FiberLite F14-6x250y rotor

Fully Tested & Warrantied*
Brand : Thermo
Product Code : SKU 1392E CENTRI
Title: $0.00
date in: 03-17-2025

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Thermo Scientific Fiberlite F14-6x250y Fixed-Angle Rotor – 6 x 250 mL

The Thermo Scientific Fiberlite F14-6x250y Rotor is a high-speed, fixed-angle carbon fiber centrifuge rotor designed for medium- to large-volume laboratory separations. With capacity for six 250 mL bottles, a total nominal capacity of 1.5 liters, a maximum speed of 14,000 rpm, and maximum relative centrifugal force of approximately 30,240 x g, the F14-6x250y provides an excellent balance of sample volume and centrifugal force for cell harvesting, lysate clarification, tissue homogenate processing, protein precipitation, biomolecule preparation, and other demanding laboratory applications.

Originally manufactured within the Piramoon Technologies Fiberlite rotor family and subsequently supported under Thermo Scientific, the F14-6x250y uses lightweight carbon fiber composite construction instead of conventional aluminum or titanium. Carbon fiber provides excellent strength while resisting corrosion and fatigue, helping reduce rotor weight and simplifying routine handling.

The six-position 250 mL configuration is particularly useful for biotechnology, pharmaceutical, microbiology, molecular biology, protein purification, fermentation, and process-development laboratories that need substantially greater sample capacity than a conventional 50 mL fixed-angle rotor while retaining superspeed centrifugation capability.

This pre-owned Fiberlite F14-6x250y fixed-angle rotor from American Instrument Exchange is inspected and tested prior to shipment and includes a 90-day warranty.

Fiberlite F14-6x250y Key Features

  • High-speed fixed-angle centrifuge rotor

  • 6 x 250 mL capacity

  • 1.5 L total nominal capacity

  • Maximum speed of 14,000 rpm

  • Maximum RCF of approximately 30,240 x g

  • 23° fixed-angle geometry

  • Carbon fiber composite construction

  • Lightweight compared with many conventional metal rotors

  • Excellent corrosion resistance

  • Excellent fatigue resistance

  • Suitable for medium- and large-volume sample processing

  • Excellent for cell harvesting

  • Suitable for lysate and homogenate clarification

  • Useful for protein and enzyme precipitation

  • Suitable for plant tissue homogenates

  • Compatible with selected 250 mL centrifuge bottles

  • Adapter options available for smaller-volume tube formats

  • Biocontainment-capable rotor design in applicable configuration

  • Cold-room compatible

  • Inspected and tested by American Instrument Exchange

  • 90-day warranty included from American Instrument Exchange

Fiberlite F14-6x250y Rotor Overview

The Fiberlite F14-6x250y was developed for laboratories requiring substantial sample capacity together with high centrifugal force.

Each of its six cavities accommodates a compatible 250 mL centrifuge bottle, allowing up to 1.5 liters of nominal sample volume per run.

At its maximum speed of 14,000 rpm, the rotor generates approximately 30,000 x g, placing it well above the centrifugal-force range of many conventional large-capacity swinging-bucket and general-purpose rotors.

This combination makes the F14-6x250y especially attractive for workflows involving larger biological samples that still require efficient pelleting or clarification.

Rather than processing a large culture or homogenate through numerous 50 mL tubes, laboratories can divide material among six 250 mL bottles and process considerably more volume during each centrifugation cycle.

Fiberlite F14-6x250y Key Specifications

Specification Details
Manufacturer Fiberlite / Thermo Scientific
Legacy Manufacturer Piramoon Technologies
Model F14-6x250y
Rotor Type Fixed Angle
Rotor Material Carbon Fiber Composite
Capacity 6 x 250 mL
Total Nominal Capacity 1.5 L
Maximum Speed 14,000 rpm
Maximum RCF Approximately 30,240 x g
Rotor Angle 23°
Maximum Radius Approximately 137–138 mm
Minimum Radius Approximately 37 mm
K-Factor Approximately 1,690–1,700
Maximum Tube Diameter Approximately 60–62 mm
Maximum Tube Length Approximately 120–135 mm, depending on configuration
Construction Carbon Fiber Composite
Corrosion Resistant Yes
Fatigue Resistant Yes
Nominal Bottle Size 250 mL
Biocontainment Applicable sealed configuration
Condition Pre-Owned / Reconditioned
AIE Warranty 90 Days

Important: The Fiberlite F14-6x250y has been manufactured in several centrifuge-specific configurations over its production history. Exact catalog number, drive interface, dimensions, accessories, and centrifuge compatibility should be confirmed from the identification markings on the individual rotor before installation.

Common Applications

The Fiberlite F14-6x250y is well suited for cell harvesting, bacterial and yeast pelleting, biomass recovery, lysate clarification, tissue homogenate processing, subcellular fractionation, ammonium sulfate protein precipitation, enzyme preparation, plant tissue homogenization, biomolecule isolation, and other medium-volume high-speed centrifugation procedures.

Its 1.5-liter nominal capacity makes it particularly useful for workflows in which larger batches must be processed efficiently without sacrificing the centrifugal force available from a superspeed fixed-angle rotor.

Ideal Laboratory Types

The Fiberlite F14-6x250y is an excellent rotor for biotechnology companies, pharmaceutical research laboratories, fermentation laboratories, microbiology facilities, molecular biology groups, protein purification laboratories, plant biology laboratories, university research facilities, contract research organizations, process-development laboratories, and industrial R&D operations.

It is particularly valuable for laboratories moving beyond small-volume 15 mL and 50 mL sample processing into 250 mL batch centrifugation.

6 x 250 mL High-Speed Capacity

The defining advantage of the F14-6x250y is its ability to combine large 250 mL vessels with superspeed centrifugal force.

Six 250 mL positions provide a total nominal capacity of:

1,500 mL per rotor load

For laboratories processing bacterial cultures, yeast cultures, cell suspensions, homogenates, lysates, or precipitated proteins, this can substantially reduce the number of centrifugation cycles required compared with smaller rotors.

For example, processing 1.5 liters using conventional 50 mL tubes could require up to thirty individual tubes.

The F14-6x250y can handle the same nominal volume in six 250 mL bottles.

This can simplify sample preparation, balancing, loading, unloading, and downstream pellet recovery.

14,000 rpm / Approximately 30,000 x g Performance

At maximum speed, the F14-6x250y reaches 14,000 rpm and produces approximately 30,240 x g.

This provides sufficient centrifugal force for many separation procedures that cannot be completed efficiently using standard low-speed bottle rotors.

The combination is especially useful for:

  • Cell pelleting

  • Bacterial harvesting

  • Yeast harvesting

  • Dense biomass recovery

  • Protein precipitation

  • Lysate clarification

  • Homogenate clarification

  • Subcellular fractionation

Actual operating speed should always remain within the lowest permitted rating of the rotor, centrifuge, bottle, closure, adapter, and any other component used in the system.

23° Fixed-Angle Rotor Geometry

The F14-6x250y uses a 23-degree fixed-angle design.

During centrifugation, suspended particles move outward through the sample toward the outer wall and bottom of each vessel.

Compared with many swinging-bucket geometries, the relatively short sedimentation path of a fixed-angle rotor supports efficient pellet formation.

This makes the F14-6x250y especially useful for applications where the primary goal is to:

  • Pellet cells

  • Collect precipitated proteins

  • Clarify lysates

  • Remove tissue debris

  • Harvest microorganisms

  • Separate dense suspended material

After the run, the supernatant can generally be poured or aspirated away while the pellet remains concentrated along the lower outer side of the vessel.

Cell Harvesting & Biomass Recovery

One of the most natural applications for the F14-6x250y is harvesting cells from relatively large culture volumes.

Potential sample types include:

Bacterial cultures
Yeast cultures
Fermentation samples
Compatible cultured-cell suspensions
Microbial biomass

The six 250 mL positions allow larger batches to be processed with fewer individual vessels than would be required with 50 mL tubes.

This can make the rotor particularly useful for protein-expression laboratories, microbiology groups, fermentation research, and biotechnology process development.

Lysate Clarification

After cells have been disrupted, centrifugation is commonly used to separate insoluble cellular debris from soluble proteins, nucleic acids, and other target molecules.

The F14-6x250y's combination of large volume and approximately 30,000 x g maximum RCF makes it well suited for clarification of larger lysate batches.

Rather than dividing a lysate across numerous small tubes, laboratories can process the material in larger compatible 250 mL bottles.

This can be particularly useful during recombinant protein production, biochemical purification, and scale-up studies.

Protein & Enzyme Precipitation

The F14-6x250y is also well suited for ammonium sulfate precipitation and other compatible protein-precipitation workflows.

During ammonium sulfate fractionation, proteins are precipitated from solution according to their solubility characteristics.

Centrifugation is then used to collect the precipitated material.

A six-position 250 mL rotor allows relatively large protein preparations to be processed efficiently, making the F14-6x250y useful for protein purification, enzymology, biochemistry, and pharmaceutical research.

Tissue & Plant Homogenate Processing

Large tissue homogenates can contain substantial quantities of suspended fibers, cell fragments, organelles, and other insoluble material.

The F14-6x250y provides both the vessel volume and centrifugal force required to process these samples effectively.

Potential applications include:

  • Plant tissue homogenates

  • Animal tissue homogenates

  • Agricultural biotechnology

  • Natural-products research

  • Pharmaceutical extraction

  • Food-science research

  • Biochemical fractionation

Its 250 mL vessel format is particularly helpful when sample preparation generates more material than can be conveniently processed in conventional conical tubes.

Carbon Fiber Composite Construction

The F14-6x250y belongs to the Fiberlite family of carbon fiber centrifuge rotors.

Carbon fiber composite provides a very high strength-to-weight ratio and avoids several drawbacks associated with conventional aluminum centrifuge rotors.

Important advantages include:

  • Reduced rotor weight

  • Corrosion resistance

  • Fatigue resistance

  • Easier rotor handling

  • Reduced operator lifting burden

  • Cold-room compatibility

  • Durable high-speed construction

These characteristics contributed to Fiberlite becoming a widely used rotor platform in high-speed laboratory centrifugation.

Corrosion Resistance

Corrosion is one of the major concerns associated with long-term use of traditional aluminum centrifuge rotors.

Moisture, spills, buffers, salts, detergents, and chemical exposure can damage metallic surfaces.

Because a centrifuge rotor experiences very high mechanical stresses during operation, corrosion is more than a cosmetic issue. Significant deterioration can compromise structural integrity.

Fiberlite's carbon fiber composite construction is inherently resistant to the traditional corrosion mechanisms associated with aluminum.

This provides an important durability advantage in laboratories where rotors experience frequent exposure to biological samples, moisture, refrigeration, and cleaning solutions.

Fatigue Resistance

Repeated high-speed operation subjects centrifuge rotors to substantial cyclic mechanical loading.

Every acceleration and deceleration cycle places stress on the rotor body.

Fiberlite carbon composite construction provides excellent resistance to fatigue, helping maintain dimensional stability through repeated operating cycles.

Routine inspection remains essential, however.

Carbon fiber rotors should be examined for evidence of impact, delamination, unusual wear, damaged cavities, drive-interface deterioration, lid problems, or other conditions that could compromise safe operation.

Lightweight Rotor Handling

Large metallic 250 mL centrifuge rotors can be heavy and awkward to remove from a centrifuge chamber.

Carbon fiber construction substantially reduces rotor mass.

This can make the F14-6x250y easier to:

  • Install

  • Remove

  • Transport

  • Clean

  • Inspect

  • Store

For laboratories where rotors are changed frequently, reduced weight can provide an important ergonomic benefit while also reducing the risk of damaging the rotor or centrifuge drive during handling.

250 mL Bottle Compatibility

The F14-6x250y is designed around compatible 250 mL centrifuge bottles.

Depending on the exact rotor configuration, approved bottles can include selected:

  • Polycarbonate bottles

  • PPCO bottles

  • Nalgene bottles

  • Fiberlite bottles

  • Other manufacturer-approved centrifuge vessels

Bottle selection is critical in superspeed centrifugation.

A bottle that physically fits into the rotor cavity is not automatically safe to operate at 14,000 rpm or 30,000 x g.

Laboratories must verify the maximum:

RPM rating
RCF rating
Sample density
Fill volume
Closure requirements
Chemical compatibility

for the specific bottle being used.

Smaller Tube Formats with Adapters

Depending on configuration and available adapters, the F14-6x250 family can also support smaller tube sizes.

Manufacturer documentation for related F14-6x250 configurations identifies adapters for vessel formats including:

  • 85 mL Oak Ridge tubes

  • 50 mL Oak Ridge tubes

  • 30 mL Oak Ridge tubes

  • 16 mL Oak Ridge tubes

  • 15 mL conical tubes

  • Other smaller round-bottom tube formats

This flexibility can allow one rotor to support several different sample-volume ranges.

Only manufacturer-approved or properly validated tube and adapter combinations should be used.

Biocontainment Heritage

The F14-6x250y has documented biocontainment testing within the Fiberlite product family.

The original containment certification identifies a Piramoon Technologies Fiberlite F14-6x250y rotor tested at its maximum 14,000 rpm and demonstrated to contain a spill within the rotor under the specified test method.

For biological laboratories, sealed-rotor capability can provide an important additional layer of protection when processing cell cultures, microorganisms, or other samples capable of producing aerosols.

Biocontainment depends on the entire rotor system, however, including the correct lid, seals, O-rings, vessels, and operating procedures.

Piramoon Technologies & Fiberlite Rotor History

Some F14-6x250y rotors may carry Piramoon Technologies markings, while later documentation and inventory may identify the same Fiberlite product family under Thermo Scientific.

This is not unusual.

Piramoon Technologies was associated with the development and production of Fiberlite carbon fiber centrifuge rotors, and original manufacturer documentation for the F14-6x250y specifically identifies Piramoon Technologies Inc. Fiberlite equipment.

Thermo Scientific subsequently marketed and supported Fiberlite rotors within its centrifuge portfolio.

For this reason, laboratories searching for:

Piramoon F14-6x250y
Fiberlite F14-6x250y
Thermo Fiberlite F14-6x250y

may be looking for rotors from the same broader Fiberlite product lineage.

The exact rotor label, catalog number, and drive interface should always determine compatibility.

F14-6x250y vs. F14-14x50cy

These two Fiberlite rotors emphasize different types of throughput.

The F14-6x250y holds 6 x 250 mL, providing a total nominal capacity of 1.5 liters.

The F14-14x50cy holds 14 x 50 mL, providing 700 mL total nominal capacity.

Choose the F14-6x250y when larger batch volume is the priority.

Choose the F14-14x50cy when the laboratory needs to process a larger number of separate 50 mL samples simultaneously.

Both provide high-speed fixed-angle centrifugation, but their sample formats address distinctly different workflows.

F14-6x250y vs. F20-12x50 LEX

The F20-12x50 LEX prioritizes higher centrifugal force, while the F14-6x250y emphasizes greater sample volume.

The F14-6x250y provides:

6 x 250 mL
1.5 L total capacity
Approximately 30,240 x g

The F20-12x50 LEX provides:

12 x 50 mL
600 mL total capacity
Up to approximately 51,428 x g in a LYNX 6000

For large-volume cell harvesting, lysate clarification, or protein precipitation, the F14-6x250y is generally the better choice.

For smaller-volume separations requiring significantly higher RCF, the F20-12x50 LEX may be preferable.

F14-6x250y vs. Large Swinging-Bucket Rotors

Large-capacity swinging-bucket rotors can offer substantial sample volume and flexible labware options, but they generally operate at lower maximum centrifugal forces than superspeed fixed-angle designs.

The F14-6x250y reaches approximately 30,000 x g, making it particularly effective for pelleting and clarification.

A swinging-bucket rotor may be preferable for:

  • Density gradients

  • Horizontal separation interfaces

  • Microplates

  • Blood tubes

  • Specialty bucket-based labware

The F14-6x250y is better optimized for rapid sedimentation and pellet formation in larger-volume bottles.

Centrifuge Compatibility

One important consideration with the F14-6x250y is that Fiberlite produced multiple centrifuge-specific versions and drive configurations.

F14-6x250-series rotors have appeared in configurations associated with several generations of laboratory centrifuges.

Depending on the exact rotor catalog number and drive interface, compatible systems may include certain:

  • Thermo Scientific centrifuges

  • Sorvall centrifuges

  • LYNX-series centrifuges

  • Legacy RC-series centrifuges

  • Other superspeed centrifuge platforms

The model name alone should never be used as the sole basis for determining compatibility.

Before purchasing or installing a used rotor, confirm:

  1. Rotor model

  2. Rotor catalog or part number

  3. Drive interface

  4. Centrifuge model

  5. Maximum permitted rotor speed in that centrifuge

  6. Compatible lid and accessories

American Instrument Exchange can help buyers determine compatibility between a specific rotor and centrifuge before purchase.

Legacy F14-6x250 Versions vs. Current Fiberlite Rotors

Fiberlite has produced several generations of 6 x 250 mL carbon fiber rotors.

Although they may share similar names and capacities, differences can include:

  • Centrifuge drive interface

  • Catalog number

  • Rotor lid

  • Auto-ID capability

  • Maximum permitted speed

  • Maximum RCF

  • Accessories

  • Bottle compatibility

A newer LYNX-compatible F14-6x250y should not automatically be assumed interchangeable with an older Piramoon or legacy Sorvall configuration.

This is especially important when purchasing a replacement rotor for an existing centrifuge.

Rotor Inspection & Testing by American Instrument Exchange

Centrifuge rotors are safety-critical components, so American Instrument Exchange carefully evaluates pre-owned rotors before offering them for laboratory use.

Inspection of the Fiberlite F14-6x250y may include evaluation of:

  • Carbon fiber rotor body

  • Tube cavities

  • Drive interface

  • Rotor lid

  • Locking mechanism

  • O-rings and seals

  • Identification markings

  • Signs of impact

  • Signs of delamination

  • Abnormal wear

  • Overall mechanical condition

Whenever possible, the rotor is installed in a compatible centrifuge and operated to verify proper fit and performance.

Users should continue to inspect all centrifuge rotors before operation and follow appropriate manufacturer guidance regarding cleaning, maintenance, operating limits, and service life.

Refurbished Fiberlite Rotors from American Instrument Exchange

American Instrument Exchange offers inspected used and refurbished centrifuge rotors for laboratories seeking to expand existing centrifuge capabilities without the cost of purchasing new accessories.

The Fiberlite F14-6x250y is particularly useful for laboratories requiring high-speed processing of medium- to large-volume samples in the convenient 250 mL bottle format.

American Instrument Exchange stocks Fiberlite, Thermo Scientific, Sorvall, Beckman Coulter, Eppendorf, and other centrifuge rotors as well as complete refrigerated, superspeed, and ultracentrifuge systems.

Shipping & Rotor Care

The Fiberlite F14-6x250y should be carefully packaged during transport to protect the carbon fiber body, drive interface, lid, and sealing surfaces.

After delivery, users should inspect the rotor and verify its exact identification and centrifuge compatibility before placing it into service.

Only compatible cleaning and decontamination methods should be used.

Avoid abrasive materials, inappropriate chemicals, mechanical impacts, and unapproved sterilization procedures.

The rotor body, lid, O-rings, tube cavities, and drive interface should be inspected regularly and maintained according to applicable manufacturer recommendations.

Related Laboratory Equipment

Laboratories using an F14-6x250y rotor frequently also require superspeed centrifuges, 250 mL centrifuge bottles, 50 mL fixed-angle rotors, swinging-bucket rotors, refrigerated benchtop centrifuges, ultracentrifuges, biosafety cabinets, laboratory refrigerators, ultra-low freezers, incubators, shakers, and other sample-processing equipment.

American Instrument Exchange offers refurbished centrifuges and centrifuge accessories for biotechnology, pharmaceutical, microbiology, molecular biology, academic, process-development, and industrial laboratories.

Fiberlite F14-6x250y Frequently Asked Questions

What is the capacity of the Fiberlite F14-6x250y?

The rotor accommodates six 250 mL bottles, providing a total nominal capacity of 1.5 liters per run.

What is the maximum speed of the F14-6x250y?

The applicable high-speed F14-6x250y configuration is rated for up to 14,000 rpm.

What is the maximum RCF?

Maximum relative centrifugal force is approximately 30,240 x g, depending on the exact rotor configuration and centrifuge.

What type of rotor is the F14-6x250y?

It is a 23-degree fixed-angle carbon fiber composite centrifuge rotor.

What is the rotor commonly used for?

Typical applications include cell harvesting, bacterial and yeast pelleting, lysate clarification, tissue homogenate processing, protein and enzyme precipitation, biomass recovery, and other high-speed medium-volume separations.

Why does this rotor sometimes appear under the Piramoon name?

Original Fiberlite documentation identifies certain F14-6x250y rotors as manufactured by Piramoon Technologies Inc. Later versions and documentation appear under Thermo Scientific's Fiberlite product line.

For replacement purposes, the specific rotor's part number and drive configuration are more important than the brand name printed in an online listing.

Is the Piramoon F14-6x250y the same as a Thermo Fiberlite F14-6x250y?

They belong to the same broader Fiberlite rotor lineage, but individual versions should not automatically be assumed interchangeable. Catalog number, drive interface, centrifuge compatibility, and operating limits must be checked.

Can the F14-6x250y be used in a Thermo LYNX centrifuge?

Certain F14-6x250y configurations are designed for LYNX centrifuges. Other legacy versions were manufactured for different centrifuge platforms.

The specific rotor identification number should be confirmed before installation.

Is the F14-6x250y compatible with older Sorvall centrifuges?

Certain legacy F14-6x250y configurations were designed for Sorvall superspeed centrifuges. Compatibility depends on the precise drive interface and rotor catalog number.

Can any 250 mL bottle be used?

No. A bottle should only be used when its dimensions, material, closure, sample density, maximum rpm, and maximum RCF are appropriate for the rotor and application.

Physical fit alone does not establish safe compatibility.

Can smaller tubes be used?

Yes, selected smaller tube sizes can be used with compatible manufacturer-approved adapters. Adapter availability varies with the exact rotor version.

Can the F14-6x250y be used for harvesting bacterial cultures?

Yes. Its 1.5-liter capacity and approximately 30,000 x g maximum force make it particularly useful for bacterial and microbial cell harvesting.

Is it useful for protein purification?

Yes. The rotor can be used for lysate clarification, precipitate recovery, ammonium sulfate protein precipitation, and other centrifugation steps commonly encountered during protein-purification workflows.

What advantage does carbon fiber provide?

Carbon fiber provides a high strength-to-weight ratio together with excellent resistance to corrosion and fatigue. It also makes large rotors easier to handle than many comparable metallic designs.

Is the F14-6x250y biocontainment capable?

Certain sealed F14-6x250y configurations have documented biocontainment testing. Proper lids, seals, approved vessels, and appropriate operating procedures are required to maintain containment.

How does the F14-6x250y compare with the F14-14x50cy?

The F14-6x250y provides 1.5 L total capacity in six 250 mL bottles, while the F14-14x50cy processes fourteen independent 50 mL samples totaling 700 mL. Choose the F14-6x250y for larger batch volumes and the F14-14x50cy for greater individual sample throughput.

How does American Instrument Exchange test used Fiberlite rotors?

American Instrument Exchange inspects fixed-angle rotor bodies for physical integrity, examines lids, seals, drive components, and identification markings, and whenever possible operates the rotor in a compatible centrifuge to confirm proper fit and performance.

What warranty is included?

This pre-owned Fiberlite F14-6x250y rotor includes a 90-day warranty from American Instrument Exchange.

Testing Procedures for Used and Refurbished Laboratory Centrifuges

Ensure Quality, Accuracy, and Compliance Before Deployment

Used and refurbished laboratory centrifuges from American Instrument Exchange undergo testing procedures to ensure they meet the performance, safety, and compliance standards required in modern laboratories.

Why Testing Used Laboratory Centrifuges Is Essential

Before a centrifuge is reintroduced into a lab environment, it must be tested for:

  • Mechanical integrity
  • Rotor balance and speed accuracy
  • Safety system functionality
  • Electrical compliance

Proper testing helps extend equipment lifespan, reduce downtime, and ensure safety in high-stakes lab environments such as clinical diagnostics, biotechnology, and research applications.

Our structured testing protocol for used and refurbished centrifuges ensures equipment safety, accuracy, and longevity.

Key Testing Procedures for Refurbished and Used Centrifuges

1. Initial Visual Inspection

  • Check for signs of wear, corrosion, or damage to housing, lid, and control panels
  • Inspect power cords, plugs, and connectors for fraying or exposed wiring
  • Confirm that the rotor and accessories are compatible and undamaged

2. Functional Testing

  • Power up the centrifuge and confirm successful boot-up of digital or analog displays
  • Test lid lock and emergency stop mechanisms
  • Run initial cycles at various speeds to check for abnormal noise or vibration

3. Rotor and Speed Verification

  • Test all programmable speed settings to confirm consistent acceleration and deceleration
  • Monitor temperature, vibration, and RPM consistency throughout the cycle
  • Balance testing ensures smooth operation and prevents wear on internal components

4. Electrical Safety and Grounding Tests

  • Verify that all electrical components are properly grounded and shielded

5. Temperature Control (if applicable)

  • For refrigerated centrifuges, test cooling function to ensure temperature stability within set ranges
  • Check refrigerant levels and inspect for compressor noise or failure

6. Final Quality Assurance Checklist

  • Conduct a full run-through using the user interface
  • Document all test results

Repair and Refurbishment Protocol for Used Laboratory Centrifuges

Certified Quality from American Instrument Exchange

At American Instrument Exchange, we follow a meticulous repair and refurbishment protocol to ensure that every used laboratory centrifuge we sell. We strive for reliable performance and long-term durability—providing labs with exceptional value on high-quality pre-owned centrifuges.

Why Choose a Refurbished Centrifuge from American Instrument Exchange?

  • Fully tested
  • Backed by warranty and performance guarantee
  • Cost-effective alternative to new lab equipment
  • Environmentally responsible through equipment reuse
  • Supported by expert technicians with decades of experience

Step-by-Step Refurbishment Protocol

Every used centrifuge at American Instrument Exchange goes through the following comprehensive repair and refurbishment process:

1. Initial Intake & Inspection

  • Our technicians perform a complete visual and mechanical inspection
  • Evaluation of hinges, seals, gaskets, and electrical components
  • Any physical damage, missing parts, or wear is documented for repair

2. Cleaning and decontamination

  • Full internal and external cleaning using non-abrasive, disinfectant-safe products
  • Biological or chemical residue is decontaminated/cleaned

3. Mechanical & Electrical Repairs

  • Damaged or worn parts (e.g., drive motors, lid latches, rotor buckets) are replaced or repaired
  • Electrical components, sensors, and fuses are tested and replaced as needed
  • Wiring is inspected for integrity and safety per industry standards

4. Rotor & Accessory Evaluation

  • All rotors, buckets, and adapters are inspected for cracks, corrosion, and balance
  • Non-conforming components are replaced with OEM or equivalent alternatives

5. Performance Testing

  • Rotor speed (RPM), acceleration, and deceleration are verified
  • Refrigerated centrifuges undergo temperature stability testing across set ranges

6. Safety System Verification

  • Lid lock and interlock systems are tested for proper function
  • Emergency stop and imbalance detection systems are verified
  • Electrical safety and grounding tests are conducted

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the industry, American Instrument Exchange is a trusted name for refurbished lab equipment. Our centrifuge refurbishment protocol reflects our commitment to quality, safety, and customer satisfaction.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.