Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Puffer Hubbard IGL2023A18 – Legacy Freezer Support

Fully Tested & Warrantied*
Brand : Revco
Product Code : SKU 2567A_FREEZER
Sold Out
⚠

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Puffer Hubbard IGL2023A18 – Legacy Freezer Repair, Troubleshooting & Replacement

The Puffer Hubbard IGL2023A18 is a historical upright laboratory freezer previously listed by American Instrument Exchange. This out-of-stock page helps laboratories research the model, troubleshoot common problems and consider replacement equipment. The original unit is not available for purchase.

The historical listing records 23 cu. ft. of capacity. Its historical temperature specification is down to -20°c. Gravity convection air distribution; CFC-free urethane insulation described historically. Historical model designation IGL2023A18; distinguish from explosion-proof Puffer Hubbard SKU 2567P.

Puffer Hubbard IGL2023A18: Original Features and Use

Model-specific identification is essential when servicing aging equipment. Historical model designation IGL2023A18; distinguish from explosion-proof Puffer Hubbard SKU 2567P. Intended laboratory use depends on actual temperature performance, facility procedures and the samples being stored. Do not infer safety or temperature certifications from similar products.

Puffer Hubbard IGL2023A18: Identifying the Exact Model

Document the full model and serial number, electrical nameplate, controller revision and any optional accessories. Closely related model names may use different compressors, wiring or controller parts.

Before ordering components, compare the exact serial range against applicable manufacturer literature. An archived AIE description is useful historical context but not a substitute for the individual nameplate.

Puffer Hubbard IGL2023A18: Common Temperature Alarms

Temperature excursions can result from prolonged access, warm product loading, power interruptions, restricted condenser airflow, degraded seals, sensor drift or refrigeration faults. A high-temperature alarm does not identify a specific failed part.

Compare the displayed temperature against an independent calibrated monitor, preserve event history and check room conditions before making adjustments. If the freezer cannot maintain the required setpoint with doors closed, arrange qualified diagnosis.

Puffer Hubbard IGL2023A18: Door Gaskets and Frost

Inspect the outer seal, hinge alignment, latches and any interior compartment doors for gaps or damage. Moist air entering a cabinet can cause frost buildup, longer recovery times and higher energy use.

Use manufacturer-approved defrost methods. Avoid sharp tools or improvised heaters that could damage insulation, electrical components or hidden refrigerant lines.

Puffer Hubbard IGL2023A18: Airflow and Refrigeration Performance

Blocked ventilation and dusty condenser surfaces can increase compressor duty and reduce cooling performance. Follow the manufacturer's service instructions for accessible cleaning and ventilation clearances.

Refrigerant handling and sealed-system repair require qualified personnel. On obsolete models, parts availability, refrigerant compatibility and the cost of major work should be checked before committing to repair.

Puffer Hubbard IGL2023A18: Controllers and Alarm Monitoring

Check sensor accuracy, high and low alarm settings, remote contacts and backup batteries where fitted. Record controller fault codes and temperature trends before changing settings.

Independent monitoring is particularly important for critical sample storage. Historical features are not guaranteed to be installed or functional on every surviving unit.

Puffer Hubbard IGL2023A18: Preventive Maintenance

Regular maintenance can include inspection of seals, accessible condenser components, airflow clearance and alarm operation. Track cooling recovery after access and document recurring faults.

Maintain a sample inventory, qualified backup storage and a written response plan for temperature excursions. The laboratory must determine sample acceptability under its validated procedures.

Puffer Hubbard IGL2023A18: Repair Feasibility

An isolated gasket, sensor or control problem may be practical to repair if compatible parts exist. Major compressor, insulation or obsolete electronics problems may make replacement more economical.

Compare service costs with downtime, sample risk, efficiency and future supportability. American Instrument Exchange can discuss refurbished replacement options; specific repair services and part availability must be confirmed.

Puffer Hubbard IGL2023A18: Replacement Considerations

Compare required storage temperature, usable shelf and rack dimensions, overall footprint, electrical requirements, ventilation, monitoring and access clearance. Nominal cubic feet alone does not determine sample capacity.

For verified -86°C requirements, AIE's Thermo TSX60086 and TSX70086 are potential newer alternatives subject to availability and suitability. Neither is an equivalent substitute for validated -140°C storage or specialized hazardous-location requirements.

Puffer Hubbard IGL2023A18: Installation and Shipping

Measure the intended location, doorways, floor loading, ventilation and available electrical service. For upright units, account for door swing and access to rear service panels.

Follow manufacturer stabilization and performance qualification procedures before transferring sensitive samples.

Puffer Hubbard IGL2023A18: AIE Legacy Equipment Support

American Instrument Exchange maintains historical listings to help laboratories identify obsolete freezers and compare refurbished equipment. This is an out-of-stock reference, not an offer for the original unit.

When contacting AIE, provide the full model, serial, voltage, required temperature, capacity and observed fault symptoms.

Puffer Hubbard IGL2023A18 Key Specifications

Model Puffer Hubbard IGL2023A18
Historical AIE SKU 2567A
Equipment type Upright laboratory freezer
Nominal capacity 23 cu. ft.
Historical operating temperature Down to -20°C
Original features Gravity convection air distribution; CFC-free urethane insulation described historically
Electrical requirements Verify individual nameplate
Exterior / interior dimensions Verify manufacturer documentation
Availability Out of stock; legacy reference

Specifications compiled from historical American Instrument Exchange product information. Unverified values are not inferred from similar models and must be checked against manufacturer literature and the individual unit.

Frequently Asked Questions About the Puffer Hubbard IGL2023A18

Is this exact freezer currently for sale?

No. This is an out-of-stock historical reference.

What temperature does it support?

The original listing specifies Down to -20°C; confirm actual performance.

What is its storage capacity?

The original record cites 23 cu. ft.; usable storage depends on shelf or rack configuration.

Can it be repaired?

Possibly, depending on its diagnosed fault, condition and available parts.

Why is the freezer warming?

Possible causes include door seals, loading, airflow, power, sensors or refrigeration faults.

Why is frost accumulating?

Moist air entering through damaged or poorly seated seals is one common cause.

Can existing racks be reused?

Only after comparing rack dimensions with the replacement's interior.

When is replacement preferable?

Consider recurring failures, unsupported parts, downtime and sample risk.

Does AIE offer replacement freezers?

AIE sells refurbished laboratory equipment; verify current availability.

What details should I supply for troubleshooting?

Full model and serial number, voltage, temperature logs and fault history.

Discuss Puffer Hubbard IGL2023A18 Replacement Options

Contact American Instrument Exchange with the complete model, serial number, storage requirements and installation constraints to compare suitable refurbished alternatives.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.