Mettler Toledo MS3002TS Precision Balance

Fully Tested & Warrantied*
Product Code : SKU 0671N BALANCE
Date In: 6/13/2025

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Mettler Toledo MS3002TS Precision Balance – Used & Refurbished

The Mettler Toledo MS3002TS Precision Balance is a versatile laboratory balance combining a 3.2 kg weighing capacity with 0.01 g readability, fast stabilization, automatic internal adjustment, and an intuitive 7-inch color touchscreen. Designed for efficient routine weighing, formulation, sample preparation, quality control, and other quantitative laboratory applications, the MS3002TS provides an excellent balance of capacity, resolution, speed, and ease of use.

Available used and refurbished from American Instrument Exchange, the Mettler Toledo MS3002TS provides laboratories with proven Mettler Toledo precision weighing technology at a significantly lower acquisition cost than purchasing comparable new equipment. Each balance is inspected, cleaned, calibrated using NIST-traceable weights, and tested for weighing accuracy and repeatability before shipment and includes a 90-day warranty from American Instrument Exchange.

Key Features

  • 3.2 kg / 3,200 g maximum weighing capacity

  • 10 mg / 0.01 g readability

  • Typical repeatability of 0.007 g / 7 mg

  • Typical USP minimum weight of approximately 14 g

  • FACT automatic internal adjustment

  • Proven MonoBloc weighing cell

  • Approximately 1.5-second settling time

  • Large 7-inch color TFT touchscreen

  • Touchscreen can be operated while wearing common laboratory gloves

  • LevelControl provides leveling guidance

  • MiniWeigh helps determine whether sample weights meet defined minimum-weight requirements

  • Password protection and user-management capabilities

  • Large 200 × 170 mm weighing pan

  • USB, Ethernet, and RS232 connectivity

  • Optional Bluetooth connectivity

  • Used, refurbished, calibrated, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Mettler Toledo MS3002TS is designed for laboratories that need greater capacity than a conventional analytical balance while still requiring hundredth-of-a-gram resolution. Its 3.2 kg capacity and 0.01 g readability make it a versatile choice for sample preparation, formulation, reagent weighing, quality control, and general quantitative laboratory work.

The MS-TS series combines Mettler Toledo's proven MonoBloc weighing cell with a large 7-inch color TFT touchscreen. The interface is designed for straightforward operation and can be used while wearing common cotton, silicone, or rubber laboratory gloves, helping users avoid unnecessary interruptions during sample handling.

The MS3002TS also incorporates FACT automatic internal adjustment, LevelControl leveling guidance, MiniWeigh functionality, password protection, and multiple connectivity options. These features provide a more sophisticated laboratory workflow than a basic top-loading balance while retaining the open weighing surface and easy sample access expected from a precision balance.

For laboratories that do not require the sub-milligram resolution of an analytical balance, the MS3002TS offers an effective combination of useful capacity, 10 mg readability, rapid stabilization, and convenient touchscreen operation.

Common Applications

The Mettler Toledo MS3002TS is well suited for routine laboratory weighing procedures involving samples, reagents, ingredients, containers, and other materials within its 3.2 kg capacity range.

Pharmaceutical and biotechnology laboratories can use the MS3002TS for formulation, media and buffer preparation, reagent preparation, component weighing, sample preparation, and quality-control procedures.

Chemical laboratories can use the balance for compound preparation, percentage weighing, formulation development, reagent preparation, and routine quantitative work. Its 3.2 kg capacity provides sufficient room for many samples to be weighed directly in beakers, bottles, flasks, and other laboratory vessels.

Food and beverage, cosmetics, materials science, environmental, academic, and industrial laboratories can also use the MS3002TS for ingredient weighing, sample preparation, quality testing, formulation, and other procedures requiring reliable 0.01 g resolution.

Ideal Laboratory Types

The MS3002TS is a strong choice for pharmaceutical, biotechnology, chemical, food and beverage, cosmetics, materials science, environmental, academic, manufacturing, industrial research, and quality-control laboratories.

Its combination of 3.2 kg capacity and 10 mg readability places it in a useful middle ground between high-resolution analytical balances and larger-capacity precision balances.

For many routine laboratory procedures, 0.01 g readability provides ample resolution while the 3.2 kg capacity leaves enough room for containers and tare weight. The open weighing pan also makes it easier to work with larger vessels than would typically be practical inside the enclosed draft shield of an analytical balance.

Precision Weighing Performance

The Mettler Toledo MS3002TS provides 10 mg (0.01 g) readability across its 3.2 kg weighing range, making it suitable for a broad range of quantitative laboratory procedures.

Mettler Toledo specifies typical repeatability of approximately 7 mg, with a repeatability limit value of 10 mg. Typical linearity deviation is approximately 6 mg, with a specified linearity deviation of 20 mg.

The balance has a typical settling time of approximately 1.5 seconds, allowing measurements to stabilize quickly during repetitive weighing procedures.

This combination of capacity, resolution, and speed makes the MS3002TS particularly useful for laboratories performing multiple weighing procedures throughout the day. It provides significantly finer resolution than ordinary bench scales while avoiding the lower capacities and more restrictive sample handling associated with analytical and microbalances.

Minimum Sample Weight & USP Applications

Maximum capacity and readability alone do not determine whether a balance is suitable for a particular quantitative procedure. Laboratories operating under USP requirements should also consider the minimum sample weight necessary to achieve the required measurement uncertainty.

Mettler Toledo specifies a typical USP minimum weight of approximately 14 g for the MS3002TS under specified conditions. The manufacturer also specifies a typical minimum weight of approximately 1.4 g at U=1%, k=2.

The MS3002TS also incorporates Mettler Toledo's MiniWeigh functionality, which can help operators recognize whether the current sample weight meets established minimum-weight requirements.

Actual minimum weight can vary according to installation conditions, balance performance, environmental influences, measurement uncertainty requirements, and laboratory procedures.

For regulated or validated applications, laboratories should establish minimum weight according to their own qualification procedures and applicable quality requirements rather than relying exclusively on published typical values.

Controlling Drafts, Vibration & Environmental Influences

Although the MS3002TS is less sensitive to minor environmental disturbances than a microbalance or high-resolution analytical balance, air movement, vibration, temperature fluctuations, unstable work surfaces, and improper leveling can still influence weighing accuracy and repeatability.

The balance's LevelControl system helps operators identify leveling problems and guides them through the leveling process. Proper leveling is particularly important when a precision balance is moved, repositioned, or installed at a new workstation.

The large open weighing pan provides convenient access for bottles, beakers, flasks, containers, and other laboratory vessels without requiring users to work inside a conventional draft chamber.

For best performance, the MS3002TS should be installed on a rigid, level surface away from strong HVAC airflow, frequently opened doors, direct sunlight, centrifuges, shakers, compressors, and other equipment capable of transmitting vibration.

Calibration & Internal Adjustment

The MS3002TS incorporates Mettler Toledo's FACT automatic internal adjustment, allowing the balance to automatically adjust its weighing system as operating conditions change.

Internal adjustment can help compensate for environmental influences such as temperature changes and reduces reliance on manually initiated adjustment procedures during routine laboratory operation.

American Instrument Exchange also performs external calibration as part of its balance testing procedure using NIST-traceable calibration weights.

Laboratories operating under GLP, GMP, USP, or internal quality systems may still require scheduled performance verification, documented calibration, and qualification according to their own procedures. Automatic internal adjustment should therefore be considered one component of a complete balance quality-control program rather than a substitute for laboratory-specific calibration requirements.

Touchscreen, User Management & Connectivity

One of the distinguishing features of the MS3002TS is its 7-inch color TFT touchscreen, which provides a substantially larger and more intuitive interface than conventional button-operated laboratory balances.

Large 18 mm digits make weighing results easy to read, while the touchscreen can be operated through common laboratory gloves. This can be particularly useful when the balance is incorporated into sample-preparation, formulation, or quality-control workflows where operators routinely wear personal protective equipment.

Password protection and user-management capabilities can help control access to balance settings and reduce unintended configuration changes.

The MS3002TS also provides extensive connectivity, including USB-A, USB-B, Ethernet/LAN, and RS232 interfaces, with optional Bluetooth connectivity available. These connections allow integration with compatible printers, computers, barcode readers, and other laboratory peripherals.

Electronic data transfer can reduce reliance on handwritten transcription and make the MS3002TS easier to incorporate into standardized laboratory workflows.

Key Specifications

Specification Mettler Toledo MS3002TS
Balance Type Precision / Toploading Balance
Maximum Capacity 3.2 kg / 3,200 g
Readability 10 mg / 0.01 g
Repeatability 10 mg
Typical Repeatability 7 mg
Typical USP Minimum Weight 14 g
Typical Minimum Weight (U=1%, k=2) 1.4 g
Linearity Deviation 20 mg
Typical Linearity Deviation 6 mg
Settling Time Approx. 1.5 seconds
Adjustment Internal / automatic FACT
Weighing Pan 200 × 170 mm
Display 7-inch color TFT touchscreen
Overall Dimensions 194 mm W × 347 mm D × 99 mm H
Weighing Cell MonoBloc
Leveling LevelControl
Minimum Weight Assistance MiniWeigh
Connectivity USB-A, USB-B, Ethernet/LAN, RS232
Wireless Connectivity Optional Bluetooth
User Management Password protection / user rights
Legal for Trade No (standard MS3002TS/00)

Choosing Between a Precision Balance and Analytical Balance

A precision balance and analytical balance are designed for different weighing priorities. Choosing between them depends on the smallest quantity that must be accurately measured, maximum combined sample and container weight, required measurement uncertainty, and laboratory workflow.

Analytical balances generally provide substantially finer readability—commonly 0.1 mg—but usually have lower maximum capacities and enclosed draft shields designed to protect sensitive measurements from air movement.

The MS3002TS provides 3.2 kg capacity with 0.01 g readability, trading extreme analytical sensitivity for greater capacity, a larger open weighing surface, and easier handling of containers and routine samples.

This makes the MS3002TS particularly appropriate for formulation, reagent preparation, sample preparation, ingredient weighing, and general quantitative work involving gram-to-kilogram quantities.

Laboratories performing both small-sample analytical measurements and larger preparation procedures may benefit from maintaining both analytical and precision balances so each weighing task can be performed on an instrument appropriately matched to the required capacity and resolution.

Refurbishment & Performance Testing

Every used Mettler Toledo MS3002TS sold by American Instrument Exchange is inspected, cleaned, refurbished as necessary, calibrated, and tested before shipment.

Because weighing performance is the primary function of a precision balance, testing goes beyond simply confirming that the instrument powers on and displays a stable weight. Our technicians use appropriate NIST-traceable test weights to evaluate critical performance characteristics including accuracy, repeatability, linearity, corner-load tolerances, and reduced span at or near full capacity.

The touchscreen, FACT internal adjustment system, weighing pan, leveling system, display, controls, and other installed features are also inspected and tested for proper operation.

Each refurbished MS3002TS includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation Considerations

Precision balances are sensitive measuring instruments and should be carefully packaged and handled during transportation. The MS3002TS is securely prepared for shipment to protect its MonoBloc weighing system, weighing pan, touchscreen, and other components.

Once installed, the balance should be positioned on a rigid, level, vibration-resistant work surface in an area with reasonably stable temperature and minimal air movement. The LevelControl system can then assist with proper leveling before the balance is placed into service.

Allowing the instrument to acclimate to its laboratory environment before final calibration and routine use can help improve weighing consistency.

For laboratories performing critical or regulated measurements, installation should be followed by appropriate calibration, verification, or qualification procedures according to the laboratory's quality system.

Related Laboratory Equipment

American Instrument Exchange maintains an extensive inventory of used and refurbished laboratory balances, including analytical balances, semi-micro balances, microbalances, and precision balances for applications ranging from routine sample preparation to high-resolution quantitative analysis.

Labs developing complete analytical or sample-preparation workflows can also source centrifuges, water baths, incubators, laboratory refrigerators, laboratory freezers, and other refurbished laboratory equipment from American Instrument Exchange.

Mettler Toledo MS3002TS Precision Balance FAQs

What is the maximum capacity of the Mettler Toledo MS3002TS?

The MS3002TS has a maximum weighing capacity of 3.2 kg, or 3,200 g, making it suitable for routine samples, reagents, containers, formulation ingredients, and general laboratory weighing.

What is the readability of the MS3002TS?

The Mettler Toledo MS3002TS provides 10 mg, or 0.01 g, readability across its 3.2 kg weighing range.

What is the typical repeatability of the MS3002TS?

Mettler Toledo specifies typical repeatability of approximately 7 mg, with a repeatability limit value of 10 mg.

What is the typical USP minimum weight of the MS3002TS?

Mettler Toledo specifies a typical USP minimum sample weight of approximately 14 g under specified conditions. Actual minimum weight should be established according to installed performance, environmental conditions, measurement uncertainty, and the laboratory's applicable quality procedures.

What is MiniWeigh on the Mettler Toledo MS3002TS?

MiniWeigh is designed to help users determine whether the material currently being weighed meets an established minimum sample weight. This can be particularly useful for laboratories where measurement uncertainty and minimum-weight requirements are important considerations.

Does the MS3002TS have automatic internal calibration?

Yes. The MS3002TS incorporates FACT automatic internal adjustment, helping maintain weighing performance as environmental conditions change. American Instrument Exchange also calibrates refurbished balances with NIST-traceable weights as part of its testing process.

Can the MS3002TS touchscreen be used while wearing gloves?

Yes. The large 7-inch touchscreen is designed for operation while wearing common laboratory gloves, including cotton, silicone, and rubber gloves.

Does the MS3002TS connect to computers and laboratory peripherals?

Yes. The MS3002TS provides USB-A, USB-B, Ethernet/LAN, and RS232 connectivity, with optional Bluetooth capability. This allows connection to compatible computers, printers, barcode readers, and other peripherals.

Does the MS3002TS require a draft shield?

For most routine applications, the 10 mg MS3002TS does not require the enclosed draft shield typically used with analytical and microbalances. However, laboratories working in areas with significant air movement or performing particularly demanding measurements may benefit from additional draft protection.

Why purchase a refurbished Mettler Toledo MS3002TS?

A refurbished MS3002TS provides laboratories with Mettler Toledo MonoBloc weighing technology, FACT automatic internal adjustment, a large touchscreen, 3.2 kg capacity, and 0.01 g readability without the acquisition cost associated with comparable new equipment. American Instrument Exchange tests, calibrates, cleans, and refurbishes each balance before shipment and provides a 90-day warranty.

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.