Thermo 3307 SteriCult incubator
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Successful cell culture depends on more than maintaining the correct temperature and CO₂ concentration. Protecting valuable cultures from airborne contamination while providing a stable incubation environment is equally important, particularly when working with primary cells, stem cells, hybridomas, or long-term research projects. The Thermo Steri-Cult 3307 CO₂ Incubator was engineered with contamination control as a primary design objective, combining Class 100 HEPA-filtered air quality, a 140°C in-place sterilization cycle, and precise environmental regulation within a compact 8.2 cubic foot (232-liter) chamber.
This refurbished unit from American Instrument Exchange has also been upgraded with a new dual-beam infrared (IR) CO₂ sensor, providing improved CO₂ measurement compared with the original thermal conductivity configuration. Infrared sensing delivers accurate atmospheric control with reduced sensitivity to chamber humidity, making the incubator an excellent choice for demanding mammalian cell culture applications requiring long-term environmental stability.
Approximately 8.2 cu. ft. (232 L) chamber capacity
Upgraded dual-beam infrared (IR) CO₂ sensor
CO₂ control from 0% to 20%
Temperature range from ambient +5°C to 50°C
Class 100 in-chamber HEPA filtration
Automatic 140°C sterilization cycle
Controlled humidity to 95% RH
Stainless steel chamber interior
Heated inner glass door
Digital microprocessor controls
LED display
Up to 22 adjustable shelf positions
Audible and visual alarms
Remote alarm contacts
Interior accessory outlet
90-day warranty from American Instrument Exchange
The Thermo Steri-Cult 3307 was developed for laboratories where maintaining sterile culture conditions is as important as controlling temperature and CO₂. Rather than relying solely on routine cleaning procedures, the incubator continuously filters recirculated chamber air through a high-efficiency HEPA filter while providing a programmable high-temperature sterilization cycle that simplifies decontamination between research projects.
The compact chamber accommodates tissue culture flasks, Petri dishes, multiwell plates, spinner flasks, and other commonly used cell culture vessels while providing enough capacity for multiple investigators or independent research projects. Up to 22 adjustable shelf positions allow laboratories to configure the chamber for different vessel heights and maximize usable incubation space.
The upgraded infrared CO₂ sensor further improves long-term environmental stability by providing dependable CO₂ measurement that is largely unaffected by changes in chamber humidity. Combined with controlled humidity and precise temperature regulation, the Steri-Cult 3307 creates a reliable environment for maintaining sensitive mammalian cell cultures over extended incubation periods.
The Thermo Steri-Cult 3307 is commonly used for:
Mammalian cell culture
Primary cell culture
Stem cell research
Cancer biology
Hybridoma production
Tissue engineering
Virology research
Protein expression
Monoclonal antibody development
Pharmaceutical research
Biotechnology research
Clinical laboratory research
Academic life science research
Long-term maintenance of valuable cell lines
Its combination of HEPA filtration, infrared CO₂ sensing, and automated sterilization makes it particularly valuable for laboratories where contamination prevention is a top priority.
The Thermo Steri-Cult 3307 is well suited for biotechnology companies, pharmaceutical laboratories, university research facilities, hospital research centers, government laboratories, and contract research organizations performing routine mammalian cell culture.
Its compact footprint makes it an excellent solution for laboratories requiring advanced contamination control without dedicating space to a larger reach-in incubator. It is equally appropriate as a primary incubator for smaller laboratories or as a dedicated incubator for sensitive cell lines requiring additional isolation.
The Thermo Steri-Cult 3307 maintains temperatures from 5°C above ambient to 50°C using a microprocessor-controlled heating system designed to deliver excellent temperature stability and chamber uniformity. Controlled relative humidity of up to 95% RH helps minimize evaporation of cell culture media, preserving consistent osmolarity during long incubation periods.
The upgraded dual-beam infrared CO₂ sensor accurately regulates CO₂ concentrations from 0% to 20%, while the heated inner glass door reduces condensation and allows researchers to inspect cultures without exposing the entire chamber to ambient laboratory conditions. Together, these systems provide rapid recovery following door openings while maintaining a stable environment for sensitive cell culture applications.
One of the defining advantages of the Steri-Cult 3307 is its layered approach to contamination prevention. During normal operation, an in-chamber HEPA filtration system continuously removes airborne particulates to maintain Class 100 air quality, helping protect cultures from contaminants introduced during routine laboratory use.
When periodic decontamination is required, the incubator's 140°C in-place sterilization cycle sanitizes internal chamber surfaces without extensive manual disassembly. Access-code protection prevents accidental activation, while integrated safety monitoring helps ensure reliable operation throughout the sterilization process. Combined with the polished stainless steel interior and removable chamber components, these features simplify routine maintenance while supporting reproducible cell culture over the long term.
With approximately 8.2 cubic feet (232 liters) of usable chamber space, the Thermo Steri-Cult 3307 provides ample capacity for routine mammalian cell culture while maintaining a compact laboratory footprint. The chamber accommodates T-flasks, culture dishes, multiwell plates, spinner flasks, cell culture bags, roller bottles, and other commonly used tissue culture vessels, making it well suited for research laboratories managing multiple cell lines simultaneously.
The adjustable shelving system allows users to configure the interior for a variety of vessel sizes while preserving adequate airflow throughout the chamber. To maintain consistent temperature, humidity, and CO₂ conditions, culture vessels should be spaced evenly and should not obstruct air circulation. Proper organization also helps reduce unnecessary door openings, improving environmental stability during long-term incubation.
Many laboratories dedicate individual shelves or sections of the incubator to specific cell lines, investigators, or research projects. This organization minimizes handling, reduces cross-contamination risk, and streamlines daily laboratory workflows.
The Thermo Steri-Cult 3307 was engineered for continuous operation in research laboratories where dependable environmental control is required every day. Its insulated cabinet construction, digital microprocessor controls, and efficient heating system work together to maintain stable incubation conditions while minimizing unnecessary energy consumption.
The in-chamber Class 100 HEPA filtration system continuously cleans recirculated air without requiring excessive airflow, helping maintain a clean incubation environment while supporting efficient operation. The heated inner glass door reduces condensation and allows researchers to inspect cultures before opening the chamber, limiting temperature and CO₂ loss during routine observation.
The integrated 140°C sterilization cycle also helps reduce routine maintenance requirements by simplifying chamber decontamination. Rather than relying exclusively on manual cleaning procedures, laboratories can periodically perform automated sterilization between projects, improving laboratory efficiency while helping protect valuable cultures from contamination.
| Specification | Details |
|---|---|
| Manufacturer | Thermo |
| Model | Steri-Cult 3307 |
| Incubator Type | Water-Jacketed CO₂ Incubator |
| Chamber Capacity | Approximately 232 L (8.2 cu. ft.) |
| Temperature Range | Ambient +5°C to 50°C |
| CO₂ Range | 0% to 20% |
| CO₂ Sensor | Dual-Beam Infrared (IR) |
| Humidity Control | Up to 95% Relative Humidity |
| Air Quality | Class 100 HEPA Filtration |
| Sterilization | Automatic 140°C In-Place Sterilization Cycle |
| Chamber Material | Stainless Steel |
| Door Configuration | Heated Inner Glass Door with Insulated Outer Door |
| Controller | Digital Microprocessor |
| Display | LED Digital Display |
| Shelf Positions | Up to 22 |
| Alarm System | Audible, Visual, and Remote Alarm Contacts |
| Interior Accessory Outlet | Yes |
| Electrical Requirements | 120 V |
| Approximate Weight | Approximately 375 lb |
Specifications are believed to be accurate but may vary depending on factory-installed options and the upgraded infrared CO₂ sensor installed on this unit. Please verify all specifications prior to purchase.
This refurbished unit has been upgraded with a dual-beam infrared CO₂ sensor, providing more accurate CO₂ measurement than the original thermal conductivity sensor. Combined with Class 100 HEPA filtration and the integrated sterilization cycle, it offers enhanced environmental control for contamination-sensitive cell culture applications.
Infrared sensors provide highly accurate CO₂ measurement and are largely unaffected by humidity changes inside the chamber. This results in faster recovery following door openings and more stable atmospheric conditions for sensitive mammalian cell cultures.
The HEPA filtration system continuously cleans recirculated chamber air, removing airborne particles that could contribute to contamination. Maintaining Class 100 air quality helps protect valuable cell cultures during routine laboratory operation.
The automatic sterilization cycle heats the chamber to approximately 140°C, reducing microbial contamination on interior surfaces without requiring extensive manual cleaning or chamber disassembly. Routine sterilization helps maintain a cleaner incubation environment between research projects.
The Steri-Cult 3307 is frequently found in biotechnology companies, pharmaceutical research laboratories, universities, hospital research centers, and government laboratories performing mammalian cell culture, stem cell research, cancer biology, virology, and tissue engineering.
Yes. The combination of stable temperature control, precise infrared CO₂ regulation, controlled humidity, HEPA-filtered chamber air, and integrated sterilization makes the incubator an excellent choice for maintaining valuable cell cultures over extended periods.
Yes. The chamber provides sufficient capacity for multiple investigators while the adjustable shelving system allows cultures to be organized by project or cell line. Proper organization and routine sterilization help maintain efficient workflows and reduce contamination risks in shared laboratory environments.
Purchasing a refurbished Thermo Steri-Cult 3307 from American Instrument Exchange provides laboratories with an advanced CO₂ incubator featuring an upgraded infrared CO₂ sensor, Class 100 HEPA filtration, and automated sterilization at substantial savings compared with buying new equipment. Every incubator is inspected and tested prior to shipment and includes a 90-day warranty, providing confidence that it is ready to support demanding cell culture research.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.