The Thermo CryoPlus 2 Liquid Nitrogen Storage System is designed for secure cryogenic storage of biological samples, cell lines, stem cells, reproductive materials, tissue samples, and other valuable laboratory specimens. Utilizing liquid nitrogen temperatures for long-term preservation, the CryoPlus 2 provides dependable sample storage for biotechnology companies, pharmaceutical manufacturers, fertility clinics, research laboratories, biobanks, and academic institutions. This refurbished Thermo CryoPlus 2 from American Instrument Exchange offers a cost-effective alternative to new cryogenic storage systems while providing the reliability required for critical sample preservation applications.
The Thermo CryoPlus 2 is engineered for laboratories and facilities requiring dependable cryogenic storage conditions for irreplaceable biological materials. Designed around a vacuum-insulated storage vessel, the CryoPlus 2 maintains ultra-low temperatures using liquid nitrogen while minimizing nitrogen consumption. The integrated monitoring system continuously tracks liquid nitrogen levels and operating conditions, helping protect valuable samples through audible and visual alarm functions. Cryogenic storage systems such as the CryoPlus 2 are commonly used when long-term preservation requirements exceed the capabilities of conventional ultra-low temperature freezers, providing storage temperatures approaching -196°C.
The Thermo CryoPlus 2 is commonly used for storage of stem cells, cell cultures, tissue samples, DNA libraries, reproductive materials, embryos, sperm samples, ovarian tissue, microbial cultures, blood components, and other biological specimens requiring cryogenic preservation. Liquid nitrogen storage systems are widely used in biotechnology research, pharmaceutical development, regenerative medicine, fertility treatment programs, clinical research, and biobanking operations where sample viability must be maintained over extended periods.
This cryogenic storage system is well suited for biotechnology companies, pharmaceutical laboratories, stem cell research facilities, fertility clinics, tissue banks, biorepositories, academic research institutions, hospital research centers, and clinical laboratories. Facilities utilizing biosafety cabinets, ultra-low freezers, centrifuges, and incubators often rely on liquid nitrogen storage systems such as the CryoPlus 2 to support long-term sample preservation programs.
|
Specification |
Details |
|
Manufacturer |
Thermo Scientific |
|
Model |
CryoPlus 2 |
|
Equipment Type |
Liquid Nitrogen Storage System |
|
Storage Method |
Liquid Nitrogen Cryogenic Storage |
|
Operating Temperature |
Approximately -196°C |
|
Construction |
Vacuum Insulated Cryogenic Vessel |
|
Control System |
Microprocessor Controlled |
|
Display |
Digital Monitoring Display |
|
Alarm System |
Audible and Visual Alarms |
|
Nitrogen Monitoring |
Automatic Level Monitoring |
|
Application |
Long-Term Biological Sample Preservation |
|
Condition |
Refurbished |
Specifications compiled from Thermo Scientific manufacturer literature, distributor technical references, and American Instrument Exchange product information.
At American Instrument Exchange, each refurbished cryogenic storage system is inspected and evaluated by our technicians prior to shipment. Testing procedures may include controller operation verification, display functionality testing, alarm system evaluation, lid and seal inspection, physical vessel inspection, monitoring system assessment, and general operational testing. Components showing excessive wear are addressed as needed to help ensure reliable operation. Final cleaning and inspection are completed before packaging and shipment.
The Thermo CryoPlus 2 should be installed in a well-ventilated area suitable for liquid nitrogen storage applications. Buyers should verify facility requirements for liquid nitrogen supply, oxygen monitoring systems where applicable, and safe handling procedures for cryogenic materials. Adequate space should be provided around the unit for sample access and routine maintenance. The vessel should be transported and installed in accordance with accepted cryogenic equipment handling practices.
Laboratories purchasing liquid nitrogen storage systems often also require ultra-low freezers, laboratory refrigerators, biosafety cabinets, centrifuges, and incubators. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support sample preparation, cold storage, cryogenic preservation, and research workflows.
| Exterior dimensions | 28.5”W x 34.0”D x 41.0”H (with closed lid) |
| Interior dimensions | 24” dia. x 27.5”H |
| Static evaporation rate | 5 days |
| Static holding time | 40 days |
| Weight | 325 lbs |
| Electrical requirements | 100 - 120V, 50/60 Hz |
For inquiries about the Thermo Scientific CryoPlus 2 Liquid Nitrogen Freezer, please give us a call at 978-521-2221, or fill out the form on this page.
The Thermo CryoPlus 2 is a liquid nitrogen (LN₂) cryogenic storage system designed for long-term preservation of biological samples at ultra-low temperatures. It is commonly used in research laboratories, biobanks, clinical labs, and pharmaceutical facilities to store materials such as cell cultures, stem cells, tissue samples, and DNA libraries.
The system uses liquid nitrogen to maintain extremely cold conditions in either liquid phase or vapor phase storage, helping preserve biological integrity for extended periods.
The system maintains cryogenic temperatures using liquid nitrogen stored inside a vacuum-insulated stainless-steel chamber. The LN₂ gradually evaporates, keeping the internal environment extremely cold.
The CryoPlus series includes microprocessor-controlled autofill capability, which automatically replenishes liquid nitrogen from a supply tank when levels drop below preset thresholds.
This automated refill system helps maintain consistent storage temperatures while reducing manual maintenance.
The CryoPlus 2 is commonly used to store a wide variety of cryogenically preserved materials, including:
Cryogenic storage systems like the CryoPlus 2 are especially important for long-term sample preservation in biobanking and molecular biology research.
Compared with traditional manual-fill cryogenic tanks, the CryoPlus 2 provides several operational advantages:
These features make the CryoPlus series suitable for laboratories that require reliable long-term cryogenic storage with minimal manual intervention.
Cryogenic storage systems can store samples in either liquid nitrogen (liquid phase) or nitrogen vapor (vapor phase).
Liquid phase storage
Vapor phase storage
Many laboratories prefer vapor-phase storage for clinical samples and biobanking applications.
Evaporation rate refers to how quickly liquid nitrogen naturally boils off from a storage vessel.
Typical evaporation rates range from 2 to 10 liters per day depending on:
Lower evaporation rates indicate more efficient cryogenic insulation.
Many modern cryogenic storage systems include remote alarm contacts and monitoring capabilities.
These features allow laboratories to:
Remote monitoring helps protect valuable biological samples.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.