads throughout the day.
The Valueklave uses straightforward manual controls instead of touchscreen electronics, Wi-Fi connectivity, or advanced programmable software. For trained users with established sterilization procedures, this simple operating architecture can be a major advantage.
The compact design also makes the Valueklave easy to integrate into crowded workspaces. Overall dimensions are only about 17 to 18 inches in width and depth and approximately 12 inches high, allowing the system to fit into many areas where a larger tabletop autoclave would be impractical.
For organizations that want factory-new equipment but do not need large chamber capacity, the Valueklave 1730 provides an economical entry point into Tuttnauer’s tabletop autoclave lineup.
Sterilization of compatible small reusable instruments
Processing of unwrapped solid instruments
Veterinary instrument sterilization
Medical and clinical instrument processing
Dental and procedural workflows
Academic teaching laboratories
Small research laboratories
Microbiology support applications
Small-volume biotechnology workflows
Secondary or backup sterilization capacity
Satellite laboratory or clinic locations
Facilities with limited benchtop space
The Tuttnauer Valueklave 1730 is particularly well suited for organizations whose sterilization needs are relatively modest and predictable.
Small research laboratories may use the Valueklave for compatible tools and reusable instruments when a larger autoclave would provide substantially more capacity than needed. Its compact dimensions also make it useful in laboratories where countertop space is at a premium.
Veterinary, dental, medical, and procedural facilities may appreciate the quick-cycle performance when processing small quantities of instruments repeatedly throughout the day.
Academic teaching laboratories can also benefit from the simple manual controls. The straightforward operating format allows trained personnel to work with a conventional steam sterilizer without requiring advanced electronic interfaces or network configuration.
Larger institutions may use the Valueklave as secondary or satellite sterilization equipment. A large facility with centralized sterilization may still benefit from a compact autoclave positioned near a particular procedure room, laboratory, or department for appropriate small loads.
The 7.5-liter chamber is intentionally small. Facilities routinely processing larger instrument batches, glassware, or other higher-volume loads should consider the Tuttnauer 2340M, 2540M, or larger models rather than selecting the Valueklave solely for its fast cycle time.
The Tuttnauer Valueklave 1730 uses saturated steam under pressure to process compatible heat- and moisture-resistant instruments.
The system uses gravity displacement rather than active pre-vacuum air removal. Steam enters the chamber and displaces cooler air as the chamber and load are heated to sterilization conditions.
This straightforward method is well suited to appropriate solid instrument loads when correct loading procedures are followed.
The manual/electromechanical controls give trained operators direct control over operation and avoid the complexity of touchscreen interfaces or computerized cycle-management systems.
Tuttnauer also incorporates several safety features into the manual platform. Current manufacturer information lists a double locking safety device, steam-pressure lock, door-failure protection, automatic overheat shutoff, and insufficient-water protection.
Facilities requiring active pre-vacuum processing, advanced drying, electronic cycle documentation, or more complex load capability should compare the Valueklave with Tuttnauer’s automatic T-Top, T-Edge, or other advanced sterilizer platforms.
The Tuttnauer Valueklave 1730 provides approximately 7.5 liters, or 2 gallons, of chamber capacity.
The cylindrical chamber measures approximately 6.7 inches in diameter by 13.4 inches deep, or 170 × 340 mm. Tuttnauer’s current technical manual confirms these chamber dimensions.
The system includes three trays measuring approximately 11.4 to 11.6 inches deep × 4.5 to 4.7 inches wide × 0.8 inches high, depending on the specific production documentation. Tuttnauer lists capacity for two half-size standard cassettes.
The small chamber is paired with relatively quick cycle performance. Current Tuttnauer MK Series literature lists a standard unwrapped cycle of approximately 12 minutes from a cold start and approximately 9 minutes from a hot start. Cycle times include heat-up, sterilization exposure, and exhaust and may vary with instrument load and voltage.
This makes the Valueklave particularly effective when a facility needs to process small loads quickly rather than maximize capacity per cycle.
For organizations comparing autoclaves, the tradeoff is straightforward: a larger chamber can process more material during each cycle, while the compact Valueklave minimizes equipment size and provides rapid turnaround for smaller loads.
The Tuttnauer Valueklave 1730 is a strong choice for facilities that prioritize compact size, fast routine cycles, manual simplicity, and economical new-equipment acquisition.
The first consideration should be chamber capacity. At only 7.5 liters, the Valueklave is substantially smaller than the 19-liter 2340M or 23-liter 2540M.
That smaller capacity is not necessarily a disadvantage. Facilities that rarely fill a larger chamber may benefit from using a smaller sterilizer designed around their actual load size.
Cycle speed is another important consideration. The Valueklave’s quick heating system allows appropriate unwrapped instrument loads to be processed relatively quickly, making it useful where instrument turnaround is more important than batch size.
Available counter space can also favor the Valueklave. Its compact cabinet measures approximately 17.4 inches wide × 17.9 inches deep × 12 inches high, depending on the current production reference, making it one of Tuttnauer’s smallest manual sterilizers.
Automation requirements should also be considered. The Valueklave is intentionally simple. Facilities seeking touchscreen operation, electronic cycle documentation, Wi-Fi connectivity, advanced drying, or active vacuum processing should select a more sophisticated Tuttnauer platform.
American Instrument Exchange can help customers compare the Valueklave 1730 with the 2340M, 2540M, and other Tuttnauer models based on chamber size, throughput, available space, automation requirements, and budget.
| Specification | Details |
|---|---|
| Manufacturer | Tuttnauer |
| Model | Valueklave 1730 / 1730MK |
| Series | Valueklave / MK Series |
| Condition | Brand new from manufacturer |
| Sterilizer Type | Compact manual gravity-displacement tabletop steam autoclave |
| Chamber Capacity | 7.5 L / 2 gal |
| Chamber Dimensions | 6.7 in diameter × 13.4 in deep (170 × 340 mm) |
| Exterior Dimensions | Approximately 17.4 in W × 17.9 in D × 12 in H (440 × 455 × 305 mm) |
| Maximum Depth with Door Open | Approximately 29.5 in / 750 mm |
| Chamber Construction | Stainless steel |
| Door Construction | Stainless steel |
| Number of Trays | 3 |
| Tray Dimensions | Approximately 11.4–11.6 in D × 4.5–4.7 in W × 0.8 in H |
| Standard Cassette Capacity | 2 half-size cassettes |
| Sterilization Method | Saturated steam under pressure |
| Air Removal | Gravity displacement |
| Control System | Manual / electromechanical |
| Standard Unwrapped Cycle – Cold Start | Approximately 12 minutes |
| Standard Unwrapped Cycle – Hot Start | Approximately 9 minutes |
| Safety Features | Double locking system, steam-pressure lock, overheat protection, low-water protection |
| Electrical Requirements | 120 V, 50–60 Hz for U.S. configuration |
| Current | Approximately 11.3 A |
| Power Consumption | Approximately 1,350 W |
| Installation Type | Benchtop |
| Net Weight | Approximately 20 kg / 44 lb |
| Published Shipping Weight | Approximately 25 kg / 55 lb |
| Warranty | Tuttnauer manufacturer’s warranty |
Current specifications are based on Tuttnauer’s current MK Series information and manufacturer documentation for the 1730 platform. Earlier Valueklave literature lists slightly different exterior dimensions and cycle times, so customers should confirm the current production configuration, included accessories, electrical requirements, and warranty terms with American Instrument Exchange when ordering.
The compact Tuttnauer Valueklave 1730 is relatively simple to install.
The current U.S. configuration operates on 120 V, 50–60 Hz electrical service and uses approximately 1,350 W of power.
The autoclave should be placed on a sturdy, level countertop with enough clearance for ventilation, service access, door movement, loading, and unloading.
Although the cabinet itself is compact, the open door increases total required depth to approximately 29.5 inches, so facilities should consider working clearance rather than cabinet dimensions alone.
Tuttnauer’s installation instructions specify adding approximately 10–12 ounces of water to the Valueklave chamber before operation and filling the reservoir with distilled water.
The system generates steam internally and does not require a building steam connection.
Appropriate distilled water and routine maintenance can help reduce mineral deposits and support reliable operation of the chamber, heater, valves, and associated components.
American Instrument Exchange supplies brand-new Tuttnauer autoclaves directly to laboratories and professional facilities throughout New England, the Northeast, and across the United States.
The Valueklave 1730 is particularly attractive for facilities that want factory-new equipment but do not need a large or highly automated sterilizer. Its compact chamber, fast cycle performance, manual controls, and standard electrical requirements make it a practical entry point into Tuttnauer’s sterilization equipment lineup.
American Instrument Exchange can help customers determine whether the Valueklave provides enough chamber capacity for their actual loads or whether stepping up to a 2340M, 2540M, or another Tuttnauer model would provide better long-term value.
Our Haverhill, Massachusetts location gives laboratories, universities, veterinary facilities, healthcare organizations, biotechnology companies, and other customers throughout Massachusetts and New England a regional source for new Tuttnauer equipment.
Because American Instrument Exchange supplies both new Tuttnauer autoclaves and professionally refurbished sterilizers, customers can compare options based on capacity, warranty preferences, required features, budget, and project timing.
Customers can contact American Instrument Exchange for current pricing, availability, shipping information, electrical configuration, and assistance selecting the appropriate Tuttnauer autoclave.
Yes. American Instrument Exchange offers the Valueklave 1730 brand new from Tuttnauer rather than as a used or refurbished autoclave.
Tuttnauer currently identifies the quick-cycle manual platform as the 1730MK (Valueklave), while some manufacturer support documentation and earlier product literature refer to it simply as the Valueklave 1730. Both designations are commonly associated with the compact 7.5-liter platform.
The Valueklave has approximately 7.5 liters, or 2 gallons, of chamber capacity.
The chamber measures approximately 6.7 inches in diameter by 13.4 inches deep, or 170 × 340 mm.
The Valueklave includes three instrument trays and has capacity for approximately two half-size standard cassettes.
Current Tuttnauer MK Series literature lists the standard unwrapped cycle at approximately 12 minutes from a cold start and approximately 9 minutes from a hot start. Actual cycle times can vary depending on load and electrical conditions.
No. The Valueklave is a manual/semi-automatic autoclave designed around straightforward electromechanical controls.
No. The Valueklave uses gravity displacement rather than active pre-vacuum air removal.
The current U.S. configuration operates on approximately 120 V, 50–60 Hz power and uses roughly 1,350 W.
No. The system generates steam internally.
The cabinet measures approximately 17.4 inches wide × 17.9 inches deep × 12 inches high. Facilities should allow additional depth for the front door, which increases total depth to approximately 29.5 inches when open.
The Valueklave has a much smaller 7.5-liter chamber compared with the 19-liter 2340M. The Valueklave is better suited for smaller, faster loads and limited bench space, while the 2340M provides substantially greater batch capacity.
The 2540M provides approximately 23 liters of chamber capacity compared with 7.5 liters for the Valueklave. Facilities processing larger instrument quantities will generally benefit from the 2540M, while low-volume users may prefer the smaller Valueklave.
The Valueklave is particularly well suited for small laboratories, veterinary facilities, clinics, educational settings, and other organizations that need rapid sterilization of relatively small instrument loads.
Yes. Brand-new Tuttnauer equipment purchased through American Instrument Exchange includes the applicable Tuttnauer manufacturer’s warranty. Current warranty terms should be confirmed when ordering.
Yes. American Instrument Exchange supplies new Tuttnauer sterilization equipment throughout Massachusetts, New Hampshire, Maine, Vermont, Rhode Island, Connecticut, the broader Northeast, and nationwide.
Yes. American Instrument Exchange can help customers compare the Valueklave 1730 with larger Tuttnauer models based on actual instrument dimensions, daily load volume, available counter space, cycle requirements, and budget.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.