AirClean AC6036S Ductless Fume Hood
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The AirClean Systems AC6036S 6-foot ductless chemical fume hood provides a flexible laboratory ventilation solution for facilities that need chemical vapor containment without the expense and complexity of installing external exhaust ductwork. Available used and refurbished from American Instrument Exchange, this polypropylene fume hood combines a spacious working area, chemical-resistant construction, and advanced airflow monitoring with a recirculating filtration system designed for appropriately evaluated chemical applications.
Unlike conventional ducted chemical fume hoods that exhaust conditioned laboratory air outdoors, the AirClean AC6036S draws contaminated air through a specialized filtration system before returning filtered air to the laboratory. This configuration can significantly simplify installation in existing research facilities, pharmaceutical laboratories, quality control departments, and other environments where installing new ductwork may be impractical or costly.
With exterior dimensions of 72" W × 36" D × 60" H and an interior working area measuring approximately 66" W × 31" D × 36" H, this six-foot ductless fume hood provides generous space for laboratory apparatus, chemical handling, sample preparation, and other procedures requiring localized vapor containment.
Used and refurbished AirClean Systems AC6036S ductless chemical fume hood
Six-foot-wide enclosure with spacious 36-inch-deep exterior footprint
Chemical-resistant polypropylene construction
Tri-fold Plexiglas sash for convenient work area access
AirSafe automatic safety controller
AirZone baffling for controlled airflow through the enclosure
Built-in blower with adjustable airflow control
Electronic gas detection for filtration monitoring
Audible and visual low-airflow alarms
Filter safety lockout system
Configurable bonded carbon and particulate filtration
Deep integral spill-containment lip
Vapor-proof fluorescent work area lighting
No external exhaust ductwork required for approved applications
Filters not included; appropriate filters must be purchased separately
90-day warranty included from American Instrument Exchange
One of the primary advantages of the AirClean AC6036S is its ability to provide chemical vapor containment without requiring a conventional building exhaust system.
Traditional laboratory fume hoods generally require an external blower, dedicated ductwork, and sufficient building makeup air to replace the conditioned air exhausted outdoors. These installation requirements can add substantial cost to laboratory renovations and expansion projects.
The AC6036S uses a recirculating filtration design instead. Contaminated air is drawn into the enclosure, directed through the installed filtration media, and returned to the laboratory after treatment.
For facilities handling known chemicals in suitable quantities, this approach can provide greater flexibility in laboratory planning while reducing the need for extensive mechanical modifications.
However, ductless operation is not appropriate for every chemical or procedure. The chemicals being handled, anticipated vapor concentrations, filtration capacity, and operating conditions must be evaluated before the hood is placed into service.
The AirClean AC6036S is constructed from thermally fused polypropylene, providing excellent resistance to many corrosive chemicals and laboratory reagents.
Unlike painted steel enclosures, polypropylene does not rust, making it particularly attractive for laboratories where corrosive vapors, acidic solutions, or frequent chemical cleaning may accelerate deterioration of conventional metal surfaces.
The integral work area includes a deep spill-containment lip designed to help retain accidental liquid spills within the enclosure.
This construction is advantageous for chemical preparation, reagent handling, and analytical procedures where chemical resistance and ease of cleaning are important considerations.
The AC6036S incorporates AirClean Systems' AirSafe automatic safety controller, which monitors airflow conditions and helps maintain the operator-selected face velocity.
As operating conditions change, the controller adjusts airflow to support consistent containment performance. Audible and visual alarms alert operators when airflow falls below acceptable operating conditions.
The system also incorporates electronic gas detection for monitoring gas-phase filtration performance, providing an additional means of identifying conditions that may require attention.
These features help laboratories maintain awareness of enclosure operating conditions during chemical handling procedures.
AirClean's AirZone baffling system is designed to direct contaminated air through the enclosure in a controlled horizontal airflow pattern.
The baffling helps reduce stagnant areas where chemical vapors might otherwise accumulate and directs contaminated air toward the filtration system.
A brushless, sparkless blower positioned downstream of the filter assembly draws air through the enclosure. The filtration and electronic components are located above the working area, helping protect these systems from accidental chemical spills.
Together, these features provide a controlled ventilation environment for approved laboratory procedures.
The AC6036S accommodates different filtration configurations based on the chemicals and materials being handled.
AirClean Systems offers bonded activated carbon filtration for compatible chemical vapors and optional particulate filtration for applications involving airborne particles. Certain configurations can accommodate stacked filtration media to address both chemical vapor and particulate hazards.
The appropriate filter combination must be selected according to the laboratory's specific chemical inventory, quantities, expected evaporation rates, and operating procedures.
Filters are not included with this refurbished unit and must be selected and purchased separately before the hood is used for chemical containment.
The AirClean AC6036S can support a variety of laboratory procedures involving compatible chemical vapors and fumes when equipped with the correct filtration media.
Potential applications include analytical sample preparation, reagent formulation, small-scale solvent handling, pharmaceutical quality control, environmental testing, chemical transfers, laboratory instrument cleaning, and other procedures involving known chemicals.
Its large interior also provides room for reaction vessels, laboratory glassware, small analytical instruments, stirring equipment, and sample preparation apparatus.
Applications involving highly toxic substances, unknown chemical mixtures, substantial evaporation rates, or materials unsuitable for recirculating filtration may require a conventional ducted chemical fume hood instead.
The AC6036S is particularly well suited for pharmaceutical research laboratories, biotechnology facilities, analytical chemistry laboratories, industrial quality control departments, environmental testing laboratories, university research facilities, and other environments requiring flexible chemical containment.
It may be especially attractive for leased laboratories, renovated facilities, and existing laboratory spaces where installing dedicated exhaust ductwork would be difficult or expensive.
The six-foot working width makes it a practical choice for laboratories that need more interior space than smaller benchtop ductless enclosures provide.
| Specification | Details |
|---|---|
| Manufacturer | AirClean Systems |
| Model | AC6036S |
| AIE Product Code | 2834AA HOOD |
| Product Type | Ductless Chemical Fume Hood |
| Nominal Width | 6 feet |
| Exterior Dimensions | 72" W × 36" D × 60" H |
| Interior Dimensions | Approx. 66" W × 31" D × 36" H |
| Construction | Chemical-resistant polypropylene |
| Sash | Tri-fold Plexiglas |
| Airflow Controller | AirSafe automatic safety controller |
| Baffling | AirZone airflow management |
| Blower | Integrated, post-filter |
| Filtration | Configurable carbon and particulate filtration |
| Filters Included | No |
| Filter Monitoring | Electronic gas detection |
| Airflow Alarms | Audible and visual |
| Lighting | Vapor-proof fluorescent |
| Spill Containment | Integral base with deep spill lip |
| External Exhaust | Not required for approved applications |
| Electrical | Verify installed voltage configuration |
| Condition | Used and refurbished |
| Warranty | 90 days |
Specifications reflect the American Instrument Exchange listing and AirClean Systems product-family information. Confirm the installed electrical configuration and required filtration before purchase.
The ductless design of the AirClean AC6036S can simplify laboratory installation because it does not require connection to an external exhaust blower or building ductwork for approved applications.
Before installation, laboratories should verify available bench or stand space, electrical service, ceiling clearance, chemical compatibility, and the availability of suitable replacement filtration media.
Because the enclosure recirculates filtered air into the laboratory, an appropriate chemical risk assessment and filter-selection process are essential. The hood should not be operated for hazardous chemical procedures without suitable installed filters and verified airflow performance.
Laboratories should also consider ongoing filter replacement costs when comparing ductless and conventional ducted fume hood installations.
Ductless and ducted chemical fume hoods offer different advantages depending on laboratory requirements.
A ductless chemical fume hood such as the AirClean AC6036S can reduce installation complexity by eliminating the need for external exhaust ductwork. This can be especially advantageous for laboratories performing controlled procedures with known chemicals that are compatible with available filtration media.
A conventional ducted chemical fume hood exhausts contaminated air outside the building and may be more appropriate for laboratories handling a broader range of chemicals, unknown mixtures, high vapor loads, or substances that cannot be safely managed through recirculating filtration.
Choosing between these configurations should involve an evaluation of chemical hazards, ventilation requirements, operating costs, and the intended laboratory workflow.
This AirClean Systems AC6036S is inspected and refurbished by American Instrument Exchange before shipment. Our technicians evaluate the enclosure, blower, sash, lighting, airflow controls, monitoring systems, and other operating components as applicable to the individual unit.
The hood is cleaned and prepared for shipment after inspection and testing.
Because filters are not included, the laboratory must obtain suitable filtration media before placing the enclosure into service. Final airflow and filtration performance should be verified after installation according to the intended application and applicable laboratory safety procedures.
Purchasing a refurbished ductless chemical fume hood can provide laboratories with a cost-effective alternative to purchasing new containment equipment while potentially reducing the expense associated with installing conventional laboratory exhaust systems.
American Instrument Exchange supplies used and refurbished chemical fume hoods, biosafety cabinets, clean benches, and other laboratory equipment for research, pharmaceutical, educational, and industrial applications.
Our team can help customers compare available containment configurations and identify equipment appropriate for their laboratory space and intended workflow.
This AirClean Systems AC6036S includes a 90-day warranty from American Instrument Exchange.
No. The AC6036S is designed to operate as a ductless chemical fume hood for approved applications. Its built-in blower draws air through the installed filtration system before returning filtered air to the laboratory.
No. Filters are not included with this particular American Instrument Exchange unit. The appropriate filtration media must be selected and purchased separately according to the chemicals and procedures involved.
The polypropylene enclosure provides resistance to many corrosive chemicals, but enclosure construction and filtration suitability are separate considerations. The specific chemicals and expected vapor concentrations must be evaluated to determine whether the installed filtration system is appropriate.
The AirSafe controller monitors airflow conditions and adjusts blower performance to help maintain the selected face velocity. The system also provides alarms when airflow conditions require operator attention.
The interior measures approximately 66 inches wide, 31 inches deep, and 36 inches high, providing substantial room for laboratory glassware, instruments, and chemical handling equipment.
The hood can accommodate different filtration configurations, including bonded activated carbon and appropriate particulate filters. The correct combination depends on the chemicals and materials being handled, and not all hazards are suitable for ductless filtration.
Neither configuration is universally better. Ductless hoods can reduce installation costs and offer greater placement flexibility for compatible chemical applications. Ducted hoods are often more appropriate for broader chemical use, high vapor loads, and procedures unsuitable for recirculating filtration.
Yes. This refurbished AirClean Systems AC6036S includes a 90-day warranty from American Instrument Exchange.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.