Baker SterilGARD III SG404 Biosafety Cabinet – Refurbished
The Baker SterilGARD III SG404 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring HEPA-filtered airflow and contamination control. Commonly used for cell culture, microbiology, pharmaceutical, and research laboratory applications, this refurbished Baker biosafety cabinet offers reliable containment performance for laboratories requiring clean working conditions and sterile sample handling.
At American Instrument Exchange, each biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.
Baker SterilGARD III SG404 key Features
· Class II Type A2 biosafety cabinet
· 90-day warranty included from American Instrument Exchange
· Includes stand and new HEPA filters
· Designed for personnel, product, and environmental protection
· Suitable for cell culture and microbiology workflows
· Refurbished and tested by American Instrument Exchange
· HEPA-filtered airflow for contamination control
· Ideal for research, pharmaceutical, and clinical laboratories
Baker SterilGARD III SG404 Overview
The Baker SterilGARD III SG404 is a Class II Type A2 biosafety cabinet designed for laboratory environments requiring contamination control, sterile airflow, and operator protection. Baker biosafety cabinets are widely used throughout research, pharmaceutical, biotechnology, clinical, and academic laboratories because of their airflow stability, ergonomic workspace design, and long-standing reputation in laboratory containment equipment.
This cabinet configuration is commonly used for sterile laboratory workflows involving biological samples, tissue culture procedures, microbiology applications, and other laboratory tasks requiring both operator protection and product protection. The cabinet’s airflow system is designed to help maintain clean working conditions while minimizing particulate contamination within the work area.
Features may include a stainless steel work surface, integrated lighting, ergonomic sash design, airflow monitoring systems, and low-noise blower operation depending on the specific configuration of the unit.
Baker SterilGARD III SG404 Common Applications
The Baker SterilGARD III SG404 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow and contamination control. Typical applications include cell culture workflows, microbiology procedures, tissue culture applications, pharmaceutical research, sterile sample preparation, and other biological laboratory procedures where product protection and personnel protection are important.
This biosafety cabinet may also be appropriate for biotechnology laboratories, hospital laboratories, research universities, clinical testing facilities, and life science laboratories performing contamination-sensitive workflows or biological research applications.
Baker SterilGARD III SG404 Ideal Laboratory Environments
This biosafety cabinet may be suitable for a wide range of laboratory environments including biotechnology laboratories, academic research facilities, pharmaceutical production environments, hospital laboratories, government research institutions, and cleanroom applications.
Its containment-focused airflow design makes it appropriate for laboratories requiring controlled working conditions for biological procedures, sterile workflows, and sensitive laboratory applications involving contamination control.
Baker SterilGARD III SG404 Key Specifications
|
Specification
|
Details
|
|
Manufacturer
|
Baker
|
|
Model
|
SterilGARD III SG404
|
|
Cabinet Class
|
Class II Type A2
|
|
Exterior Dimensions
|
53.75"W x 30.5"D x 61.75"H (not including stand)
|
|
Interior Worksurface Dimensions
|
46"W x 24.5"D x 27.5"H
|
|
Electrical Requirements
|
115V, 60Hz, 15amp
|
|
Weight
|
Approximately 585lbs.
|
|
Included Accessories
|
Stand and new HEPA filters
|
|
Warranty
|
90-day warranty
|
|
|
Baker SterilGARD III SG404 Refurbishment and Testing
American Instrument Exchange has extensive experience refurbishing used biosafety cabinets for laboratory and cleanroom environments.
Each biosafety cabinet is inspected by our technicians to verify proper blower operation, control functionality, airflow performance, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.
Testing procedures include major elements associated with biosafety cabinet certification to help support certification readiness upon installation at your facility. Final certification should be completed by qualified field technicians after installation in accordance with laboratory and facility requirements.
Certification Readiness
Biosafety cabinets should be certified by qualified field technicians after installation and before laboratory use.
American Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, electrical requirements, airflow requirements, and certification standards prior to installation.
Certification services are available through our affiliate company, AIE Laboratory Services.
Certification requirements may vary depending on laboratory protocols, facility standards, and application requirements.
Shipping and Installation Considerations
Biosafety cabinets are oversized laboratory instruments that may require special handling during transportation, delivery, and installation. Buyers should confirm laboratory access dimensions, doorway clearances, electrical compatibility, and final cabinet placement before shipment.
Depending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.
Frequently Asked Questions
What are some of the features that make the Baker SterilGard SG404 a good investment?
Because of the improvements in efficiency annual operating costs for the SG404 can be up to 70% lower than compared to the Baker SG403 models.
A lot of this reduction can be attributed to the new StediFLOW variable frequency drive motor, which can accommodate increases in pressure drops of up to 300% across the filter with almost no reduction in total air delivery. One of our favorite features is the fold up front panel that allows for frontloading filters.
For most biosafety cabinets, including older Baker units, removing the front panel is a time and labor-intensive activity. With the SG404, however, the hinged front panel swings up, similar to the hood of a car, allowing for quicker and easier HEPA filter replacement.
This sounds like a small improvement, but if you work with biosafety cabinets as frequently as we do you will quickly begin to appreciate how great this design is.
Are the Baker Sterilgard SG404 units as durable as the older SG400 models?
Time will tell, although all indications are that these units will have some serious longevity. As of this writing we still see some Baker SG400 models in the field – every now and then our certifiers will come across a unit that is older than they are.
Will the Sterilgard 404s last this long? They are certainly quality built, as are all Baker products, with quality materials and a good design. We’re looking forward to working with these units for many years to come.
Why do you install new HEPA filters in the Baker SG404 before shipping to customers?
New filters for a Baker SterilGard SG404, plus the cost of installation, can total anywhere from $2,000 to $3,500 or more, depending on your location and what your certifier charges for installation. We install new HEPA filters in every biosafety cabinet and clean bench prior to shipment. If you’re purchasing a used biosafety cabinet without filters, there’s no way to know for sure that it works properly.
If you’re buying a used biosafety cabinet with old filters, you may not be able to determine the age of the filters or safe operating time remaining, plus there are concerns of contamination. Installing new filters is the best way for us to guarantee that each biosafety cabinet works to specification and completely decontaminated.