AirClean Systems AC23824TE Vented Rotary Evaporator Enclosure
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The AirClean Systems AC23824TE is a specialized vented laboratory enclosure designed to provide operator protection from chemical fumes and solvent vapors generated during rotary evaporation. Available used and refurbished from American Instrument Exchange, this extra-tall equipment enclosure provides a dedicated containment workspace for rotary evaporators and associated laboratory apparatus, offering an alternative to placing evaporation equipment inside a conventional chemical fume hood.
Unlike a ductless filtration enclosure, the AirClean AC23824TE is designed for connection to an external laboratory exhaust system. Its total-exhaust configuration directs captured chemical vapors toward facility ventilation rather than returning filtered air to the laboratory.
The enclosure features horizontal sliding access doors, transparent panels for visibility, and an integral base with a raised spill-containment lip. American Instrument Exchange lists this unit at approximately 48" W × 24" D × 50" H, providing additional vertical clearance for rotary evaporator glassware, condensers, and related equipment.
Used and refurbished AirClean Systems AC23824TE enclosure
Specialized containment enclosure for rotary evaporators
Total-exhaust design for connection to laboratory ventilation
Extra-tall interior for rotary evaporator assemblies
Horizontal sliding access doors
Transparent enclosure panels for equipment visibility
Integral base with raised spill-containment lip
Dedicated access ports for electrical cables and equipment connections
Designed to capture chemical fumes and solvent vapors
Space-efficient alternative to a conventional chemical fume hood
External exhaust blower required
No integrated ductless carbon filtration
90-day warranty included from American Instrument Exchange
Rotary evaporators are commonly used to remove solvents from liquid samples through controlled heating, rotation, and reduced pressure. Although these instruments incorporate condensers and collection flasks to recover evaporated solvents, chemical vapors may still escape during setup, solvent collection, flask changes, or equipment servicing.
The AirClean AC23824TE provides a dedicated enclosure around the rotary evaporation system to help capture these vapors before they enter the surrounding laboratory.
Its taller design accommodates the vertical arrangement of a typical rotary evaporator, including the motor assembly, rotating evaporation flask, condenser, receiving flask, and associated glassware.
By enclosing the instrument while maintaining convenient operator access, the AC23824TE can provide a practical containment solution for laboratories performing routine solvent evaporation.
The AC23824TE is designed as a total-exhaust enclosure rather than a recirculating ductless fume hood.
When connected to a properly designed laboratory exhaust system, air is drawn inward through the enclosure openings and directed toward the exhaust connection. Chemical vapors generated inside the enclosure can then be carried away through the building ventilation system.
This arrangement differs from a ductless fume hood that uses activated carbon or other filtration media before returning air to the laboratory.
A properly configured total-exhaust system may be advantageous for rotary evaporation applications involving solvents that are unsuitable for recirculating filtration.
The enclosure itself does not include an integrated blower. A compatible exhaust source, appropriate ductwork, and airflow verification are required before it can be relied upon for chemical vapor containment.
Conventional benchtop chemical fume hoods may not provide enough vertical clearance for certain rotary evaporators, particularly models equipped with tall condensers or larger receiving flasks.
The AirClean AC23824TE addresses this challenge with an enclosure specifically intended to accommodate rotary evaporation equipment.
The additional height allows operators to position the rotary evaporator inside the enclosure while retaining access to the condenser, evaporation flask, collection vessel, and instrument controls.
This equipment-focused design makes the AC23824TE especially useful for laboratories that need dedicated solvent evaporation containment without occupying an entire conventional chemical fume hood.
Before purchase, laboratories should compare the dimensions of their rotary evaporator and accessories with the actual enclosure opening and interior dimensions.
The AC23824TE incorporates horizontal sliding doors that provide convenient access to the enclosed rotary evaporator.
Unlike a conventional vertically rising fume hood sash, horizontal doors allow operators to open the portion of the enclosure needed for a particular task while retaining much of the surrounding enclosure structure.
This arrangement is useful for changing evaporation flasks, adjusting instrument settings, checking condenser connections, and removing collected solvent.
Transparent panels provide visibility into the enclosure so operators can monitor the evaporation process without unnecessarily opening the doors.
The access configuration should be used in accordance with the airflow requirements of the installed exhaust system.
Rotary evaporation procedures involve solvent-filled glassware, receiving vessels, tubing, and other components that may occasionally leak or spill during handling.
The AirClean AC23824TE includes an integral base with a raised lip designed to help contain incidental liquid spills within the enclosure.
This feature provides an additional measure of workspace organization and spill management, although it does not replace appropriate chemical handling procedures or secondary containment where required.
The enclosure also incorporates access ports that allow electrical cables and equipment connections to pass through the enclosure wall.
These ports can help laboratories accommodate rotary evaporator power connections and related equipment without routing every cable through the sliding door opening.
The AirClean AC23824TE is designed primarily for rotary evaporation and associated solvent-handling procedures. Typical applications include solvent removal from laboratory samples, sample concentration, organic chemistry preparation, extraction solvent recovery, pharmaceutical research, analytical sample preparation, and purification workflows.
The enclosure may also be suitable for other laboratory equipment requiring additional vertical clearance and localized exhaust, provided the equipment fits and the complete ventilation system is appropriate for the hazards involved.
The enclosure's suitability should be determined by the chemicals, quantities, equipment configuration, and laboratory ventilation requirements.
The AC23824TE is particularly well suited for pharmaceutical research and development laboratories, analytical chemistry facilities, organic synthesis laboratories, biotechnology research departments, environmental testing laboratories, university chemistry laboratories, and industrial quality control facilities.
It may be especially useful where rotary evaporation is performed regularly and a dedicated containment workstation would improve laboratory organization or preserve conventional chemical fume hood space for other procedures.
| Specification | Details |
|---|---|
| Manufacturer | AirClean Systems |
| Model | AC23824TE |
| AIE Product Code | 2834I HOOD |
| Product Type | Vented Rotary Evaporator Enclosure |
| Enclosure Series | AirClean 200 Series |
| Primary Application | Rotary evaporator containment |
| Ventilation Type | Total exhaust |
| Exterior Dimensions Listed by AIE | 48" W × 24" D × 50" H |
| Interior Dimensions | Verify for individual unit |
| Door Configuration | Horizontal sliding doors |
| Enclosure Panels | Transparent panels |
| Base | Integral with raised spill-containment lip |
| Equipment Access | Two cable/access ports per published model description |
| Exhaust Connection | Duct connection; published model description references a 5" coupling |
| Built-In Blower | No |
| External Blower | Required |
| Built-In Carbon Filtration | No |
| Electrical Requirements | Determined by connected equipment and accessories |
| Condition | Used and reconditioned |
| Warranty | 90 days |
The exterior dimensions are taken from the AIE listing. Published third-party specifications for AC23824TE conflict with those dimensions, so the actual unit should be measured before finalizing installation plans.
Proper exhaust installation is essential to the performance of the AirClean AC23824TE.
The enclosure must be connected to a suitable laboratory exhaust system capable of maintaining the required inward airflow during normal rotary evaporator operation.
The ventilation design should account for duct diameter, duct length, elbows, static pressure, the chemicals being handled, and the airflow required to contain vapors at the enclosure opening.
Because a blower is not included, laboratories should confirm that an appropriate exhaust source is available before purchasing the unit.
Following installation, the complete system should be evaluated to verify airflow and containment performance under representative operating conditions.
A specialized rotary evaporator enclosure and a conventional chemical fume hood can both provide chemical vapor containment when properly designed and installed, but they serve somewhat different laboratory needs.
A conventional chemical fume hood provides a general-purpose workspace for a wide range of chemical handling procedures. It may accommodate rotary evaporators, depending on the available height, sash configuration, and instrument dimensions.
The AirClean AC23824TE is designed specifically for equipment containment. Its extra-tall interior and horizontal sliding doors accommodate rotary evaporator assemblies while providing access to the equipment.
For laboratories performing frequent rotary evaporation, a dedicated enclosure may help preserve valuable fume hood space and provide a more convenient workstation for solvent concentration procedures.
This AirClean Systems AC23824TE is inspected and reconditioned by American Instrument Exchange before shipment.
Our technicians inspect the enclosure's structural condition, sliding doors, access openings, exhaust components, and other applicable features. The unit is cleaned and prepared for shipment as part of the refurbishment process.
Because the enclosure requires an external exhaust source, final airflow and containment performance must be verified after installation with the laboratory's intended ventilation system.
Purchasing a refurbished rotary evaporator enclosure can provide laboratories with an economical way to add dedicated solvent evaporation containment without purchasing an entirely new ventilation enclosure.
American Instrument Exchange supplies a broad selection of used and refurbished chemical fume hoods, laboratory ventilation enclosures, and rotary evaporators and related equipment.
AIE also offers vacuum pumps, recirculating chillers and circulators, and other equipment commonly used in laboratory evaporation workflows.
This AirClean Systems AC23824TE includes a 90-day warranty from American Instrument Exchange.
The AC23824TE is a specialized vented enclosure designed primarily to contain chemical fumes and solvent vapors generated during rotary evaporator operation. Its extra-tall design accommodates rotary evaporator glassware and related equipment.
No. The AC23824TE is a total-exhaust enclosure designed for connection to a laboratory exhaust system. It is not a recirculating ductless hood with built-in carbon filtration.
No. The published model information identifies the AC23824TE as an enclosure without an integrated blower. A properly sized external exhaust system is required.
The enclosure is designed with additional vertical clearance for rotary evaporator assemblies. However, laboratories should verify the actual interior dimensions and door opening against their specific instrument before purchase.
Horizontal sliding doors allow operators to access portions of the enclosure for changing flasks, adjusting controls, and servicing equipment while retaining visibility of the rotary evaporator.
Yes. The enclosure incorporates an integral base with a raised spill-containment lip intended to help contain incidental liquid spills.
Potentially, provided the enclosure materials and complete exhaust system are appropriate for the chemicals being handled. Solvent compatibility, vapor hazards, and ventilation performance should be evaluated before use.
Yes. Because the AC23824TE depends on an external exhaust system, airflow and containment performance should be verified after installation before the enclosure is used for hazardous solvent procedures.
Yes. This used and refurbished AirClean AC23824TE includes a 90-day warranty from American Instrument Exchange.
Click Here to see the Air Clean enclosure on the American Instrument Exchange YouTube channel.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.