Mettler Toledo XPE1202S Precision Balance

Fully Tested & Warrantied*
Brand : Mettler
Product Code : SKU 0664U BALANCE
Color: $2200.00
Size: 08-28-2023

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Mettler Toledo XPE1202S Precision Balance – Used & Refurbished

The Mettler Toledo XPE1202S Precision Balance is a high-performance laboratory balance designed for applications that require a combination of 1210 g maximum capacity and 0.01 g readability. Part of Mettler Toledo's Excellence Plus series, the XPE1202S combines fast MonoBloc weighing technology, SmartPan stabilization, automatic internal adjustment, touchscreen operation, and advanced workflow features in a compact precision-balance format.

Available used and refurbished from American Instrument Exchange, the Mettler Toledo XPE1202S is well suited for pharmaceutical, biotechnology, chemical, formulation, research, and quality-control laboratories performing reagent preparation, formulation, component weighing, sample preparation, and other quantitative procedures.

Each balance is inspected, cleaned, calibrated, and tested for weighing performance before shipment and includes a 90-day warranty from American Instrument Exchange.

Key Features

  • 1210 g maximum weighing capacity

  • 10 mg / 0.01 g readability

  • Repeatability limit of 8 mg / 0.008 g

  • Typical repeatability of approximately 4 mg / 0.004 g

  • Linearity deviation limit of 20 mg / 0.02 g

  • Typical USP minimum weight of approximately 12 g

  • Typical minimum weight of approximately 800 mg at U=1%, k=2

  • Rapid 1.2-second settling time

  • MonoBloc HighSpeed weighing technology

  • SmartPan weighing platform

  • Automatic internal adjustment

  • Large color touchscreen interface

  • StatusLight balance-ready indicator

  • Built-in GLP/GMP-oriented workflow features

  • Multiple weighing applications

  • Advanced data connectivity

  • Used, refurbished, calibrated, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Mettler Toledo XPE1202S is designed for laboratories that need substantially finer resolution than a conventional 0.1 g toploading balance while maintaining enough capacity for routine sample-preparation and formulation work.

Its 1210 g capacity and 0.01 g readability allow users to weigh samples ranging from relatively small reagent quantities to containers and preparations weighing more than one kilogram.

That makes the XPE1202S particularly versatile.

It can perform routine sample and reagent weighing, but it also provides enough resolution for more demanding quantitative work where hundredth-of-a-gram differences are significant.

The Excellence Plus platform adds a number of workflow-oriented features not typically found on basic precision balances, including touchscreen control, automatic internal adjustment, StatusLight balance monitoring, SmartPan technology, and electronic data handling.

For laboratories that need dependable 10 mg resolution without moving to the greater environmental sensitivity of an analytical balance, the XPE1202S offers a useful middle ground.

Common Applications

The Mettler Toledo XPE1202S is well suited for reagent preparation, formulation, sample preparation, component weighing, quality control, percentage weighing, check weighing, solution preparation, ingredient weighing, and general quantitative laboratory work.

Pharmaceutical and biotechnology laboratories can use the balance for formulation ingredients, buffers, media components, reagents, and research samples.

Chemical laboratories can use the XPE1202S for solution preparation, compound weighing, mixture preparation, and quantitative research procedures.

Food and beverage, cosmetics, materials science, environmental, and quality-control laboratories can also use the balance for ingredient measurement, product development, sample preparation, and routine testing.

Its 1210 g capacity is especially practical when weighing into bottles, beakers, flasks, and other laboratory containers whose tare weight must be accommodated along with the sample.

Ideal Laboratory Types

The XPE1202S is a strong choice for pharmaceutical, biotechnology, chemical, formulation, food and beverage, cosmetics, materials science, academic, environmental, and quality-control laboratories.

It is particularly useful in facilities that need better resolution than a standard 0.1 g balance but do not require analytical-balance resolution.

A laboratory routinely working with samples in the tens to hundreds of grams may find 0.01 g readability to be an ideal compromise between measurement resolution and ease of use.

The XPE1202S can therefore serve as a primary precision balance or as a complement to an analytical balance used for smaller and more demanding measurements.

Precision Weighing Performance

The Mettler Toledo XPE1202S provides 10 mg, or 0.01 g, readability throughout its 1210 g weighing range.

Mettler Toledo specifies a repeatability limit of 8 mg, with typical repeatability of approximately 4 mg under appropriate conditions.

Linearity deviation is specified at 20 mg, while the balance provides a typical settling time of approximately 1.2 seconds.

This combination provides rapid and consistent measurements for routine quantitative laboratory work.

The XPE1202S therefore offers substantially finer resolution than a 0.1 g toploading balance while remaining fast enough for repetitive sample-preparation and formulation procedures.

Minimum Sample Weight & USP Applications

Mettler Toledo specifies a typical USP minimum sample weight of approximately 12 g for the XPE1202S under stated reference conditions.

The manufacturer also specifies a typical minimum weight of approximately 800 mg at U=1%, k=2.

These figures highlight the distinction between readability and minimum sample weight.

Although the XPE1202S displays measurements in 0.01 g increments, quantitative weighing procedures require a sufficiently large sample to maintain the laboratory's required level of measurement uncertainty.

Actual minimum weight depends on repeatability, environmental conditions, installation quality, calibration status, and the performance of the individual balance.

For USP, GMP, GLP, or other controlled applications, laboratories should establish minimum weight according to the installed balance and the uncertainty requirements of the procedure.

Controlling Drafts, Vibration & Environmental Influences

The XPE1202S provides relatively fine 10 mg resolution, so environmental conditions can influence weighing performance.

Vibration, unstable work surfaces, strong airflow, temperature changes, and incorrect leveling can increase measurement variation.

The balance should be installed on a rigid, stable, level work surface away from major vibration sources such as centrifuges, shakers, pumps, and compressors.

Mettler Toledo's SmartPan technology helps reduce the influence of air movement on the weighing cell.

By limiting turbulence around the sample and weighing pan, SmartPan can improve stabilization and repeatability without requiring the fully enclosed draft shield typically associated with analytical balances.

This makes the XPE1202S easier to use in routine laboratory environments while still supporting relatively high precision.

Calibration & Automatic Internal Adjustment

The XPE1202S incorporates automatic internal adjustment, allowing the balance to compensate for changes that could otherwise influence weighing performance.

Internal reference weights eliminate the need for operators to perform routine adjustment manually with external weights.

This is particularly useful in busy laboratories where the balance may be used throughout the day by multiple technicians.

Automatic internal adjustment does not eliminate the need for independent performance verification.

Laboratories operating under GLP, GMP, USP, ISO, or internal quality procedures may still require scheduled checks using appropriate traceable external calibration weights.

American Instrument Exchange calibrates and evaluates refurbished XPE1202S balances before shipment and verifies the internal adjustment system as part of the testing process.

SmartPan & Fast Stabilization

The XPE1202S incorporates Mettler Toledo's SmartPan weighing technology, designed to reduce the effect of air movement on the weighing result.

At 0.01 g readability, even relatively small environmental disturbances can influence stabilization.

SmartPan reduces turbulence around the weighing area, helping the balance achieve stable results more quickly.

The manufacturer specifies an approximately 1.2-second settling time, making the XPE1202S particularly useful for repetitive weighing procedures.

For technicians weighing multiple samples or adding ingredients sequentially during formulation, rapid stabilization can significantly improve workflow efficiency.

Touchscreen Operation & StatusLight

The Excellence Plus platform incorporates a large touchscreen interface that provides direct access to weighing functions, applications, settings, and results.

The touchscreen simplifies navigation compared with older keypad-driven laboratory balances and allows users to configure commonly performed procedures more efficiently.

Mettler Toledo's StatusLight provides a simple visual indication of balance condition.

A green status indicates that the balance is ready for weighing, while warning and error conditions are displayed using different colors.

This provides operators with an immediate indication of balance readiness before critical measurements are taken.

Built-In Applications & Data Management

The XPE1202S supports multiple weighing applications beyond basic mass determination.

Depending on configuration, users can perform procedures such as percentage weighing, piece counting, formulation, statistics, dynamic weighing, density determination, differential weighing, and check weighing.

Electronic data connectivity allows weighing results to be transferred to compatible computers, printers, and laboratory systems.

Direct electronic transfer reduces manual transcription and can help laboratories maintain more consistent documentation.

For GLP- and GMP-oriented laboratories, these features can support more standardized and traceable weighing procedures.

Key Specifications

Specification Mettler Toledo XPE1202S
Balance Type Precision / Toploading Balance
Maximum Capacity 1210 g
Readability 10 mg / 0.01 g
Repeatability Limit 8 mg / 0.008 g
Typical Repeatability Approx. 4 mg / 0.004 g
Linearity Deviation 20 mg / 0.02 g
Typical USP Minimum Weight Approx. 12 g
Typical Minimum Weight (U=1%, k=2) Approx. 800 mg
Settling Time Approx. 1.2 seconds
Adjustment Internal / automatic
Weighing Technology MonoBloc HighSpeed
Weighing Pan Approx. 170 × 205 mm
Overall Dimensions Approx. 194 mm W × 392 mm D × 96 mm H
Pan Technology SmartPan
Display Color touchscreen
StatusLight Yes
Data Connectivity Yes
Large-Container Capability Yes, within 1210 g maximum capacity

Choosing Between a 0.01 g and 0.1 g Precision Balance

The XPE1202S provides 0.01 g readability, giving it ten times finer displayed resolution than a 0.1 g precision balance.

That additional resolution can be valuable when weighing smaller formulation ingredients, reagents, samples, or components where differences of a few hundredths of a gram are significant.

A 0.1 g balance may be preferable when the application involves larger quantities and the additional resolution is unnecessary.

For example, bulk media preparation may not require 0.01 g readability, while formulation development or research sample preparation often benefits from it.

Choosing the correct balance therefore depends on the smallest quantity that must be measured reliably rather than simply selecting the instrument with the highest capacity.

XPE1202S vs. Analytical Balance

The XPE1202S provides finer resolution than many standard precision balances but remains substantially less sensitive than an analytical balance.

A conventional analytical balance typically provides 0.1 mg readability, compared with 10 mg readability on the XPE1202S.

That means an analytical balance provides approximately 100 times finer displayed resolution.

However, analytical balances generally have smaller weighing pans, enclosed weighing chambers, lower maximum capacities, and greater sensitivity to vibration and airflow.

The XPE1202S is better suited for routine sample preparation, formulation, reagent weighing, and larger containers.

An analytical balance is preferable for smaller quantities, standards preparation, gravimetric analysis, and procedures requiring sub-milligram resolution.

Many laboratories benefit from having both types of balances available.

XPE1202S vs. XPE2002S

The XPE1202S and XPE2002S both provide 0.01 g readability and share much of the same Excellence Plus technology.

The principal difference is maximum capacity.

The XPE1202S provides

CLICK HERE to see the Mettler XPE1202S Excellence Plus on our YouTube channel

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.