Thermo Scientific 1361 6' Class II Type B2 Biosafety Cabinet

Fully Tested & Warrantied*
Brand : Thermo
Product Code : SKU 0870C BIO CAB
Size: 8900.00
Color: 03-29-2024

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Thermo Scientific 1361 6' Class II Type B2 Biosafety Cabinet

Refurbished Thermo Scientific 1361 Type B2 Biosafety Cabinet for Sale

The Thermo Scientific 1361 is a 6-foot Class II Type B2 biosafety cabinet designed for specialized laboratory applications requiring total-exhaust biological containment. Unlike a conventional Type A2 biosafety cabinet that recirculates a portion of HEPA-filtered air within the cabinet, the Thermo 1361 is designed so that 100% of cabinet air is exhausted through a dedicated external exhaust system. This configuration makes the 1361 particularly useful for specialized microbiological, pharmaceutical, toxicology, hazardous-drug, and research applications where limited quantities of volatile toxic chemicals or trace radionuclides may be used in conjunction with biological materials.

The 6-foot work area is an important advantage of the Thermo 1361. With approximately 71.25 inches of usable interior width, the cabinet provides considerably more working room than a 4-foot B2 cabinet. This additional space can accommodate larger experimental setups, multiple culture vessels, sample racks, media containers, aspiration equipment, and other materials while giving researchers more room to organize workflows without unnecessarily crowding the work chamber.

The 1361 combines this large workspace with an 8-inch working sash opening, one-piece 304 stainless steel interior, stainless steel work surface, DC motor technology, and HEPA-filtered supply and exhaust airflow. The stainless steel chamber provides a durable surface well suited to frequent cleaning and disinfection in demanding research and pharmaceutical environments.

Because the Thermo 1361 is a Type B2 total-exhaust cabinet, installation requirements are substantially different from those of a typical Type A2 BSC. The cabinet must be connected to a properly designed external exhaust system, and the laboratory must have sufficient exhaust and makeup-air capacity to support continuous operation. Facility HVAC requirements, ductwork, room balance, exhaust discharge, and certification should therefore be evaluated before purchasing or installing this cabinet.

At American Instrument Exchange, each Thermo Scientific 1361 biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Because a Type B2 cabinet depends on the facility exhaust system to establish its final operating conditions, complete airflow performance must ultimately be verified after installation, connection to the external exhaust system, balancing, and field certification. This refurbished unit is backed by a 90-day warranty from American Instrument Exchange.

Key Features

  • Class II Type B2 biosafety cabinet

  • 100% total-exhaust configuration

  • Requires connection to a dedicated external exhaust system

  • Large 6-foot cabinet configuration

  • Approximately 71.25-inch-wide interior workspace

  • 8-inch working sash opening

  • One-piece 304 stainless steel interior

  • 304 stainless steel work surface

  • HEPA-filtered supply and exhaust airflow

  • DC motor technology

  • Designed for specialized biological and chemical-containing workflows

  • Appropriate for certain applications involving limited quantities of volatile toxic chemicals or trace radionuclides

  • Two duplex electrical outlets

  • UV light

  • 115/120V, 60 Hz electrical configuration

  • Stand included

  • New HEPA filters included unless otherwise specified

  • 90-day warranty from American Instrument Exchange

Overview

The Thermo Scientific 1361 combines the large working area of a 6-foot biosafety cabinet with the specialized airflow characteristics of a Class II Type B2 total-exhaust system.

As a Class II cabinet, the 1361 is designed to provide personnel, product, and environmental protection for appropriate biological procedures. Room air enters through the front opening to help protect the operator, while HEPA-filtered vertical downflow helps maintain a clean work environment for samples and materials inside the cabinet.

The critical distinction is what happens to the air after it moves through the work chamber. In a Type B2 cabinet, contaminated air is collected through the cabinet's grilles, passes through HEPA filtration, and is then removed from the laboratory through the dedicated external exhaust system. Cabinet air is not recirculated back through the work zone.

This total-exhaust arrangement makes the 1361 a specialized choice for laboratories whose procedures require the characteristics of a Type B2 BSC. It can be particularly relevant when biological containment must be combined with appropriate use of limited quantities of volatile toxic chemicals or trace radionuclides.

The 6-foot workspace further distinguishes the 1361. Its approximately 71.25-inch interior width provides significantly more working room than a typical 4-foot cabinet, making it useful for procedures involving larger experimental setups, higher sample volumes, multiple culture vessels, or more extensive equipment inside the work area.

That additional workspace comes with a corresponding facility requirement: a 6-foot Type B2 cabinet represents a substantial exhaust load. Laboratories should therefore evaluate both the physical footprint and the mechanical requirements before selecting the 1361.

Why Choose a 6-Foot Thermo Scientific 1361 Type B2?

The Thermo Scientific 1361 is particularly well suited for laboratories that need both Type B2 total-exhaust containment and a large working area.

A 4-foot B2 cabinet can be sufficient for many procedures, but its workspace may become restrictive when researchers need to accommodate multiple culture vessels, larger experimental setups, extensive sample racks, aspiration equipment, or other supporting materials.

The 1361 provides approximately 71.25 inches of interior working width, allowing researchers to organize more complex workflows while maintaining appropriate separation between clean and potentially contaminated materials.

For pharmaceutical research, hazardous-drug applications, toxicology, microbiology, and other specialized workflows, that additional room can be valuable when procedures cannot be comfortably performed within a smaller cabinet.

The larger cabinet should not automatically be considered the better choice, however. A 6-foot Type B2 BSC generally requires greater facility exhaust capacity than a smaller B2 cabinet and occupies substantially more laboratory space. The 1361 is therefore most appropriate when the laboratory genuinely needs its combination of large workspace and total-exhaust operation.

Type B2 vs. Type A2 Biosafety Cabinets

Understanding the difference between Type B2 and Type A2 biosafety cabinets is essential before selecting the Thermo Scientific 1361.

A Class II Type A2 biosafety cabinet recirculates a substantial portion of HEPA-filtered air within the cabinet while exhausting the remainder through HEPA filtration. For routine cell culture, microbiology, biotechnology, and many other biological research applications, Type A2 cabinets provide an efficient and practical containment solution.

The Thermo 1361 Type B2, by comparison, is designed for total exhaust. Air moving through the cabinet is ultimately discharged from the building through a dedicated exhaust system rather than recirculated through the work chamber.

This configuration can be appropriate for certain procedures involving biological materials together with limited quantities of volatile toxic chemicals or trace radionuclides, provided the work is compatible with Type B2 operation and approved through the laboratory's risk assessment and safety procedures.

It is important to remember that HEPA filters capture particulates; they do not remove chemical vapors or gases. The external exhaust system is therefore fundamental to the B2 configuration when appropriate volatile chemicals are involved.

A Type B2 cabinet should not be selected simply because it sounds more protective than an A2. The correct cabinet type depends on the hazards, procedures, facility infrastructure, and applicable safety requirements.

HVAC & External Exhaust Requirements

Facility exhaust capacity is one of the most important considerations when purchasing a Thermo Scientific 1361.

The 1361 must be connected to a properly designed external exhaust system. Thermo's installation documentation specifically calls for consideration of the cabinet's exhaust duct before the installation location is selected and identifies a 10-inch duct path above the cabinet.

The area above the exhaust connection should therefore be evaluated for structural members, utility lines, piping, and other obstructions before the cabinet is installed. Excessive bends or an elbow immediately above the exhaust connection can complicate proper installation.

The building must also provide adequate makeup air to replace the large volume of room air removed during cabinet operation. Insufficient replacement air can affect room pressure relationships and interfere with the operation of the BSC or other laboratory ventilation systems.

Before purchasing a refurbished Thermo 1361, laboratories should have the proposed installation reviewed by qualified facility, HVAC, biosafety, and certification personnel. Important considerations include available exhaust capacity, duct configuration, static pressure, makeup air, room balance, exhaust discharge location, and applicable building and laboratory safety requirements.

This is particularly important when replacing a Type A2 cabinet. Even if the laboratory has sufficient physical space for the 1361, the existing HVAC system may not have the capacity required to operate a 6-foot Type B2 cabinet.

Testing a Refurbished Thermo 1361 Type B2 Biosafety Cabinet

Testing a refurbished Type B2 cabinet requires a different approach from testing a recirculating Type A2 biosafety cabinet because the final airflow performance of the B2 depends on the external exhaust system.

American Instrument Exchange technicians inspect and test the Thermo 1361's controls, electrical systems, alarms, lighting, sash operation, filtration components, and other accessible cabinet functions at our facility. Unless otherwise specified, new HEPA filters are installed before shipment.

The stainless steel interior and work surface are professionally cleaned and inspected, and worn or damaged functional components are repaired or replaced whenever practical as part of the refurbishment process.

However, American Instrument Exchange cannot reproduce every customer's hard-ducted building exhaust system at our warehouse. As a result, final Type B2 airflow conditions cannot be established solely through warehouse testing.

After delivery, the 1361 must be installed, connected to the facility exhaust system, properly balanced, and field certified before being placed into service.

This distinction is particularly important when purchasing a used or refurbished Type B2 cabinet. Successful installation depends on both the condition of the cabinet and its proper integration with the laboratory's mechanical systems.

Common Applications

The Thermo Scientific 1361 may be appropriate for specialized laboratory procedures requiring biological containment together with the total-exhaust characteristics of a Class II Type B2 cabinet.

Potential applications include pharmaceutical research and development, hazardous-drug research and preparation, toxicology, microbiology, virology, biotechnology research, specialized cell culture procedures, and research involving appropriate quantities of volatile toxic chemicals or trace radionuclides.

The suitability of a Type B2 cabinet should always be determined based on the actual materials, quantities, procedures, facility infrastructure, and laboratory risk assessment rather than cabinet classification alone.

Ideal Laboratory Environments

The Thermo Scientific 1361 is best suited for pharmaceutical companies, biotechnology facilities, hospital and clinical research laboratories, toxicology laboratories, universities, government research facilities, and other organizations that specifically require Class II Type B2 containment and have the infrastructure necessary to support a large total-exhaust cabinet.

Its 6-foot configuration makes it especially attractive for higher-throughput or equipment-intensive workflows where a 4-foot B2 cabinet does not provide sufficient working room.

For laboratories performing routine cell culture or microbiology without a requirement for total exhaust, a Type A2 cabinet may provide a simpler and substantially less demanding installation.

Key Specifications

Specification Details
Manufacturer Thermo Scientific
Model 1361
Series 1300 Series B2
Cabinet Type Class II Type B2 Biosafety Cabinet
Exhaust Configuration 100% Total Exhaust
External Exhaust Required
Nominal Cabinet Width 6 ft
Exterior Dimensions Approximately 78" W × 32" D × 62" H
Workspace Dimensions Approximately 71.25" W × 18.5" D × 27.75" H
Working Sash Opening 8"
Interior Side & Rear Walls One-Piece 304 Stainless Steel
Work Surface 304 Stainless Steel
Exterior Construction Powder-Coated Steel
Filtration HEPA Supply and Exhaust
Motor Type DC
Operating Power Consumption Approximately 370 W
Electrical 115/120V, 60 Hz, 12A
Electrical Outlets 2 Duplex, US
UV Light Included
Exhaust Ducting External Exhaust Required
Stand Included
HEPA Filters New Filters Included Unless Otherwise Specified
Warranty 90 Days from American Instrument Exchange

Specifications compiled from Thermo Scientific manufacturer literature and American Instrument Exchange product information.

Why Buy a Refurbished Thermo Scientific 1361 Type B2 Biosafety Cabinet?

The Thermo Scientific 1361 offers a specialized combination of Class II Type B2 total-exhaust containment and a large 6-foot working area. For pharmaceutical, biotechnology, toxicology, microbiology, and other research facilities that specifically require B2 operation, a professionally refurbished 1361 can provide a cost-effective alternative to purchasing a new total-exhaust biosafety cabinet.

The 6-foot configuration is particularly valuable for procedures requiring more working room than a conventional 4-foot B2 can provide. With approximately 72 inches of interior width, researchers have substantial space for culture vessels, sample racks, media containers, aspiration equipment, and other materials used during complex or higher-throughput procedures.

For laboratories replacing an existing 6-foot Type B2 cabinet, a refurbished Thermo 1361 may be especially attractive. B2 installations require dedicated external exhaust infrastructure, and changing to a substantially different cabinet can involve modifications to ductwork, HVAC systems, room balance, and surrounding laboratory equipment. When an appropriate replacement can utilize an existing installation, maintaining a similar cabinet configuration may simplify the project.

The Thermo 1361 also features a one-piece 304 stainless steel interior, stainless steel work surface, 8-inch operating opening, DC motor technology, and factory-installed UV light. Combined with its total-exhaust airflow configuration, these characteristics make it a highly specialized cabinet for laboratories whose applications and facilities genuinely require Type B2 containment.

Refurbishment & Testing Process

Every Thermo Scientific 1361 offered by American Instrument Exchange undergoes a detailed inspection, cleaning, refurbishment, and functional testing process prior to shipment. Our technicians evaluate the cabinet's mechanical, electrical, control, blower, alarm, sash, and filtration systems and identify components requiring repair or replacement.

Unless otherwise specified, new HEPA filters are installed at our facility before shipment. The stainless steel interior and work surface are professionally cleaned and inspected, while controls, lighting, electrical components, alarms, sash operation, and other accessible cabinet functions are tested for proper operation.

There is an important distinction, however, between testing a refurbished Type B2 cabinet at our facility and verifying its final containment performance after installation.

The Thermo 1361 depends on a properly designed external exhaust system to establish its final operating conditions. American Instrument Exchange cannot reproduce every customer's hard-ducted building exhaust system at our warehouse. As a result, the cabinet's final airflow performance must be verified after installation, connection to the facility exhaust system, balancing, and field certification.

This distinction is particularly important when purchasing a used or refurbished Type B2 biosafety cabinet. Successful operation depends on both the condition of the cabinet and its proper integration with the laboratory's mechanical systems.

Certification Readiness

The Thermo Scientific 1361 is a Class II Type B2 biosafety cabinet designed for total-exhaust containment applications. The Thermo 1300 Series B2 platform was tested and certified in accordance with NSF/ANSI 49 requirements.

Proper field certification is essential after installation because the cabinet's performance depends on both the BSC itself and the external exhaust system to which it is connected.

Certification may include inflow and downflow velocity measurements, HEPA filter integrity testing, airflow visualization, alarm verification, sash operation, exhaust performance, and other applicable certification procedures.

Biosafety cabinets should also be recertified at appropriate intervals and following events that may affect containment performance, including relocation, HEPA filter replacement, modifications to the exhaust system, or significant internal service.

For laboratories throughout Greater Boston and New England, AIE Laboratory Services provides biosafety cabinet certification, preventative maintenance, troubleshooting, repairs, HEPA filter replacement, decontamination, and related field services.

Customers planning a Thermo 1361 installation should coordinate facility exhaust work and final cabinet certification so that the complete system can be evaluated under actual operating conditions.

Shipping & Installation

The Thermo Scientific 1361 is a large 6-foot biosafety cabinet and should be carefully planned for before delivery. Customers should verify doorway widths, hallways, elevators, loading areas, ceiling clearance, electrical service, and the dimensions of the final installation location.

For a Type B2 cabinet, however, physical fit is only part of the installation equation.

The Thermo 1361 requires direct connection to a dedicated external exhaust system. The building must provide sufficient exhaust capacity and replacement air to operate the cabinet without creating unacceptable room pressure conditions or interfering with other laboratory ventilation equipment.

The 1361 requires approximately 998 CFM of exhaust airflow, making HVAC capacity an especially important consideration. The exhaust system must also be capable of maintaining the required negative static pressure as resistance across the exhaust HEPA filter changes over its service life.

Facility engineers, HVAC professionals, biosafety personnel, and the certification company responsible for the installation should therefore be involved before the cabinet is placed into service.

American Instrument Exchange can assist with freight coordination, inside delivery, equipment placement, and installation planning when required. Once installed and connected to the building exhaust system, the cabinet must be properly balanced and field certified before use.

Related Laboratory Equipment

The Thermo Scientific 1361 may be incorporated into pharmaceutical, biotechnology, toxicology, microbiology, hazardous-drug research, and other specialized laboratory workflows requiring Type B2 containment.

Depending on the application, the cabinet may be paired with laboratory refrigerators and freezers for reagent and sample storage, refrigerated centrifuges for sample processing, CO₂ incubators for cell culture workflows, and ultra-low temperature freezers for long-term biological sample preservation.

American Instrument Exchange maintains a broad inventory of professionally refurbished laboratory equipment, allowing laboratories to source multiple pieces of compatible equipment through a single supplier while simplifying procurement and reducing equipment lead times.

Thermo Scientific 1361 Frequently Asked Questions

Is the Thermo Scientific 1361 a Class II Type B2 biosafety cabinet?

Yes. The Thermo Scientific 1361 is a 6-foot Class II Type B2 biosafety cabinet from Thermo's 1300 Series B2 platform.

It is designed as a total-exhaust cabinet and requires connection to an appropriate external exhaust system.

Is the Thermo 1361 a 6-foot biosafety cabinet?

Yes. The Thermo 1361 is a 6-foot nominal-width BSC. The cabinet measures approximately 78 inches wide externally and provides approximately 72 inches of interior working width.

The large work area can be advantageous for higher-throughput procedures, larger experimental setups, or applications requiring more equipment and materials inside the cabinet.

Does the Thermo 1361 need to be hard ducted?

Yes. The Thermo 1361 is a Type B2 cabinet and requires direct connection to an external exhaust system.

It cannot simply be installed and operated as a recirculating Type A2 cabinet. The facility exhaust system is an integral part of proper Type B2 operation.

How much exhaust airflow does the Thermo 1361 require?

Thermo specifies an exhaust requirement of approximately 998 CFM for the 6-foot 1300 Series B2 cabinet.

The external exhaust system must be capable of drawing this volume against approximately 1.5 inches w.g. negative static pressure with a new exhaust HEPA filter and up to 2.0 inches w.g. as the filter loads prior to replacement.

Because this represents a substantial continuous exhaust demand, HVAC compatibility should be confirmed before purchasing or installing the cabinet.

What size exhaust connection does the Thermo 1361 use?

Thermo's 1300 Series B2 documentation specifies a 10-inch-diameter airtight damper for this platform.

Laboratories replacing an existing B2 cabinet should still verify the existing ductwork, connection dimensions, available static pressure, exhaust capacity, and installation conditions rather than assuming that two 6-foot B2 cabinets will be direct mechanical replacements.

Can I replace an existing 6-foot B2 with a Thermo 1361 without changing the ductwork?

Possibly, but this should be verified before purchase.

Even when two cabinets have similar exterior dimensions, their required exhaust volume, static pressure, exhaust connection, cabinet height, and duct location may differ.

If the Thermo 1361 is replacing an existing Type B2 cabinet, providing American Instrument Exchange with the manufacturer, model, exhaust specifications, and photographs or dimensions of the existing installation can help identify potential compatibility issues.

A qualified HVAC professional and BSC certifier should ultimately verify the installation requirements.

Why choose a 6-foot B2 instead of a 4-foot B2?

The primary advantage is working space.

A 6-foot cabinet such as the Thermo 1361 provides approximately 72 inches of interior width, making it useful for larger experimental setups, multiple culture vessels, extensive sample racks, or procedures requiring more equipment inside the work chamber.

The tradeoff is significantly greater physical size and facility exhaust demand. A 6-foot B2 should therefore be selected when the additional workspace provides a genuine workflow advantage.

How does the Thermo 1361 compare with the Thermo 1510?

Both are Class II Type B2 total-exhaust biosafety cabinets, but they belong to different Thermo product families and provide substantially different working widths.

The Thermo 1361 is a 6-foot 1300 Series B2 cabinet, while the Thermo 1510 is a 4-foot 1500 Series B2 cabinet.

The 1361 provides substantially more workspace but also places a greater demand on the facility exhaust system. Laboratories choosing between them should consider required working area, available laboratory space, exhaust capacity, existing ductwork, and the intended application.

Can the Thermo 1361 be used with volatile toxic chemicals?

A Type B2 cabinet is designed for applications requiring greater dilution and removal of volatile toxic chemicals than a recirculating BSC configuration can provide.

However, HEPA filters capture particulates; they do not remove chemical vapors or gases. The dedicated external exhaust system is therefore critical when appropriate volatile chemicals are used.

Whether a particular chemical, concentration, quantity, or procedure is appropriate for use in the cabinet should be determined through the laboratory's formal risk assessment and applicable biosafety, chemical safety, and regulatory requirements.

Can the Thermo 1361 be used with radionuclides?

Type B2 cabinets may be appropriate for certain procedures involving trace quantities of radionuclides when biological containment is also required.

Suitability depends on the isotope, quantity, procedure, facility design, contamination-control requirements, and applicable radiation safety regulations. The laboratory's radiation safety officer and other appropriate safety personnel should approve the intended application before use.

Does the Thermo 1361 have a stainless steel interior?

Yes. The Thermo 1361 features one-piece 304 stainless steel interior side and rear walls and a 304 stainless steel work surface.

This provides a durable work chamber well suited to routine cleaning and decontamination procedures.

Does the Thermo 1361 have a UV light?

Yes. The 1361 is the factory UV-equipped version of this 6-foot, 115/120V Thermo 1300 Series B2 configuration.

The closely related Thermo 1360 uses the same basic 6-foot platform but is the corresponding configuration without factory-installed UV lighting.

UV should not be treated as a replacement for appropriate cleaning and decontamination procedures.

What happens if the building exhaust system fails?

Loss of external exhaust can compromise the operating conditions required for a Type B2 biosafety cabinet.

The Thermo 1300 Series B2 incorporates alarm contacts associated with conditions including airflow alerts, exhaust errors, airflow sensor errors, and filter-related warnings.

An exhaust or airflow failure should be treated as a condition requiring evaluation. The cabinet should not be assumed to provide proper containment when required external exhaust conditions are not being maintained.

Can American Instrument Exchange completely test the Thermo 1361 before shipment?

American Instrument Exchange can inspect and test the cabinet's mechanical, electrical, control, filtration, alarm, sash, and other accessible functional systems. Unless otherwise specified, new HEPA filters are installed before shipment.

However, final Type B2 airflow performance cannot be established independently of the customer's external exhaust system.

The cabinet must therefore be installed, connected to the building exhaust, properly balanced, and field certified before being placed into service.

What information should I provide before ordering a refurbished Thermo 1361?

Because the 1361 is a large Type B2 cabinet, customers should verify more than simply the available floor space.

Important information includes the available exhaust airflow, static pressure, duct diameter and location, makeup-air capacity, room pressure requirements, electrical service, delivery route, doorway and elevator dimensions, and final installation location.

If the cabinet is replacing an existing B2, information about the existing cabinet and exhaust connection can also be helpful when evaluating compatibility.

Does the Thermo 1361 need to be certified after installation?

Yes. The cabinet should be field certified after installation and before being placed into service.

This is especially important for a Type B2 cabinet because final containment performance depends on the relationship between the BSC and the facility exhaust system.

The cabinet should also be recertified following relocation, HEPA filter replacement, exhaust-system modifications, or other service that could affect containment performance.

Can AIE Laboratory Services certify or repair a Thermo 1361 Type B2?

For laboratories throughout Greater Boston and New England, AIE Laboratory Services can provide biosafety cabinet certification, preventative maintenance, troubleshooting, HEPA filter replacement, repairs, decontamination, and related services.

Type B2 work may also require coordination with the facility's HVAC personnel because proper cabinet operation depends on the external exhaust system.

I already own a Thermo 1361. Is it worth repairing?

In many cases, an evaluation is worthwhile before replacing the cabinet.

A Type B2 cabinet is integrated into the building's exhaust infrastructure, so replacement can involve considerably more than simply removing one BSC and installing another. Changes in cabinet dimensions, exhaust volume, static-pressure requirements, or duct location can potentially require mechanical modifications.

Problems involving controls, alarms, blowers, sensors, sash components, electrical systems, or HEPA filters do not necessarily mean the entire cabinet must be replaced.

For laboratories throughout New England, AIE Laboratory Services can evaluate an existing Thermo 1361 and help determine whether repair or replacement is the more practical approach.

I purchased my Thermo 1361 somewhere else. Can AIE Laboratory Services still service it?

Yes. The cabinet does not need to have been purchased from American Instrument Exchange for AIE Laboratory Services to evaluate, maintain, troubleshoot, repair, or certify it.

This can be particularly valuable for facilities operating older hard-ducted B2 cabinets where maintaining the existing installation may be preferable to replacing the entire system.

Are new HEPA filters installed in this refurbished Thermo 1361?

Unless otherwise specified, American Instrument Exchange installs new HEPA filters prior to shipment.

Because final B2 performance depends on the facility exhaust system, the cabinet must still be installed, balanced, and field certified at its final operating location before use.

Can American Instrument Exchange help replace an older 6-foot Type B2 cabinet?

Yes. American Instrument Exchange can help laboratories compare available refurbished Type B2 cabinets when an existing unit needs replacement.

For a hard-ducted B2 installation, matching the replacement cabinet as closely as possible can be particularly valuable. Cabinet width, height, exhaust connection, airflow requirement, static pressure, electrical service, and duct location should all be considered.

If an exact Thermo 1361 is unavailable, American Instrument Exchange may be able to identify another refurbished 6-foot Type B2 cabinet that meets the laboratory's application and facility requirements.

Why purchase a refurbished Thermo Scientific 1361 from American Instrument Exchange?

American Instrument Exchange specializes in professionally refurbished laboratory equipment rather than simply reselling used instruments. Each Thermo Scientific 1361 is inspected, cleaned, tested, and prepared for continued laboratory service by experienced technicians.

Unless otherwise specified, new HEPA filters are installed prior to shipment, and the unit is backed by a 90-day warranty from American Instrument Exchange.

For laboratories specifically requiring a 6-foot Class II Type B2 biosafety cabinet, the Thermo 1361 provides a compelling combination of approximately 72 inches of working width, stainless steel construction, total-exhaust containment, and the proven Thermo 1300 Series B2 platform.

Because replacing a hard-ducted Type B2 cabinet can involve significant HVAC and installation considerations, American Instrument Exchange can also help customers evaluate available equipment and plan for a practical replacement rather than treating the cabinet as a simple plug-and-play purchase.

CLICK HERE to see the Thermo 1361 6' biosafety cabinet on our YouTube channel

Testing Procedures for Used and Refurbished Biosafety Cabinets

Ensure Containment, Airflow Integrity, and Operator Safety

Used and refurbished biosafety cabinets (BSCs) from American Instrument Exchange are thoroughly tested to ensure they meet NSF/ANSI 49 performance standards for containment, airflow uniformity, and HEPA filtration. Each Class I, II, or III unit is evaluated through a series of specialized inspections and certifications, ensuring the cabinet performs reliably in research, clinical, and pharmaceutical lab environments.

Why Testing Used Biosafety Cabinets Is Essential

Before any biosafety cabinet is deployed in a working lab, it must be tested for:

• HEPA filter integrity and leak-free performance
• Inflow and downflow air velocity balance
• Containment efficiency and personnel protection
• Electrical system function and safety compliance
• Cleanliness and readiness for sterile applications

Proper testing of refurbished biosafety cabinets helps prevent cross-contamination, exposure to hazardous materials, and airflow disruption—critical for maintaining laboratory protocols. Our structured multi-point BSC testing protocol ensures dependable protection for operators, products, and the lab environment.

Key Testing Procedures for Refurbished and Used Biosafety Cabinets

1. Initial Visual Inspection

• Inspect exterior panels, window sashes, hinges, and seals for signs of wear or damage
• Confirm visibility and integrity of the viewing window
• Check power cords, display screens, and control interfaces for usability

2. Cabinet Decontamination and Cleaning

• Interior and exterior cleaned with non-corrosive disinfectants
• Decontamination protocols followed to remove biological contaminants
• Work surface, sidewalls, and return air grills are fully sanitized

3. HEPA Filter Integrity Testing (DOP/PAO Leak Test)

• Conduct aerosol challenge test using PAO or DOP to verify HEPA filter seal integrity
• Identify and resolve any filter leaks in accordance with NSF/ANSI 49 standards
• Ensure HEPA filters are correctly seated and uncompromised

4. Inflow and Downflow Velocity Testing

• Measure air velocities using calibrated thermo-anemometers
• Confirm inflow velocity meets requirements
• Verify downflow uniformity within the work zone to prevent turbulence and contamination

5. Airflow Smoke Pattern Testing

• Conduct visual smoke tests to demonstrate laminar airflow and containment
• Confirm that airflow barriers prevent cross-contamination and exposure

6. Electrical Safety and Alarm System Checks

• Inspect grounding, insulation resistance, and GFCI protection
• Test alarm functionality for sash position, airflow disruption, and power failure
• Verify interior lighting, outlets, and blower controls operate reliably

7. Final Certification and Quality Assurance

• Run full performance test cycle and confirm compliance with NSF/ANSI 49 and manufacturer specs
• Document data and generate a detailed service report

Guaranteed Performance from American Instrument Exchange

All refurbished biosafety cabinets from American Instrument Exchange are tested and verified to ensure maximum containment, user protection, and airflow performance. Whether used for microbiology, tissue culture, pharmaceutical compounding, or other work necessitating containment, our BSCs meet industry standards—so your team can work safely and confidently from day one.

Repair and Refurbishment Protocol for Used Biosafety Cabinets

Certified Protection and Performance from American Instrument Exchange

At American Instrument Exchange, every used biosafety cabinet (BSC) we offer is thoroughly repaired and refurbished to meet the highest standards for safety, airflow performance, and compliance. Whether it’s a Class I, Class II Type A2/B2, or Class III unit, we follow a meticulous refurbishment process to ensure your BSC provides reliable containment, sterile workspace conditions, and long-term durability.

Why Choose a Refurbished Biosafety Cabinet from American Instrument Exchange?

  • Fully tested and certified for airflow integrity and containment
  • Backed by warranty and performance guarantee
  • Cost-effective alternative to new biosafety cabinets
  • Environmentally responsible through expert reuse and restoration
  • Serviced by experienced technicians trained in NSF/ANSI 49 protocols

Step-by-Step Refurbishment Protocol

Every biosafety cabinet at American Instrument Exchange undergoes the following comprehensive multi-stage process to ensure it is lab-ready:

1. Initial Intake & Inspection

• Visual inspection of cabinet exterior, control panel, and sash mechanism
• Evaluation of hinges, seals, gaskets, and electrical components
• Missing parts or functional issues are documented for repair

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, disinfectant-safe products
• Decontamination protocols followed to remove biohazardous or chemical residue
• Removable surfaces, work trays, and grilles are cleaned and sanitized

3. Mechanical and Electrical Repair

• Repair or replacement of worn components, including sash latches, lighting, and controls
• Electrical systems including switches, alarms, and outlets are tested and serviced
• Wiring is inspected and repaired to meet safety and performance standards

4. HEPA Filter Evaluation and Replacement

• Filters are tested for integrity using DOP/PAO aerosol challenge testing
• HEPA filters are replaced with OEM or equivalent filters
• Filter seals are verified for leak-free performance

5. Airflow and Performance Testing

• Inflow and downflow velocities are measured using calibrated instruments
• Smoke pattern testing confirms laminar airflow and containment effectiveness
• Blower motor function and airflow uniformity are verified across the cabinet

6. Safety System Verification

• Alarms for airflow disruption, sash height, and power loss are tested
• GFCI protection, lighting, and emergency shutoff systems are confirmed functional

7. Final Quality Control and Certification

• Performance testing is conducted to confirm NSF/ANSI 49 compliance (where applicable)
• Final visual inspection and cleaning performed prior to shipping
• Detailed service report and airflow test results provided with each unit

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the lab equipment industry, American Instrument Exchange is a trusted name in refurbished biosafety cabinets. Our repair and refurbishment protocol ensures each cabinet provides dependable protection for personnel, products, and the environment—delivering maximum safety at a fraction of the cost of new.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.