Mettler Toledo Precision Balance MS32001L/A03
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Mettler Toledo MS32001L/A03 Precision Balance is a rugged, high-capacity laboratory balance designed for accurate weighing of large samples, containers, formulation batches, and bulk materials. With a maximum capacity of 32.2 kg and 0.1 g readability, the MS32001L/A03 provides a practical combination of high capacity, reliable precision, and durable construction for pharmaceutical, chemical, food and beverage, manufacturing, quality-control, and research laboratories.
Available used and refurbished from American Instrument Exchange, the Mettler Toledo MS32001L/A03 provides laboratories with proven Mettler Toledo weighing technology at a significantly lower acquisition cost than purchasing comparable new equipment. Each balance is inspected, cleaned, calibrated, and tested for weighing accuracy and repeatability before shipment and includes a 90-day warranty from American Instrument Exchange.
32.2 kg / 32,200 g maximum weighing capacity
100 mg / 0.1 g readability
Typical repeatability of 0.07 g
Typical USP minimum weight of approximately 140 g
FACT automatic internal adjustment
Proven MonoBloc weighing cell
Overload protection greater than 100 kg
Large 245 × 351 mm stainless steel weighing pan
Chemical-resistant die-cast aluminum housing
Approximately 2-second settling time
High-contrast backlit display with large digits
Three programmable SmartKeys for frequently used applications
LevelControl supports correct balance setup
Integrated USB and RS232 connectivity
Optional Bluetooth connectivity
Multiple built-in weighing applications
Used, refurbished, calibrated, and tested by American Instrument Exchange
90-day warranty included
The Mettler Toledo MS32001L/A03 is designed for laboratories that need substantially greater weighing capacity than a conventional analytical or benchtop precision balance can provide. Its 32.2 kg capacity and 0.1 g readability allow users to weigh heavy samples, large vessels, bulk materials, and kilogram-scale formulations while retaining laboratory-grade measurement resolution.
At the heart of the MS32001L/A03 is Mettler Toledo's proven MonoBloc weighing cell, designed to provide fast and repeatable measurements even under demanding weighing conditions. The weighing system is protected by unusually strong overload protection rated at more than 100 kg, helping safeguard the load cell when heavy containers or materials are placed on the balance.
The full metal housing provides additional durability and chemical resistance, making the MS32001L/A03 particularly well suited for active laboratory and production-support environments.
Mettler Toledo also incorporates FACT automatic internal adjustment, programmable SmartKeys, multiple built-in weighing applications, and electronic connectivity. Together, these features make the MS32001L/A03 more than a simple high-capacity scale—it is a laboratory precision balance designed for repeatable quantitative workflows.
The Mettler Toledo MS32001L/A03 is particularly well suited for weighing procedures involving larger samples, heavy containers, bulk materials, and kilogram-scale quantities.
Pharmaceutical and biotechnology laboratories can use the balance for formulation, media and buffer preparation, bulk reagent preparation, ingredient weighing, scale-up work, sample preparation, and quality-control procedures. Its 32.2 kg capacity allows materials to be weighed directly into larger bottles, vessels, carboys, and preparation containers.
Chemical laboratories can use the MS32001L/A03 for compound preparation, formulation development, percentage weighing, batching, totaling, check weighing, and general quantitative work.
Food and beverage, cosmetics, materials science, industrial, and manufacturing laboratories may also benefit from the balance when formulations or samples involve kilogram-scale quantities but still require reliable 0.1 g resolution.
Built-in applications including counting, percent weighing, dynamic weighing, formulation, totaling, check weighing, and factor weighing further expand its usefulness across routine laboratory and production-support workflows.
The MS32001L/A03 is a strong choice for pharmaceutical, biotechnology, chemical, food and beverage, cosmetics, materials science, manufacturing, industrial research, academic, and quality-control laboratories.
It is especially valuable in facilities where conventional laboratory work overlaps with pilot-scale, manufacturing-support, or bulk formulation procedures.
The combination of a large stainless steel weighing pan, 32.2 kg capacity, chemical-resistant metal housing, and substantial overload protection also makes the MS32001L/A03 a good fit for demanding laboratory environments where balances are used frequently and may be exposed to heavier containers and samples.
The Mettler Toledo MS32001L/A03 provides 0.1 g readability across a 32.2 kg weighing range, allowing laboratories to measure relatively small changes in mass while working with samples and containers weighing tens of kilograms.
Mettler Toledo specifies typical repeatability of approximately 0.07 g, typical linearity deviation of 0.06 g, and linearity of ±0.3 g. The balance has a settling time of approximately 2 seconds.
This combination of capacity and resolution makes the MS32001L/A03 particularly useful when container tare weight is significant. A laboratory can place a heavy bottle, carboy, vessel, or other container directly on the weighing pan, tare its weight, and retain substantial usable capacity for the material being added.
For laboratories comparing analytical, semi-micro, micro, and precision balances, the MS32001L/A03 prioritizes high capacity, durability, easy sample handling, and reliable gram-to-kilogram weighing rather than extreme sub-milligram resolution.
Maximum capacity and readability alone do not determine whether a balance is appropriate for a particular quantitative procedure. Laboratories working under USP requirements should also consider the minimum sample weight necessary to achieve the required measurement uncertainty.
Mettler Toledo specifies a typical USP minimum weight of approximately 140 g for the MS32001L/A03 under specified conditions. The manufacturer also specifies a typical minimum weight of approximately 14 g at U=1%, k=2.
Actual minimum weight can vary according to balance condition, installation, environmental influences, measurement uncertainty requirements, and laboratory procedures.
For regulated or validated applications, laboratories should establish minimum weight according to their own qualification procedures and applicable quality requirements rather than relying exclusively on published typical values.
For applications involving substantially smaller samples, an analytical, semi-micro, micro, or lower-capacity precision balance may provide a more appropriate combination of readability and minimum weight.
One of the distinguishing characteristics of the MS32001L/A03 is its ability to tolerate the demanding physical conditions associated with high-capacity laboratory weighing.
Mettler Toledo specifies overload protection greater than 100 kg, providing substantial protection for the MonoBloc weighing cell if an excessively heavy sample or container is accidentally placed on the balance.
This is particularly valuable in laboratories where large vessels, bulk materials, and heavy containers are routinely handled around the weighing station. While overload protection should never be treated as additional usable weighing capacity, it provides an important safeguard against accidental damage.
The 245 × 351 mm stainless steel weighing pan also provides ample room for bulky items. A groove incorporated into the weighing surface helps stabilize cylindrical objects and reduces the tendency of bottles or other round items to roll across the pan.
Although a 0.1 g precision balance is considerably less sensitive to minor environmental disturbances than a microbalance or analytical balance, vibration, temperature changes, unstable work surfaces, strong airflow, and improper leveling can still affect measurement performance.
The MS32001L/A03 incorporates LevelControl to help users establish proper balance setup and recognize when leveling requires attention.
For best performance, the balance should be installed on a rigid, stable, level surface capable of safely supporting both the balance and the anticipated sample load. Placement near centrifuges, shakers, compressors, frequently opened doors, or other significant sources of vibration should be avoided whenever possible.
The chemical-resistant metal housing and stainless steel pan also make routine cleaning easier, an important consideration when the balance is used for formulation or reagent preparation where powders and liquids may be handled directly around the weighing surface.
The MS32001L/A03 incorporates Mettler Toledo's FACT automatic internal adjustment, allowing the balance to perform internal adjustment as laboratory conditions change.
FACT can initiate adjustment based on time and temperature conditions, reducing reliance on manually initiated adjustment procedures and helping maintain consistent weighing performance throughout the working day.
Laboratories operating under GLP, GMP, USP, or internal quality systems may still require scheduled performance verification using appropriate traceable test weights and documented calibration procedures. Internal adjustment should therefore be considered one component of a complete balance quality-control program rather than a replacement for laboratory-specific calibration or qualification requirements.
The MS32001L/A03 includes USB and RS232 interfaces, allowing the balance to communicate with compatible printers, barcode readers, computers, and other peripheral devices.
Electronic data transfer can reduce the need to manually transcribe weighing results, potentially improving both workflow efficiency and record accuracy.
Three programmable SmartKeys give operators rapid access to frequently used applications and functions. The balance also provides built-in applications for weighing, counting, percent weighing, dynamic weighing, check weighing, formulation, totaling, factor weighing, and other routine procedures.
These capabilities make the MS32001L/A03 useful not only for individual measurements but also for laboratories performing repetitive or standardized weighing procedures throughout the working day.
| Specification | Mettler Toledo MS32001L/A03 |
|---|---|
| Balance Type | High-Capacity Precision Balance |
| Maximum Capacity | 32.2 kg / 32,200 g |
| Readability | 100 mg / 0.1 g |
| Typical Repeatability | 0.07 g |
| Typical USP Minimum Weight | 140 g |
| Typical Minimum Weight (U=1%, k=2) | 14 g |
| Linearity | ±0.3 g |
| Typical Linearity Deviation | 0.06 g |
| Settling Time | Approx. 2 seconds |
| Adjustment | Internal / automatic FACT |
| Weighing Pan | 245 × 351 mm |
| Display | High-contrast backlit LCD |
| Overall Dimensions | 363 mm W × 346 mm D × 118 mm H |
| Weighing Cell | MonoBloc |
| Overload Protection | Greater than 100 kg |
| Housing | Chemical-resistant die-cast aluminum |
| Connectivity | USB-A and RS232 |
| Wireless Connectivity | Optional Bluetooth |
| SmartKeys | 3 programmable |
| Legal for Trade | Yes / approved configuration |
A high-capacity precision balance and analytical balance are designed for fundamentally different weighing requirements. The appropriate choice depends on the smallest quantity that must be measured accurately, maximum combined sample and container weight, required measurement uncertainty, and laboratory workflow.
Analytical balances commonly provide 0.1 mg readability and are designed for much smaller samples requiring extremely fine resolution. Their capacities, however, are generally measured in hundreds of grams rather than tens of kilograms.
The MS32001L/A03 takes the opposite approach. With 32.2 kg capacity and 0.1 g readability, it sacrifices sub-milligram sensitivity in exchange for dramatically greater capacity, a large accessible weighing pan, and robust construction.
For laboratories preparing large formulations, buffers, media, bulk reagents, or other kilogram-scale quantities, the MS32001L/A03 can therefore be considerably more practical than an analytical balance.
Laboratories performing both bulk preparation and small-sample analytical work may benefit from maintaining both types of balances so that each procedure can be performed on an instrument appropriately matched to the required capacity and resolution.
Every used Mettler Toledo MS32001L/A03 sold by American Instrument Exchange is inspected, cleaned, refurbished as necessary, calibrated, and tested before shipment.
Because weighing performance is the primary function of a precision balance, testing goes beyond simply confirming that the instrument powers on and displays a stable weight. Our technicians evaluate balance operation using appropriate test weights and check critical performance characteristics including accuracy, repeatability, linearity, corner-load tolerances, and reduced span at or near full capacity.
The display, FACT internal adjustment system, weighing platform, leveling components, SmartKeys, controls, and other installed features are also inspected and tested for proper operation.
Each refurbished MS32001L/A03 includes a 90-day warranty from American Instrument Exchange.
The MS32001L/A03 is a precision measuring instrument and should be carefully packaged and handled during transportation. American Instrument Exchange securely prepares the balance for shipment to protect the MonoBloc weighing system, weighing platform, display, and other components.
Because the balance can accommodate loads up to 32.2 kg, the installation surface deserves particular consideration. The bench or table should be rigid, level, vibration-resistant, and capable of safely supporting the balance plus the anticipated sample and container weight.
Once installed, the balance should be allowed to acclimate to its laboratory environment before final adjustment and use. For laboratories performing critical or regulated measurements, installation should be followed by appropriate calibration, verification, or qualification according to the laboratory's quality system.
American Instrument Exchange maintains an extensive inventory of used and refurbished laboratory balances, including analytical balances, semi-micro balances, microbalances, and precision balances for applications ranging from routine sample preparation to high-resolution quantitative analysis.
Labs developing complete analytical or sample-preparation workflows can also source centrifuges, water baths, incubators, laboratory refrigerators, laboratory freezers, and other refurbished laboratory equipment from American Instrument Exchange.
The MS32001L/A03 has a maximum weighing capacity of 32.2 kg, or 32,200 g, making it suitable for large containers, bulk materials, formulation batches, and other high-capacity laboratory weighing applications.
The Mettler Toledo MS32001L/A03 provides 100 mg, or 0.1 g, readability across its weighing range.
Mettler Toledo specifies typical repeatability of approximately 0.07 g under appropriate operating conditions.
Mettler Toledo specifies a typical USP minimum weight of approximately 140 g under specified conditions. Actual minimum weight should be established according to installed balance performance, environmental conditions, measurement uncertainty, and applicable laboratory procedures.
Mettler Toledo specifies overload protection greater than 100 kg. This helps protect the weighing cell against accidental overloads when heavy containers or materials are being handled. The overload rating does not increase the balance's 32.2 kg maximum usable weighing capacity.
Yes. The balance incorporates Mettler Toledo's FACT automatic internal adjustment, which helps maintain weighing performance as temperature and operating conditions change. Regulated laboratories may still require documented external verification, calibration, and qualification procedures.
The balance supports a variety of routine applications including standard weighing, counting, percent weighing, dynamic weighing, check weighing, formulation, totaling, and factor weighing. Programmable SmartKeys provide rapid ac
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.