Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

VWR HC-MFP-20 Laboratory Freezer

Fully Tested & Warrantied*
Brand : VWR
Product Code : SKU 2568DD FREEZER

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

VWR HC-MFP-20 Laboratory Freezer – 20 Cu. Ft. Manual Defrost

The VWR HC-MFP-20 Laboratory Freezer is a 20 cu. ft. upright manual-defrost freezer designed for reliable frozen storage of laboratory reagents, biological materials, research samples, enzymes, analytical standards, and other temperature-sensitive inventory. With an adjustable operating range of -15°C to -25°C, the HC-MFP-20 is well suited for laboratories requiring dependable approximately -20°C frozen storage.

Designed as part of the VWR Standard Series, the HC-MFP-20 combines forced-draft air circulation, microprocessor temperature control, dual temperature probes, audible and visual temperature alarms, remote alarm contacts, probe access, and a keyed door lock in a cost-effective full-size laboratory freezer.

The unit also uses R290 natural hydrocarbon refrigerant, providing an environmentally conscious refrigeration platform while maintaining the performance required for scientific and industrial cold-storage applications.

This used VWR HC-MFP-20 freezer is refurbished and tested by American Instrument Exchange prior to shipment and includes a 90-day warranty from AIE.

Key Features

  • 20 cu. ft. laboratory freezer capacity

  • Adjustable temperature range from -15°C to -25°C

  • Ideal for approximately -20°C laboratory storage

  • Manual-defrost refrigeration system

  • Forced-draft air circulation

  • R290 natural hydrocarbon refrigerant

  • Microprocessor temperature controller

  • Digital temperature display switchable between °C and °F

  • Audible and visual high- and low-temperature alarms

  • Remote alarm contacts for external monitoring

  • Two temperature probes: one in chamber air and one in a sample bottle

  • Six fixed shelves

  • 3/4" rear probe access port

  • Keyed door lock

  • Right-hinged solid door

  • High-density urethane foam insulation

  • White powder-coated steel exterior

  • ETL and C-ETL listed and certified to UL471

  • 115 V, 60 Hz operation

  • Refurbished and tested by American Instrument Exchange

  • 90-day AIE warranty included

Overview

The VWR HC-MFP-20 is designed for laboratories that need substantial -20°C-class frozen storage capacity without moving into the significantly colder operating range, higher acquisition cost, and greater energy requirements associated with an ultra-low temperature freezer.

Its 20 cu. ft. chamber provides enough capacity for a significant inventory of samples, reagents, enzymes, standards, and other frozen laboratory materials while maintaining the convenient access of a single-door upright cabinet.

Temperature is controlled by a microprocessor-based controller with a digital display, allowing users to monitor chamber temperature directly from the front of the freezer. The display can be switched between Celsius and Fahrenheit according to laboratory preference.

The HC-MFP-20 also incorporates forced-draft circulation, helping distribute cold air throughout the storage chamber. This is particularly important in a full-size laboratory freezer, where stored materials may be distributed across multiple shelves and different areas of the cabinet.

Six fixed shelves provide clearly defined storage areas for organizing samples and inventory. Laboratories can dedicate individual shelves to specific projects, departments, researchers, sample types, or materials to simplify retrieval and reduce unnecessary door-open time.

For biotechnology companies, research institutions, pharmaceutical facilities, and other laboratories replacing an aging -20°C freezer, a refurbished VWR HC-MFP-20 can provide a cost-effective alternative to purchasing comparable new cold-storage equipment.

Common Applications

The VWR HC-MFP-20 is designed for frozen storage applications requiring temperatures between -15°C and -25°C. Typical materials may include laboratory reagents, enzymes, biological specimens, research samples, analytical standards, diagnostic materials, controls, research compounds, and other products specified for approximately -20°C storage.

Its combination of a 20 cu. ft. chamber and six shelves makes the freezer appropriate for both general-purpose laboratory cold storage and organized departmental inventories.

Applications may include molecular biology, biotechnology research, pharmaceutical development, biomedical research, analytical chemistry, clinical research, diagnostic testing, industrial quality control, and academic research.

Researchers should always follow the specified storage requirements for individual samples, reagents, and products rather than assuming all frozen laboratory materials are appropriate for -20°C storage.

Ideal Laboratory Types

The VWR HC-MFP-20 is well suited for biotechnology companies, pharmaceutical laboratories, universities, academic research institutions, molecular biology laboratories, biomedical research facilities, hospitals, clinical research organizations, analytical laboratories, diagnostic facilities, and industrial quality-control laboratories.

Its 20 cu. ft. capacity makes it particularly useful for laboratories that have outgrown compact or undercounter freezers but do not require ultra-low temperature storage.

The HC-MFP-20 can serve as a primary -20°C laboratory freezer or as supplemental frozen storage in larger facilities with multiple cold-storage systems.

Temperature Recovery & Uniformity

The VWR HC-MFP-20 incorporates forced-draft air circulation to help distribute cooled air throughout its 20 cu. ft. chamber. Active circulation is especially useful in a full-height cabinet containing multiple shelves and a substantial inventory of frozen materials.

The freezer's microprocessor control system continuously monitors chamber conditions, while its two-probe configuration provides temperature measurement in both the chamber air and a sample bottle.

This combination provides a more useful picture of freezer performance than relying exclusively on an air-temperature measurement. Air temperature can respond rapidly to a door opening, while a probe located in a sample bottle can provide a buffered measurement that better represents changes affecting stored materials.

The freezer is also equipped with audible and visual high- and low-temperature alarms, providing an additional layer of protection if chamber conditions move outside acceptable limits.

Temperature recovery following a door opening will vary according to ambient conditions, freezer loading, door-open duration, sample mass, ventilation, and refrigeration-system condition.

Keeping the six shelves organized so materials can be retrieved quickly can help minimize door-open time and reduce unnecessary temperature disturbances.

Sample Storage Recommendations

The HC-MFP-20's six fixed shelves provide convenient separation of frozen inventory. Laboratories can assign shelves according to research group, project, sample type, reagent class, or frequency of access.

Frequently used materials should be stored where they can be located and retrieved quickly. Less frequently accessed inventory can be positioned elsewhere in the chamber to reduce unnecessary searching with the freezer door open.

Stored materials should not be arranged in a manner that interferes with normal air circulation. Maintaining appropriate spacing around inventory allows the freezer's forced-draft system to circulate cooled air throughout the chamber.

Because this is a manual-defrost freezer, frost and ice accumulation should also be monitored. Periodic defrosting is necessary to prevent excessive ice buildup from reducing usable storage space or affecting normal freezer operation.

High-value or irreplaceable samples should be supported by appropriate laboratory procedures, including independent temperature monitoring where warranted, documented alarm-response procedures, backup frozen-storage capacity, and contingency plans for equipment or power failure.

The HC-MFP-20 should not be used as a substitute for an ultra-low temperature freezer when samples require approximately -80°C storage.

Key Specifications

Specification VWR HC-MFP-20
Equipment Type Laboratory Freezer
Manufacturer VWR
Model HC-MFP-20
Series VWR Standard Series
Capacity 20 cu. ft.
Temperature Range -15°C to -25°C
Defrost Manual
Air Circulation Forced draft
Refrigerant R290 natural hydrocarbon
Temperature Controller Microprocessor
Display Digital, °C/°F switchable
Temperature Probes 2 – chamber air and sample bottle
Temperature Alarms Audible and visual high/low
Remote Alarm Contacts Yes
Shelves 6 fixed
Door Solid, right hinged
Door Lock Keyed
Probe Access Port 3/4" rear wall port
Exterior Material White powder-coated steel
Insulation High-density urethane foam
Interior Lighting No
Electrical 115 V, 60 Hz
Rated Amperage 5.5 A
Plug NEMA 5-15
Exterior Dimensions 30.75"W × 29"D × 74.625"H
Interior Dimensions 25.875"W × 21.75"D
Door Swing 28.75"
Total Open Depth 57.75"
Product Weight 250 lb.
Shipping Weight 225 lb.
Certifications ETL / C-ETL; UL471
Recommended Ambient Conditions +18°C to +26°C (+65°F to +78°F), <70% RH
Condition Used / Refurbished
AIE Warranty 90 days

Energy Efficiency & Operating Costs

The VWR HC-MFP-20 uses R290 natural hydrocarbon refrigerant, which VWR selected as part of the Standard Series design for environmental and energy-efficiency considerations.

For laboratories requiring approximately -20°C storage, a conventional laboratory freezer such as the HC-MFP-20 can also be a more appropriate solution than operating an ultra-low temperature freezer for materials that do not require -80°C conditions.

Installation and operating practices have a significant effect on refrigeration performance. VWR specifies that the HC-MFP-20 requires 4 inches of clearance around the back and sides of the cabinet for proper ventilation.

This clearance is important because heat generated by the refrigeration system must be able to dissipate into the surrounding environment. Inadequate ventilation can contribute to temperature-maintenance problems, overheating, increased compressor stress, and potential equipment failure.

Laboratories can further reduce unnecessary refrigeration demand by minimizing prolonged door openings, keeping the freezer organized, maintaining a good door seal, and performing periodic manual defrosting before severe ice buildup develops.

Actual energy consumption will depend on ambient temperature, freezer setpoint, sample loading, door-opening frequency, ventilation, frost accumulation, and refrigeration-system condition.

Refurbishment & Testing

This VWR HC-MFP-20 laboratory freezer is supplied used and refurbished by American Instrument Exchange.

Before shipment, our technicians inspect, clean, and test the freezer to verify proper operation. Temperature-controlled laboratory equipment is tested using NIST-traceable temperature probes and data logging equipment as appropriate to evaluate temperature performance.

The HC-MFP-20 is operated under frozen-storage conditions to verify its ability to reach and maintain temperatures within its specified operating range. Temperature performance is monitored over time rather than relying solely on the freezer's front-panel display.

Our technicians also inspect the refrigeration system, microprocessor controller, digital display, temperature alarms, remote alarm functionality as applicable, temperature probes, door, hinges, keyed lock, gasket, shelves, probe access port, electrical components, and cabinet.

The freezer is checked for excessive frost or ice accumulation and manually defrosted as necessary during preparation. The interior chamber, shelves, door surfaces, and exterior cabinet are thoroughly cleaned before the unit is released for shipment.

Worn or defective components are repaired or replaced as necessary during the refurbishment process.

Customers with specific temperature-testing, documentation, or application requirements are encouraged to discuss those requirements with American Instrument Exchange before shipment. When practical, our technicians can accommodate application-specific testing requests during the refurbishment process.

This refurbished VWR HC-MFP-20 includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation

The VWR HC-MFP-20 measures approximately 30.75"W × 29"D × 74.625"H, making it a full-height upright laboratory freezer. Customers should verify delivery-path clearance through loading docks, doorways, hallways, elevators, and laboratory entrances before shipment.

The freezer requires 115 V, 60 Hz electrical service, draws 5.5 A, and uses a NEMA 5-15 plug.

Installation planning should account for more than cabinet dimensions alone. VWR specifies 4 inches of ventilation clearance around the back and sides of the freezer. This clearance should not be eliminated by pushing the cabinet tightly against walls, adjacent equipment, or laboratory casework.

The door requires approximately 28.75 inches of swing clearance, and total cabinet depth with the door fully open is approximately 57.75 inches.

After transportation and placement, the freezer should be allowed to stabilize as appropriate before being brought to operating temperature. Laboratories should verify satisfactory temperature performance before transferring valuable frozen inventory into the chamber.

American Instrument Exchange can arrange freight transportation throughout the United States and internationally. Customers requiring liftgate service, inside delivery, rigging, or specialized handling should discuss those requirements with AIE before shipment.

Related Laboratory Equipment

Laboratories requiring additional frozen storage can browse American Instrument Exchange's selection of laboratory freezers, including manual-defrost, automatic-defrost, upright, undercounter, and specialty laboratory freezers from VWR, Thermo Scientific, Fisher Scientific, Panasonic, PHCbi, and other major manufacturers.

For biological samples requiring approximately -80°C storage rather than conventional -20°C conditions, AIE maintains a large inventory of refurbished ultra-low temperature freezers.

Materials requiring refrigerated rather than frozen storage can be accommodated by our selection of laboratory refrigerators, including solid-door, glass-door, chromatography, and undercounter models.

American Instrument Exchange also offers refurbished centrifuges, CO₂ incubators, and biosafety cabinets for laboratories replacing or expanding essential research equipment.

Frequently Asked Questions

What is the temperature range of the VWR HC-MFP-20?

The VWR HC-MFP-20 has an adjustable temperature range of -15°C to -25°C, making it suitable for many laboratory materials requiring approximately -20°C frozen storage.

How large is the VWR HC-MFP-20?

The freezer provides 20 cu. ft. of storage capacity and includes six fixed shelves.

Its exterior dimensions are approximately 30.75"W × 29"D × 74.625"H.

Is the VWR HC-MFP-20 a manual-defrost freezer?

Yes. The HC-MFP-20 uses a manual-defrost refrigeration system. VWR recommends periodic defrosting to prevent severe ice buildup.

Manual-defrost freezers are commonly used in scientific environments because they avoid the automatic warming cycles associated with conventional automatic-defrost systems.

What refrigerant does the HC-MFP-20 use?

The HC-MFP-20 uses R290 natural hydrocarbon refrigerant.

Does the VWR HC-MFP-20 have temperature alarms?

Yes. The freezer includes audible and visual high- and low-temperature alarms to alert laboratory personnel to abnormal temperature conditions.

Can the HC-MFP-20 connect to an external alarm system?

Yes. The freezer includes remote alarm contacts, allowing it to interface with compatible external monitoring or building alarm systems.

Why does the HC-MFP-20 use two temperature probes?

The freezer incorporates two probes: one measuring chamber air and another located in a sample bottle.

The air probe responds more quickly to changes in chamber conditions, while the sample-bottle probe provides a buffered measurement that can more closely represent temperature changes affecting stored materials.

Does the HC-MFP-20 have a probe access port?

Yes. A 3/4-inch rear wall access port allows compatible independent monitoring probes or other approved instrumentation to enter the chamber without routing wiring through the door gasket.

Is the VWR HC-MFP-20 an ultra-low temperature freezer?

No. The HC-MFP-20 is a conventional laboratory freezer with a range of -15°C to -25°C. Ultra-low temperature freezers are designed for substantially colder storage, commonly around -80°C.

How much ventilation clearance does the HC-MFP-20 require?

VWR specifies 4 inches of clearance around the back and sides of the freezer for proper ventilation.

Adequate clearance is important for heat dissipation and reliable refrigeration-system operation.

What electrical service does the VWR HC-MFP-20 require?

The HC-MFP-20 operates on 115 V, 60 Hz power, is rated at 5.5 A, and uses a NEMA 5-15 plug.

How does American Instrument Exchange test a refurbished VWR HC-MFP-20?

American Instrument Exchange operates and tests refurbished laboratory freezers before shipment. NIST-traceable temperature probes and data logging equipment are used as appropriate to evaluate temperature performance over time.

The refrigeration system, controller, alarms, probes, electrical components, door hardware, gasket, shelves, and cabinet are also inspected for proper operation and physical condition.

Does this refurbished VWR HC-MFP-20 include a warranty?

Yes. This used and refurbished VWR HC-MFP-20 laboratory freezer includes a 90-day warranty from American Instrument Exchange unless otherwise noted.

Testing Procedures for Used and Refurbished Laboratory Freezers

Cold Storage Reliability from American Instrument Exchange

At American Instrument Exchange, every used and refurbished laboratory freezer we offer undergoes a comprehensive multi-point testing protocol to ensure optimal performance, temperature stability, and long-term reliability. Our rigorous testing procedures are designed to meet the demanding standards of biomedical, pharmaceutical, research, and clinical environments—so you can trust your freezer to protect your valuable samples and materials.

Why Testing Refurbished Laboratory Freezers Is Critical

Before any laboratory freezer is placed back into service, it must be carefully tested for:

  • Consistent temperature control and uniformity across internal zones
  • Compressor functionality and refrigeration system performance
  • Seal integrity and insulation efficiency to prevent temperature loss
  • Electrical safety and alarm system operation

Thorough testing minimizes the risk of temperature excursions, equipment failure, and product loss—especially for temperature-sensitive items like reagents, biological samples, and vaccines.

Our structured testing protocol ensures that all used and refurbished laboratory freezers meet or exceed manufacturer specifications and industry expectations.

Key Testing Procedures for Laboratory Freezers

1. Visual and Structural Inspection

  • Examine the exterior for dents, corrosion, or physical damage
  • Check door gaskets, hinges, and latches for wear and functionality
  • Inspect power cords, control panels, and internal compartments

2. Functional Startup and System Check

  • Power on the unit to verify startup sequence, control panel functionality, and display readability
  • Test programmable settings, alarms, and door-open sensors
  • Ensure proper door closure and sealing performance

3. Temperature Performance and Stability Testing

  • Test temperature sensors using certified thermometers or probes
  • Monitor chamber temperature at multiple points over extended run periods
  • Verify temperature uniformity and accuracy across common lab setpoints (e.g., -20°C, -30°C)

4. Compressor and Refrigeration System Evaluation

  • Test compressor startup, cycling behavior, and operating noise
  • Check condenser coils, evaporators, and fans for performance and cleanliness
  • Inspect for refrigerant leaks or pressure issues that may affect efficiency

5. Electrical Safety and Compliance Verification

  • Confirm proper grounding and insulation of all electrical components
  • Conduct safety testing to meet laboratory equipment electrical standards
  • Verify functionality of alarms for power loss, temperature excursions, and system faults

6. Final Quality Assurance and Runtime Validation

  • Conduct multi-day test cycle to confirm stable performance under continuous use
  • Record temperature data, alarm responses, and compressor cycling metrics
  • Complete final inspection and prepare detailed service documentation

Reliable Cold Storage, Backed by Testing Excellence

Each refurbished laboratory freezer from American Instrument Exchange is tested and certified for cold storage accuracy, safety, and performance. Whether upright, undercounter, flammable-material rated, or specialty-purpose, our lab freezers are restored to meet real-world research and clinical demands.

Trust American Instrument Exchange for dependable, tested, and warrantied laboratory refrigeration—ready to support your lab from day one.

Repair and Refurbishment Protocol for Used Laboratory Freezers
Certified Cold Storage Performance from American Instrument Exchange

At American Instrument Exchange, every used laboratory freezer we offer is subjected to a comprehensive repair and refurbishment protocol. Whether it’s a general-purpose lab freezer, flammable-material grade unit, or undercounter model, our goal is to restore each system to peak performance—ensuring consistent temperature control and reliable operation.

Why Choose a Refurbished Laboratory Freezer from American Instrument Exchange?

• Fully tested for cold storage accuracy and operational safety
• Backed by a warranty
• Cost-effective alternative to new refrigeration equipment
• Sustainably refurbished to reduce environmental impact
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every laboratory freezer from American Instrument Exchange follows a detailed, multi-stage process to ensure top-tier performance and reliability:

1. Initial Intake & Inspection

• Visual inspection for dents, corrosion, or structural damage
• Mechanical check of door hinges, gaskets, seals, and internal components
• Documentation of missing parts or areas requiring repair or replacement

2. Cleaning and Decontamination

• Internal and external cleaning using non-abrasive cleaners
• Decontamination/cleaning of all surfaces to remove biological or chemical residues
• Thorough cleaning of shelving, drawers, and removable interior parts

3. Mechanical and Electrical Repairs

• Replacement or repair of worn mechanical parts (door latches, seals, hinges, etc.)
• Inspection and restoration of control interfaces, thermostats, sensors, and displays
• Evaluation of wiring, relays, fuses, and power supply components for safety and integrity

4. Refrigeration System and Compressor Evaluation

• Testing of compressor function, condenser coils, and evaporators
• Inspection for refrigerant leaks and pressure performance (if applicable)
• Verification of proper airflow, fan operation, and defrost cycles

5. Temperature Calibration and Performance Testing

• Testing of temperature sensors and control boards
• Verification of temperature stability and uniformity throughout the chamber
• Testing of multiple setpoints (e.g., -20°C to -30°C) over extended operating periods

6. Safety and Compliance Checks

• Inspection of grounding and electrical insulation per lab safety standards
• Testing of alarm systems (if applicable) for temperature excursions or power failure

7. Final Quality Control and Documentation

• Multi-day operational test
• Final cleaning, inspection, and performance validation
• Detailed service report with temperature logs and repair notes

Trust the Experts at American Instrument Exchange

With over 50 years of industry experience, American Instrument Exchange is a leading provider of high-quality refurbished laboratory equipment. Our proven laboratory refrigerator refurbishment protocol ensures consistent, accurate cold storage—so you can safeguard your samples with confidence.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.